Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 12
… (b) (4) (b) (4) The acceptance criteria include for example, (b) (4) (b) (4) The airflow visualization studies (video) document numerous instances where the unidirectional airflow and the personnel's manual operations impact upon the airflow that could not be observed due to either the angle and position of the video camera, or due to an obstructed view caused by the filling equipment and/or due to a lack of smoke over the production personnel's …
Contains “unidirectional*”Read the Form 483 →
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 13
There are individual Air Flow Visualization Study & Recovery Studies performed for the aseptic fill lines, the UAF units, (b) (4) and the microbiology sterility tests areas in (b) (4) (b) (4) that have been reviewed and approved by personnel from IPQA, Maintenance, Production and Validation Departments. However, as confirmed by the individuals who reviewed and approved the air flow visualization studies there are no written evaluations regarding …
Contains “aseptic*”Read the Form 483 →
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 14
There is a (b) (4) in aseptic fill line (b) (4) that is used by personnel to move from the fill room to the (b) (4) area and capping station. The Intervention Trend Report for Vial Filling Line (b) (4) (b) (4) from 01 Feb 2022 to 31 Jul 2022, dated 16 Sep 2022, document that the minimum & maximum number of intervention occurrences consisted of 07 and 37 times, respectively during the manufacturing processes. The Intervention Trend Report for Vial …
Contains “aseptic*”Read the Form 483 →
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 15
As previously reported in the preceding observation, production personnel access the aseptic fill line (b) (4) (b) (4) via the (b) (4) RABS access panel [e.g., (b) (4)] that is approximately (b) (4) (b) (4). The body movements performed by the production operator to enter and exit the Grade A environment have a direct impact upon the unidirectional air flow. There is no air flow evaluation regarding the above production personnel activity to …
Contains “aseptic*”Read the Form 483 →
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 16
As confirmed by the Assistant General Manager Project & Engineering Department, there are no Architectural Layouts (As Build) engineering diagrams for the HVAC units in (b) (4) manufacturing facilities. In addition, a. There is not Architectural Layouts for the (b) (4) Restricted Access Barrier System ((b) (4) RABS) that is used to aseptically manufacture (b) (4) finished drug products in the (b) (4) aseptic fill line in (b) (4) (b) (4) or for …
Contains “RABS”Read the Form 483 →
QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 1
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A) No documented review was performed when mold was recovered on an operator (b) (4) plate sample taken on 06/29/2022 after ISO 5 operations in Clean Room (b) (4) and the clean room experienced elevated temperature and relative humidity excursions beyond the set alarm points. This mold recovery on 06/29 was the …
Contains “ISO 5”Read the Form 483 →
QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 2
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, Your firm's environmental and personnel monitoring program does not include sampling of all potential routes of microbial contamination. For example: A) On 08/16/2022, during our observation of sterile filling of Epinephrine, Preservative Free (PF), 10mcg/ml in 10ml Dextrose 5% in (b) (4) (D5W) Syringe, Lot# (b) (4), Expiration Date: …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 4
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A) During review of user access rights for the (b) (4) (Equipment ID: (b) (4) (b) (4)), in Building (b) (4) which are used to test the (b) (4) of the (b) (4) used to sterilize in process bulk, it was observed that all operators access …
Contains “sterili*”Read the Form 483 →
QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 5
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. Specifically, A) Smoke studies conducted on 09/08-09/10/2021 in the ISO 5 (b) (4) syringe filler (Equipment ID: NJ (b) (4)-(b) (4)) and on 02/24/2022 in the ISO 5 LAF Hood (Equipment ID: NJ-LAF-(b) (4)) are inadequate. Specifically, during the smoke studies, the (b) (4) system was not turned on during dynamic …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
First Royal Care Co. LLC, dba Red Mountain CompoundingInspection ended Sep 12, 2022 · FEI 3015235235 · Observation 1
OBSERVATION 1: ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions. You never performed any dynamic smoke studies for your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. In addition, on 09/01/22, …
