Skip to content

Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 4

    … (b) (4) additional batch of Estrone 5mg/mL, lot 504414, was produced after initial potency but was not released due to a sterility failure.

    Contains “sterili*”Read the Form 483 →

  2. Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 5

    … did not determine a root cause or investigate batches that failed during visual inspection for leaking vials due to excessive seals popping off during (b) (4) sterilization. Your firm has rejected two batches in the past year due to seals leaking. On 7/5/23, Estradiol 2mg/mL lot 511677 was rejected due to excessive vial seals popping off. On 8/4/23, Altrenogest 110mg/mL lot 517601 was rejected due to excessive vial seals popping off. 2) Your firm …

    Contains “sterili*”Read the Form 483 →

  3. Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 2

    Written production and process control procedures are not followed, established, or are deficient. Specifically, A) On 25 August 2023, observed for Plant (b) (4) RABS Fill Line (b) (4) Batch #(b) (4) was the transition of the (b) (4) stopper bowl from Grade B space into the Grade A RABS. Furthermore, observed was the transition of a (b) (4) system from Grade B space to the Grade A RABS, where the (b) (4) bag was opened in Grade B space, with the …

    Contains “RABS”Read the Form 483 →

  4. Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 3

    … removal of jammed vials at the (b) (4) and the removal, adjustment/maintenance, and re-installation of the (b) (4) (b) (4) have not been evaluated as part of smoke studies. B) Fill Line (b) for (b) (4) drug product manufacture includes a (b) (4) vial conveying system, where (b) (4) vials filled with drug product can be filled and pending stoppering during a line stoppage. There is no procedure or HMI limitation for how long product filled vials …

    Contains “smoke stud*”Read the Form 483 →

  5. Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 4

    … B) (b) (4) 230-(b) (4)-5311 used in Plant (b) for (b) (4) sterilization of equipment and components for Fill Line (b) includes a (b) (4) supplied with (b) (4) with the last (b) (4) sterilization process validated both physically and biologically, June 2020. The (b) (4) is not revalidated on a routine basis in assurance the validated state is maintained.

    Contains “sterili*”Read the Form 483 →

  6. Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 5

    … extend the investigation to other personnel involved in the filling of this drug to ensure the interventions performed by other personnel did not impact the sterility of the drug product. Additionally, during the inspection, we observed that personnel monitoring is not performed according to your procedure. See OBSERVATION 2C.

    Contains “sterili*”Read the Form 483 →

  7. Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 6

    Facilities are not adequately maintained. Specifically, A) On 25 August 2023, observed was a ceiling port cover dislodged in Grade B space, directly over where Plant (b)(4) (Fill Line (b)(4) RABS (b) (4) open. The condition was observed during fill line setup for manufacture of (b) (4) Batch #(b) (4) B) On 21 August 2023, observed within the GMP warehouse, Solid Waste Collection WI-1130 was a door leading to the outside, with the door bottom …

    Contains “RABS”Read the Form 483 →

  8. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 2

    … SOP QC-868-009, The Determination of Microbiological Experiment Result, does not assure that the (b) (4) will not be disrupted during the (b) (4) reads of the sterility test samples. The procedure requires, "observe (b) (4) during incubation, remove medium from the incubator, observe whether the medium is (b) (4) in a well-lit place, and (b) (4) the medium if necessary". b) On 15 August 2023, microbiologists performing the (b) (4) reads of …

    Contains “sterili*”Read the Form 483 →

  9. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 4

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, a) Not all locations on Workshop (b) (4) filling line, used for filling products (b) (4) Injection and (b) (4) Suspension, shows adequate air flow without turbulence during smoke studies. 1) The (b) (4) area next to the Workshop (b) (4) filling line with Grade A airflow is used for opening the LAF (b) (4) …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  10. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 5

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, a) Filling of (b) (4) Suspension in Workshop (b) (4) uses dedicated, (b) (4) product contact (b) (4) tubing during filling operations. The (b) (4) tubings are required to be replaced (b) (4) (b) (4) Media simulation studies in Workshop (b) (4) s performed with (b) (4) tubing, instead of (b) (4) tubing used to …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  11. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 6

