Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Rechon Life Science ABInspection ended Sep 6, 2024 · FEI 3002806978 · Observation 2
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. 1. Your firm failed to continuous monitoring HEPA air velocity in critical areas to decrease contamination risk and ensure aseptic processing line suitability. For example: A. Aseptic connection of bulk solution tank in Line (b) (4) Vials (b) (4) is performed in a Grade A area without …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Rechon Life Science ABInspection ended Sep 6, 2024 · FEI 3002806978 · Observation 3
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Your procedure SOP 2181 version 2.0, Effective date: 2023-11-09 (b) (4) Dekontaminering av lokaler på Bulk Production (b) (4) Sanitization - Decontamination of rooms at Bulk Production" for the (b) (4) decontamination and sanitization of Grade A and Grade B production areas using (b) (4) (b) (4) is inadequate. …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →
Rechon Life Science ABInspection ended Sep 6, 2024 · FEI 3002806978 · Observation 4
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Risk Assessment Report QGL-1015-02 titled "Identification of critical monitoring locations for viable and non-viable particles on the ampoule filling line", approved on 04/02/2024, justifies the environmental monitoring locations of ampoule filling line. On 08/26/2024, during our assessment of the filling line assembly operations for the …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Rechon Life Science ABInspection ended Sep 6, 2024 · FEI 3002806978 · Observation 6
Your firm failed to maintain buildings used in the manufacture, processing, packing or holding of drug products in a good state of repair. During the walking tour of your aseptic processing areas, the walls of the production Rooms (b) (4) and (b) (4) and the floor of the Room (b) (4) in the Grade D aseptic areas were observed to be sticky to the touch. This condition suggested inadequate cleaning and maintenance practices within the controlled …
Contains “aseptic*”Read the Form 483 →
Nubratori, IncInspection ended Jul 26, 2024 · FEI 3010166491 · Observation 1
Procedures designed to prevent microbiological contamination did not include adequate validation of the aseptic process. Specifically, A. You do not perform growth promotion studies [(b) (4] for your Media Fills and therefore [illegible] of gram-positive, gram-negative bacteria, yeast, and mold. B. Your firm has not performed product [illegible] Preservative Free using the final distributed container 2mL amber vials, however, all product …
Contains “aseptic*”Read the Form 483 →
Nubratori, IncInspection ended Jul 26, 2024 · FEI 3010166491 · Observation 2
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On 07/17/2024, during the production of Lidocaine HCl/Tetracaine HCl (Lot#[(6 ) I observed that the technician collect their glove fingertip personnel monitoring samples, after wiping a piece sampling equipment with Sterile[(b) (4)], and samples were not taken immediately after completion of aseptic operations. Personnel monitoring …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Nubratori, IncInspection ended Jul 26, 2024 · FEI 3010166491 · Observation 3
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, On 07/17/2024, during the production of Lidocaine HCl/Tetracaine HCl (Lot#[(b) (4)] I observed that the operator failed to wipe down the ISO 7 side [(6) (4)] before opening it to receive materials and failed to clean the legs of the ISO 5 [(6) (4)] air flow hood before aseptic operations.
