Apicore Pharmaceuticals Private Ltd. Form 483, May 2023
FDA issued this Form 483 to Apicore Pharmaceuticals Private Ltd. in Vadodara, India (FEI 3006767695) at the end of a drug inspection that ended May 5, 2023. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 26, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 5, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 26, 2024
- 571 days after the inspection
The 2 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate aseptic process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. Your firm manufactures (b)(4) batch calculated that one batch of (b)(4) product vials. Media fill study # MF/CPMD/22/04/01, conducted in May 2021 and simulating the manufacture of sterile (b)(4) [(b)(4) simulation, and [illegible] CFU bacteria such as Bacillus subtilis, Bacillus pumilus, Bacillus oceanisediminis, megaterium, were isolated from the recovered CFUs. In three consecutive media fills, your firm performed only one repeat media fill. B. Your firm uses disinfectants to disinfect your facility and equipment, including surfaces that come into contact with the sterile API manufactured by your firm. Review of your disinfectant efficacy study (Protocol #s ACP-22-01 [illegible]) showed that the study was performed by pipetting [a volume] of the test culture on the coupon and allowing it to dry, followed by pipetting about [illegible] of the disinfectant over the dried culture. This method of disinfecting is different than your routine disinfecting procedure (APV-SOP-MFG253) wherein the disinfectant is sprayed or wiped using a lint free cloth.
- 2
Incomplete calibration range verification
Routine calibration of electronic equipment is not performed to assure proper performance. Specifically, Analytical balance QCE #684 with a weight range of 20 mg to 200 g is used in your firm's QC chemistry laboratory to weigh test samples. Your firm's verification of this balance includes only the 50 mg to 200 g weight range, and does not include the lower weight range of 20 mg to 50 mg.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.