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) Operators performing critical (b) (4) interventions on aseptic filling lines in Workshops (b) (4) and (b) (4) are not monitored after completing the intervention on the Grade A filling line. For example, 1) SOP #PO-3 112 005-012, SOP for Filling Operations of Workshop (b) (4) does not require monitoring of gloved hands after each …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  12. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 8

    … b) The Grade A filling line in Workshop (b) (4) used for filling (b) (4) Injection, utilizes product dedicated (b) (4) tubing attached to (b) (4). The tubing sets can be used for (b) (4) filling operations or within (b) (4) On 15 August 2023, two sets of dedicated filling tubes were found not uniquely identified as two sets were found with the same tubing identification, both coming from the same master tube roll.

    Contains “Grade A”Read the Form 483 →

  13. Jiangsu Hengrui Pharmaceuticals CO. LTD.Inspection ended Aug 29, 2023 · FEI 3003404148 · Observation 9

    … The (b) (4) had labels that documented number of uses, (b) (4) installation, (b) (4) model, batch number, replacement date, sterilization frequency, operator, and reviewer. After each use of the tank, the identification card on the (b) (4) with the above information is discarded and not documented elsewhere. b) Workshop (b) (4) used for manufacturing (b) (4) Tablets has a tablet compression machine (Model (b) (4) that has no printing function for …

    Contains “sterili*”Read the Form 483 →

  14. Ipca Laboratories LimitedInspection ended Jun 23, 2023 · FEI 3007574780 · Observation 7

    Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform. Specifically, personal gowning used in the compression areas is not maintained clean (b) (4) inspection of Dispensing Room and Compression Area used in the respective area appeared worn out and torn (with holes measuring more than 2 inches). It appeared soiled with black, white, (b) (4). In the core …

    Contains “gown*”Read the Form 483 →

  15. Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 1

    Procedures designed to prevent microbiological contamination of drug product purporting to be sterile are not followed. Specifically, a. The process simulations do not represent actual production operations for your sterile API in Unit (b) (4) of Workshop (b) (4) APIs filled in Unit (b) (4) (Sterile (b) (4) and Sterile (b) (4) are used to manufacture sterile injectable products distributed to the U.S. market. (b) (4) Sterile (b) (4) batches were …

    Contains “purporting to be sterile”Read the Form 483 →

  16. Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 2

    Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination might occur during production. a. Smoke studies performed in Unit (b) (4) of Workshop (b) (4) do not demonstrate airflow without turbulence. The filling line was used to fill (b) (4) batches of (b) (4) product (b) (4) Injection. For example, i. The dynamic smoke study videos showed the (b) (4) of vials, vials traveling on the vial track …

    Contains “smoke stud*”Read the Form 483 →

  17. Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a. Monitoring of nonviable particles on Unit (b) (4) filling line of Workshop (b) (4) is not located within (b) (4) of the vial track where (b) (4) vials move towards the (b) (4) The point where vials turn left towards the (b) (4) is monitored by an online nonviable particle port that is located (b) (4) from the vial track. b. …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  18. Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 4

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, a. Sterility testing of sterile injectable products distributed to the U.S. market requires determination of microbial growth in (b) (4) canisters. There is no requirement to document a check for the (b) (4) for …

    Contains “sterili*”Read the Form 483 →

  19. Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 5

    The responsibilities and procedure applicable to the quality control unit are not in writing. Specifically, Your firm does not have established training procedures to oversee the initial and requalification of aseptic filling operators and visual inspection personnel for workshop (b) (4) units (b) (4) A. Your firm has one SOP titled QUAL116.P "Training for Manufacturing and Quality System Personnel" governing the training program in workshop (b) …

    Contains “aseptic*”Read the Form 483 →

  20. Apicore Pharmaceuticals Private Ltd.Inspection ended May 5, 2023 · FEI 3006767695 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. Your firm manufactures (b)(4) batch calculated that one batch of (b)(4) product vials. Media fill study # MF/CPMD/22/04/01, conducted in May 2021 and simulating the manufacture of sterile (b)(4) [(b)(4) simulation, and [illegible] CFU bacteria such as Bacillus subtilis, …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.