Contains “ISO 5”Read the Form 483 →
First Royal Care Co. LLC, dba Red Mountain CompoundingInspection ended Sep 12, 2022 · FEI 3015235235 · Observation 2
OBSERVATION 2: The ISO 5 classified equipment has difficult to clean surfaces. Specifically, I observed the back panel of your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. On 09/01/22, your Lead Sterile Technician stated the (b)(6)(b)(4) is used to cover the mounting holes for (b)(6)(b)(4) …
Contains “ISO 5”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 1
… particle found in the (b)(4) on the (b)(4) motor in Zone (b) which lies above the filling line where filling takes place and units are unstoppered during aseptic filling of (b)(4) lot (b)(4) dated 4/28/22. Particle was identified as (b)(4) with (b)(4) material. (b)(4) is not used in the manufacturing of lot (b)(4). (b)(4) is within the formulation of (b)(4) lot (b)(4) which was manufactured directly before this batch. The investigation states, …
Contains “aseptic*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 5
… Your firm has an ongoing issue of (b)(4) integrity issues that are involved in low and high-risk aseptic interventions during the aseptic filling of sterile drugs. Your firm performed a Deviation Trending Investigation for Building (b)(4) on February 9, 2022 and determined the root cause to be the (b)(4) material was not robust enough to maintain integrity during use. Your firm initiated corrective action to remediate the issue to related (b)(4) …
Contains “aseptic*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 6
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, or followed. A. The airflow studies demonstrate a number of instances that document a lack of successfully meeting the acceptance criteria. For example, A-VPQ-00178-S-VL-070MAR21 Vial Filling (b)(4) (System 3400) Static and Dynamic Airflow Visualization Study Summary Report, v0, dated 5/10/21 establishes the …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 8
Your firm failed to establish and follow adequate control procedures to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. The following discrepancies were noted during the review of visual inspector qualification for aseptic filling: A. Although included in the emulsion visual inspection kit, visual …
Contains “aseptic*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 9
In-process samples are not representative. Specifically, There is no scientific justification for not performing particles testing on routinely inspected product. Batches of aseptically filled (b)(4) are inspected by (b)(4). The particulate defects are rejected and the "ejects" are run through the (b)(4) (b)(4) for additional inspection. Instead of performing destructive particles testing on the good vials remaining after the (b)(4) inspection, …
Contains “aseptic*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 10
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. A. The material (b)(4) for vial filler (b)(4) has not been qualified for LIMS labels. Deviation 493708 dated 2/25/22 was initiated due to action levels being obtained on an (b)(4) in vial line (b) between the (b)(4) and the conveyor. The root cause determined the validation requirements …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 12
… A-SOP-09-01-061, (b)(4) Inspection of Media Filled Vials, v9, dated 12/13/21 states to (b)(4) (b)(4) the containers for approximately (b)(4) prior to inspection to suspend any potential microbial growth. (b)(4) the vial prior to initial review could potentially disperse the microbial film on the surface of the media if it existed. C. On 8/1/22 during the walk-through inspection of the Microbial Testing Laboratory, air bubbles were observed …
Contains “media fill*”Read the Form 483 →
Carolina InfusionInspection ended Aug 12, 2022 · FEI 3015826782 · Observation 2
Your media fills were not performed under the most challenging or stressful conditions. Specifically, there is a lack of assurance that your firm can aseptically produce under the conditions used in your facility. Your firm utilizes a media fill kit for more complex preparations during sterile compounding. Injectable was produced on 06/08/2022.
Contains “media fill*”Read the Form 483 →
Carolina InfusionInspection ended Aug 12, 2022 · FEI 3015826782 · Observation 3
ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow in the ISO-5 hood in the compounding cleanroom was not verified under operational conditions during the certification performed on June 25, 2022. This hood is used by personnel in the production of sterile drug products, including products intended for intrathecal injection. Intrathecal parenteral preparations include bupivacaine, morphine, …
Contains “ISO 5”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.