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →
Hikma Pharmaceuticals USA Inc.Inspection ended Jun 12, 2024 · FEI 2220525 · Observation 1
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and followed. Specifically, your air visualization "smoke" studies, TestProtCHH15017 Protocol to Perform Smoke Profile in Room 115 and TestProtCHH15372 Protocol to Perform Smoke Study In Room 115 for Machine Adjustments utilized by your firm to qualify your controlled environment revealed deficiencies. For example: A. In …
Contains “smoke stud*”Read the Form 483 →
GSK Vaccines GmbHInspection ended Mar 6, 2024 · FEI 3001314775 · Observation 1
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, a. On 2/26/2024 during (b) (4) operation of MenA Vaccine batch (b) (4) using (b) (4) unit, and after exchanging (b) (4) located approximately (b) (4) vials, the grade(b)(4) operators did not reject the (b) (4) product vials located directly below the intervention. As per your SOP instruction# …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Jiangsu Hengrui Pharmceuticals Co., LtdInspection ended Jan 16, 2024 · FEI 3007373503 · Observation 1
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, A) Product contact equipment including (b)(4), topper drums, (b)(4) were sterilized without proper capping and transferred from a Grade A Cart to inside of the RABS without cover in Workshop (Filling Room (b)(4)). There were no physical separations …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Jiangsu Hengrui Pharmceuticals Co., LtdInspection ended Jan 16, 2024 · FEI 3007373503 · Observation 2
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product. Specifically, Your container closure integrity test for (b)(4) Injection (USP) (b)(4) is inadequate. The test used empty vials instead of filled vials. Microbial Challenge Study was conducted without a positive control. Dye ingress study was conducted using human …
Contains “container closure integrity”Read the Form 483 →
Jiangsu Hengrui Pharmceuticals Co., LtdInspection ended Jan 16, 2024 · FEI 3007373503 · Observation 6
… Upon arrival, we were told to wait until personnel gowned and entered the cleanroom to show us the interface for the equipment. Approximately twenty (20) minutes later, your personnel came inside our non-classified area with the MET ONE 3400 equipment in hand, your firm stating that he had misunderstood our request and brought the equipment out of the cleanroom. Upon review, we observed the interface, which read "USB Flash Drive Not Installed" …
Contains “gown*”Read the Form 483 →
Jiangsu Hengrui Pharmceuticals Co., LtdInspection ended Jan 16, 2024 · FEI 3007373503 · Observation 8
Washing and toilet facilities lack hot and cold water. Specifically, During the inspection of your (b)(4) parenteral drug product workshop (b)(4) we observed that is no hot/warm water in the washing facility prior to the entrance of the Clothes Sterilization room Grade D on 01/11/2024. Additionally, our workshop manager confirmed that there is no warm/hot water at any of the hand washing stations for the entire workshop, including the washing …
Contains “sterili*”Read the Form 483 →
Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 3
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. The designs of Vial Line [illegible] systems (6 4 ), Vial Line (4) system, Flexible Fill Line (6) (4), Syringe Line (6)(4) (b) (4), and Syringe (6) (4) system do not allow all (6) (4) to be (6) (with [illegible]). These include, but are not limited to, the following: • …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Catalent Indiana, LLCInspection ended Nov 15, 2023 · FEI 3005949964 · Observation 4
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in process material and the drug product. Specifically, For visual inspection of drug products and biological drug products purporting to be sterile, operators are qualified on Kt>) (4I vials; doing so allows operators to inspect [6) (4) I, and t>f …
Contains “purporting to be sterile”Read the Form 483 →
Synergy Health Ede BVInspection ended Oct 12, 2023 · FEI 3020976354 · Observation 1
Procedures for changes to a process have not been adequately established. Specifically, the process treatment [illegible] factor for xray sterilization in the Venlo facility was changed from [illegible] reportedly on September 11, 2023. The change was not documented and approved in the change control system.
Contains “sterili*”Read the Form 483 →
Sanofi PasteurInspection ended Sep 29, 2023 · FEI 3002972083 · Observation 5
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, While observing sterile (b)(4) operations for Imovax Rabies batch X1C16 (US Market) on (b)(4) line within the (b)(4) manufacturing building on September 25, 2023, it was observed that (b)(4) operators [illegible] in Rooms (b)(4) and (b)(4) [illegible] did not utilize aseptic best practices to limit disruption …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 1
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, 1) Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted. On 8/22/2023, in the sterile filling hood, your technician was producing Pentosan Glucosamine batch 520880. During aseptic filling your technician and/or pharmacist was observed …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 2
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic or sterilization process. Specifically, 1) Your media fills do not include any high-risk challenges and are performed during "routine" operations. a) On 8/22/23, during aseptic filling of Pentosan Glucosamine batch 520880, your technician changed out a glove on the ISO-5 (b) (4), however, glove …
Contains “purporting to be sterile”Read the Form 483 →
Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 3
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, On 9/7/2023, during aseptic filling of Reserpine 2.5mg/mL, brown residue was wiped off the bottom of vials that were introduced to the sterile hood for filling. Reserpine is a clear/yellow liquid. More than 9 vials were discarded …
Contains “aseptic*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.