Skip to content

Thrive Health and Wellness, LLC

88 Inverness Cir E Unit A204, Englewood, Colorado, United States

FEI 3033176989

FDA has one inspection on file for Thrive Health and Wellness, LLC in Englewood, Colorado (FEI 3033176989). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2025
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jun 21, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No certified ISO-5 area for sterile compounding

      Lack of a certified ISO-5 classified area for sterile compounding Specifically, Your firm fills syringes intended for subcutaneous injection by withdrawing sterile solution from vials on a benchtop table, located in an unclassified room for the following products: • Semaglutide for injection • Tirzepatide for injection • Cyanocobalamin for injection • Lipoboost (B-complex) for injection • Sermorelin for injection The dosage of each product varies among patients or across different treatment levels. Your firm produced an average of approximately (b) (4) syringes a week. For example, on 3/24/2025, your firm produced approximately (b) (4) syringes of GLP-1 Semaglutide injections: Level 4 (1.7 mg/5mg/mL), Lot# 03075J, Discard by: 7/7/2025 and GLP-2 Tirzepatide: Level 4 (10 mg /30mg/ml), Lot# 03125A, Discard by: 9/12/2025. These syringes have been dispensed to patients. Additionally, your firm assigned the beyond-use dates (BUDs) or discard-by date to all repackaged syringe products, which are the same as those of the original vials used for filling despite the lack of a certified ISO-5 classified area for repackaging syringes intended to be sterile. For example, the finished syringes of Tirzepatide for injection were assigned BUDs identical to those of the multi-dose vial used for filling. Two lots of syringes containing Tirzepatide injection produced on 3/24/2025 (Lot #03075J and Lot #03125A), were assigned BUDs of 7/7/2025, and 9/12/2025, respectively, which are identical to those of the two vials used for filling those syringes.

    2. Observation 2

      No media fills for aseptic operations

      Failures to conduct media fills that simulate aseptic production operations. Specifically, The operators involved in repackaging vials into syringe products intended to be sterile have never conducted media fills. For example, on 3/25/2025, it was observed that the operator produced Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL (5mL), Lot# 03065F, BUD: 7/6/2025; however, the operator has never conducted media fills. Your firm produced approximately (b) (4) syringes a week.

    Show observations 3 to 6
    1. Observation 3

      Unsuitable cluttered production area with carpet

      Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, Your firm filled the syringes containing products intended to be sterile on a benchtop table in an unclassified room that contains potential contaminants, as described below. A. The benchtop table with shelves is cluttered with syringes, containers, utensils, binder clips, wipes, marker pens, and other supplies. B. The room also serves as an office, equipped with a computer, chair, and telephone, and is congested with cardboard boxes, a storage cabinet, wall-mounted artwork, a refrigerator, and various other items. C. The floor is covered with carpet, which makes cleaning difficult.

    2. Observation 4

      Use of non-sterile gloves observed

      Personnel engaged in aseptic processing were observed wearing non-sterile gloves. Specifically, Your firm uses non-sterile gloves in the production area. For example, on 3/25/2025, the operator was observed using non-sterile gloves during the filling of syringes of Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL, Lot# 03065F, BUD: 7/6/2025, from a vial.

    3. Observation 5

      Inadequate disinfection and no sporicidal agents

      Use of a disinfectant in a manner insufficient to achieve adequate levels of disinfection. Specifically, A. Sporicidal agents are not used in the production area. Your firm uses non-sterile wipes and a multi-enzymatic cleanser to clean the production area and utensils. Sporidical agents have never been used, and none are available at your facility. B. Your firm uses non-sterile disinfecting wipes to clean the production area. No sterile wipes intended for cleaning work surfaces were available at your firm. C. The work surface is not disinfected prior to packaging vials into syringes. For example, on 3/25/2025, during the filling of syringes of Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL, Lot# 03065F, BUD: 7/6/2025, from a vial, the operator failed to disinfect the work surfaces with appropriate wipes prior to use.

    4. Observation 6

      Exposed hair and skin without gowning

      Personnel engaged in aseptic processing were observed with exposed hair and skin. Specifically, No gowns, head covers, or masks were used during the filling of syringes intended to be sterile. For example, on 3/25/2025, the operator, with exposed hair, did not wear any gown during the filling of syringes with Tirzepatide/ Cyanocobalamin, 15mg/1mg/mL (5mL), Lot# 03065F, from a vial.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jun 21, 2025. Each one asked for a Form 483.

  • Inspection ending Apr 3, 2025OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jun 21, 2025FDA-FOIA-2025-7919Form 483· 1 of 10 sitesRecords released
    2. May 13, 2025FDA-FOIA-2025-4353Form 483· 1 of 5 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3033176989 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3033176989. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.