Skip to content

Thrive Health and Wellness LLC Form 483, April 2025

FDA issued this Form 483 to Thrive Health and Wellness LLC in Englewood, Colorado (FEI 3033176989) at the end of a drug inspection that ended April 3, 2025. It lists 6 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on February 9, 2026.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted May 7, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 3, 2025
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
May 7, 2025
34 days after the inspection
Facility
FEI 3033176989
Englewood, Colorado

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    No certified ISO-5 area for sterile compounding

    Lack of a certified ISO-5 classified area for sterile compounding Specifically, Your firm fills syringes intended for subcutaneous injection by withdrawing sterile solution from vials on a benchtop table, located in an unclassified room for the following products: • Semaglutide for injection • Tirzepatide for injection • Cyanocobalamin for injection • Lipoboost (B-complex) for injection • Sermorelin for injection The dosage of each product varies among patients or across different treatment levels. Your firm produced an average of approximately (b) (4) syringes a week. For example, on 3/24/2025, your firm produced approximately (b) (4) syringes of GLP-1 Semaglutide injections: Level 4 (1.7 mg/5mg/mL), Lot# 03075J, Discard by: 7/7/2025 and GLP-2 Tirzepatide: Level 4 (10 mg /30mg/ml), Lot# 03125A, Discard by: 9/12/2025. These syringes have been dispensed to patients. Additionally, your firm assigned the beyond-use dates (BUDs) or discard-by date to all repackaged syringe products, which are the same as those of the original vials used for filling despite the lack of a certified ISO-5 classified area for repackaging syringes intended to be sterile. For example, the finished syringes of Tirzepatide for injection were assigned BUDs identical to those of the multi-dose vial used for filling. Two lots of syringes containing Tirzepatide injection produced on 3/24/2025 (Lot #03075J and Lot #03125A), were assigned BUDs of 7/7/2025, and 9/12/2025, respectively, which are identical to those of the two vials used for filling those syringes.

  2. 2

    No media fills for aseptic operations

    Failures to conduct media fills that simulate aseptic production operations. Specifically, The operators involved in repackaging vials into syringe products intended to be sterile have never conducted media fills. For example, on 3/25/2025, it was observed that the operator produced Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL (5mL), Lot# 03065F, BUD: 7/6/2025; however, the operator has never conducted media fills. Your firm produced approximately (b) (4) syringes a week.

  3. 3

    Unsuitable cluttered production area with carpet

    Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, Your firm filled the syringes containing products intended to be sterile on a benchtop table in an unclassified room that contains potential contaminants, as described below. A. The benchtop table with shelves is cluttered with syringes, containers, utensils, binder clips, wipes, marker pens, and other supplies. B. The room also serves as an office, equipped with a computer, chair, and telephone, and is congested with cardboard boxes, a storage cabinet, wall-mounted artwork, a refrigerator, and various other items. C. The floor is covered with carpet, which makes cleaning difficult.

  4. 4

    Use of non-sterile gloves observed

    Personnel engaged in aseptic processing were observed wearing non-sterile gloves. Specifically, Your firm uses non-sterile gloves in the production area. For example, on 3/25/2025, the operator was observed using non-sterile gloves during the filling of syringes of Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL, Lot# 03065F, BUD: 7/6/2025, from a vial.

  5. 5

    Inadequate disinfection and no sporicidal agents

    Use of a disinfectant in a manner insufficient to achieve adequate levels of disinfection. Specifically, A. Sporicidal agents are not used in the production area. Your firm uses non-sterile wipes and a multi-enzymatic cleanser to clean the production area and utensils. Sporidical agents have never been used, and none are available at your facility. B. Your firm uses non-sterile disinfecting wipes to clean the production area. No sterile wipes intended for cleaning work surfaces were available at your firm. C. The work surface is not disinfected prior to packaging vials into syringes. For example, on 3/25/2025, during the filling of syringes of Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL, Lot# 03065F, BUD: 7/6/2025, from a vial, the operator failed to disinfect the work surfaces with appropriate wipes prior to use.

  6. 6

    Exposed hair and skin without gowning

    Personnel engaged in aseptic processing were observed with exposed hair and skin. Specifically, No gowns, head covers, or masks were used during the filling of syringes intended to be sterile. For example, on 3/25/2025, the operator, with exposed hair, did not wear any gown during the filling of syringes with Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL (5mL), Lot# 03065F, from a vial.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.