Apicore Pharmaceuticals Private Ltd
Block No 252-253, Village-Dhobikuva, Opposite Jain Irrigation, Vadodara, India
FEI 3006767695DUNS 676248879
FDA has 6 inspections on file for Apicore Pharmaceuticals Private Ltd in Vadodara, India (FEI 3006767695), from 2011 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
2 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, analysis, sterilization, relabeling and repacking, through Dec 31, 2026. Its registrant is APICORE PHARMACEUTICALS PRIVATE LIMITED (D-U-N-S 676248879).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2011–2023
- 0 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 6
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Nov 15, 2024
- Warning letters
- None on file
- Import refusals
- 2 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. Your firm manufactures (b)(4) batch calculated that one batch of (b)(4) product vials. Media fill study # MF/CPMD/22/04/01, conducted in May 2021 and simulating the manufacture of sterile (b)(4) [(b)(4) simulation, and [illegible] CFU bacteria such as Bacillus subtilis, Bacillus pumilus, Bacillus oceanisediminis, megaterium, were isolated from the recovered CFUs. In three consecutive media fills, your firm performed only one repeat media fill. B. Your firm uses disinfectants to disinfect your facility and equipment, including surfaces that come into contact with the sterile API manufactured by your firm. Review of your disinfectant efficacy study (Protocol #s ACP-22-01 [illegible]) showed that the study was performed by pipetting [a volume] of the test culture on the coupon and allowing it to dry, followed by pipetting about [illegible] of the disinfectant over the dried culture. This method of disinfecting is different than your routine disinfecting procedure (APV-SOP-MFG253) wherein the disinfectant is sprayed or wiped using a lint free cloth.
- Observation 2
Incomplete calibration range verification
Routine calibration of electronic equipment is not performed to assure proper performance. Specifically, Analytical balance QCE #684 with a weight range of 20 mg to 200 g is used in your firm's QC chemistry laboratory to weigh test samples. Your firm's verification of this balance includes only the 50 mg to 200 g weight range, and does not include the lower weight range of 20 mg to 50 mg.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Nov 15, 2024. It asked for a Form 483.
Inspection ending May 5, 2023VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Nov 15, 2024FDA-FOIA-2024-10163Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3006767695, one row per refused product line.
2 refusals from 2018-03-29 to 2020-11-25 · charged NOT LISTED on 2, UNAPPROVED on 2 · no FDA sample analysis
FDA firm profile- 2020-11-25
COLESTIPOL HCL (ANTI-HYPERLIPIDEMIC)62BCS04
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-0008537-3/11/1
- 2018-03-29
DISULFIRAM (ALCOHOL DETERRENT)60GIY01
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-4774945-0/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis, sterilization, relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- APICORE PHARMACEUTICALS PRIVATE LIMITEDD-U-N-S 676248879
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006767695 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006767695. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.