Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. AnazaoHealth CorporationInspection ended Jul 29, 2022 · FEI 3011152407 · Observation 1

    The quality unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred. Specifically, the firm has not been reviewing sterility test data packets from their contract testing laboratory for all drug products produced as part of their batch release process for the (b) (4) Suite since January 20, 2015 and for the (b) (4) Suite built in August 2020. Examples of drug …

    Contains “sterili*”Read the Form 483 →

  2. AnazaoHealth CorporationInspection ended Jul 29, 2022 · FEI 3011152407 · Observation 3

    … B) sterility failure identified by Event 2022-0788 during production of (b) (4) Nutrient Cocktail, Batch (b) (4), 50 mL vials, using (b) (4) as per (b) (4) (b) (4) Received Date 5/13/2022 has not been completed in a timely manner and is under investigation. This investigation must assess the hazards of the aseptic filling operation and determine whether other batches produced on the same production line were affected.

    Contains “sterili*”Read the Form 483 →

  3. AnazaoHealth CorporationInspection ended Jul 29, 2022 · FEI 3011152407 · Observation 4

    The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented. Specifically, on May 19, 2022, your contract testing laboratory detected visual turbidity in the sterility testing (b) (4) for your (b) (4) Nutrient Cocktail lot (b) (4), and confirmed that this turbidity was caused by microbial contamination with Staphylococcus epidermidis. However, your contract testing laboratory failed to …

    Contains “sterili*”Read the Form 483 →

  4. AnazaoHealth CorporationInspection ended Jul 29, 2022 · FEI 3011152407 · Observation 5

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, your firm stores equipment with difficult to clean surfaces inside the ISO 7 areas surrounding the ISO 5 aseptic processing areas, such as surfaces that are porous, particle-generating, or visibly dirty. Examples include the following: A) a clear plastic storage bin in the ISO 7 area of …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  5. Protherics UK Ltd.Inspection ended Jun 23, 2022 · FEI 3001417487 · Observation 2

    (b)(4) testing (b)(4) conducted in - Grade (b)(4) area in September 2021 as part of the facility qualification was deficient. Specifically, A. There was a lack of consistent supply of (b)(4) for an adequate assessment of (b)(4) HEPA (b)(4) or the absence of (b)(4) as required per (b)(4)-04.013, v1, section 6.2. B. Aseptic operations carried out during routine processing including worst-case activities which cause the most potential for product …

    Contains “aseptic*”Read the Form 483 →

  6. ID Biomedical Corporation of QuebecInspection ended May 20, 2022 · FEI 3004835647 · Observation 3

    Procedures designed to prevent microbial contamination of drug products purporting to be sterile are inadequate. Specifically, (b)(4) styles worn by aseptic operators. The following deficiencies were noted for the (b)(4) worn by the operators working in the aseptic (b)(4): i. [illegible] with the (b)(4) (b)(4) There are (b)(4) on the [illegible] has been specifically evaluated by sterility approximately (b)(4) assurance for the impact to the …

    Contains “purporting to be sterile”Read the Form 483 →

  7. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 1

    Personnel were observed conducting aseptic manipulations or placing equipment/supplies in an area that blocked the movement of first pass air around an open unit, whether before or after it is filled with sterile product Specifically, A. On 4/26/2022 aseptic processing visual observations were made of the sterile drug product, (b)(4) Sterile Solution for Injection, Lot # (b)(4) BUD 10/23/2023, your firm pharmacy technician while placing rubber …

    Contains “aseptic*”Read the Form 483 →

  8. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 2

    The (b)(4) intended to render final product sterile is not adequate to accomplish (b)(4) and/or is not pharmaceutical grade. Specifically, your firm fail to use sterile pharmaceutical grade (b)(4) during the processing of sterile drug products. For example, your firm uses a (b)(4), during the aseptic processing of the finished sterile drug product, Dexamethasone 24 mg/ml Sterile Solution pH 7. A review of your firm Production Log, I found 2 Lots …

    Contains “aseptic*”Read the Form 483 →

  9. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 3

    There is inadequate HEPA filter coverage or airflow over the area to which sterile product is exposed. Specifically, your firm has (b)(4) Systems in the cleanroom. (b)(4) does not appear to have enough HEPA filters in proper locations to provide adequate coverage to ensure ISO 5 environment is maintained from the ISO 5 BSC used for aseptic processing, to the (b)(4) and from the (b)(4) to the (b)(4) crimping station. This is a repeat observation.

    Contains “ISO 5”Read the Form 483 →

  10. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 4

    … Your firm following our discussion of observed deficiencies disposed of both aseptically processed lots.

    Contains “aseptic*”Read the Form 483 →

  11. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 5

    Sinks or drains are present in the cleanroom where the ISO 5 area is located. Specifically, your firm's (b)(4) system, located approximately (b)(4) feet apart within the ISO 7 Buffer Room/Cleanroom, require water to drained from the unit using a (b)(4) plastic bucket that was in your firm's ISO 8 Ante Room/Gowning at the completion of a cycle. Your firm's (b)(4) are located adjacent to ISO 5 BSC and the ISO 5 LAFU used for aseptic processing and …

    Contains “ISO 5”Read the Form 483 →

  12. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 6

    Unsealed, loose ceiling tiles were observed in your cleanroom. Specifically, I observed an exposed/unsealed fire sprinkler head within your firm's ISO 8 Ante Room/Gowning, and ISO 7 HD Anteroom/Prep Room, and ISO 7 Buffer Room/Cleanroom along with unsealed ceiling tiles.

    Contains “gown*”Read the Form 483 →

  13. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 7

    The ISO-classified have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, foreign particulates were observed on the top of the firm's ISO 5 BSC, ISO 5 LAFU and (b)(4) systems located in the ISO 7 Non-Hazardous Buffer Room.

    Contains “ISO 5”Read the Form 483 →

  14. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 8

    Cleanroom smoke studies conducted in cleanroom under dynamic conditions are inadequate. Specifically, your firm's smoke studies conducted as part of your firm August 18, 2021, Cleanroom re-certification is inadequate. For example, your firm's smoke studies failed to include and assess complex intervention(s) within your firm's ISO 5 BSC as part of the unit's recertification process.

    Contains “smoke stud*”Read the Form 483 →

  15. Revive Rx LLCInspection ended May 4, 2022 · FEI 3016710945 · Observation 9

    (b)(4) glassware used in the processing of sterile drug product is exposed to less than ISO 5 air quality. Specifically, your firm failed to ensure (b)(4) glassware used in aseptic processing is not exposed to less than ISO 5 air. For example, on 4/19/2022, your firm was observed using an uncovered glass beaker that had undergone (b)(4), used in the processing of the sterile drug product, (b)(4) vial for injection, Lot #(b)(4), BUD 7/31/22 within …

    Contains “ISO 5”Read the Form 483 →

  16. Serum Institute of India Pvt. Ltd.Inspection ended Apr 19, 2022 · FEI 3020223359 · Observation 10

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) You do not perform identification each time action level is reached for each (b)(4) 100 b) Your [illegible] did not consider manufacturing operations when determining sample locations. c) You do not perform complete investigations when an action level is reached to include root cause and corrective action. d) You do not have a …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  17. Family PharmacyInspection ended Mar 11, 2022 · FEI 3015859129 · Observation 1

    Your facility was operated in a way that permits poor flow of materials. Specifically, A. During the compounding of Hydromorphone 1 mg/mL infusion lot #528, the pharmacy technician failed to wipe down the (b) (4) and the supplies with sterile (b) (4) prior to introduction into ISO 5 BSC. B. Prior to and after compounding Hydromorphone 1 mg/mL infusion lot #528, the pharmacy technician failed to wipe down the sterile (b) (4) bottle prior to …

    Contains “ISO 5”Read the Form 483 →

  18. Family PharmacyInspection ended Mar 11, 2022 · FEI 3015859129 · Observation 2

    Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, the sporicidal agent, (b) (4), that your firm uses to clean the surfaces inside of the ISO 5 BSC requires a (b) (4) contact time. Your technician stated that this product is used on an (b) (4) (b) (4) basis and left on the inside surface of the ISO 5 BSC to dry while he …

    Contains “ISO 5”Read the Form 483 →

  19. Family PharmacyInspection ended Mar 11, 2022 · FEI 3015859129 · Observation 3

    Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worse case activities and conditions that provide a challenge to aseptic operations. Specifically, the firm's (b) (4) media fill which mimics their high-risk infusion compound, Hydromorphone, was performed with (b) (4) IV bags of (b) (4) each for a total batch size of (b) (4). However, the firm's highest volume as seen on their (b) …

    Contains “media fill*”Read the Form 483 →

  20. Family PharmacyInspection ended Mar 11, 2022 · FEI 3015859129 · Observation 5

    The cycle parameters used for (b) (4) of materials used to prepare sterile injectable drug products were not verified using endotoxin indicators. Specifically, you do not use endotoxin indicators to ensure and verify that the temperature and time cycle used to sterilize and (b) (4) glassware is adequate. (REPEAT OBSERVATION)

    Contains “sterili*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.