Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Pharmcore Inc. dba Hallandale PharmacyInspection ended Sep 24, 2021 · FEI 3014480778 · Observation 1
Cleaning procedures are inadequate to prevent cross contamination. Specifically, Your firm cleans and disinfects the sterile compounding suites for hazardous and non-hazardous drug products [illegible] basis prior to aseptic activities. Your current procedure is to clean the sterile hazardous suite first before cleaning the sterile non-hazardous suite. The order in which you clean is inappropriate because it may potentially cross contaminate and …
Contains “aseptic*”Read the Form 483 →
Pharmcore Inc. dba Hallandale PharmacyInspection ended Sep 24, 2021 · FEI 3014480778 · Observation 2
You did not take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, Your QA Director stated that a thorough '[(b)(4)]' clean is conducted when an objectionable microorganism is found during environmental monitoring of your ISO classified areas. However, your firm failed to thoroughly clean and disinfect the sterile hazardous and …
Contains “ISO 5”Read the Form 483 →
Pharmcore Inc. dba Hallandale PharmacyInspection ended Sep 24, 2021 · FEI 3014480778 · Observation 3
Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, On 9/15/2021, I observed your sterile technician fail to properly disinfect the plastic bag containing the sterile [(b)(4)] and sterile [(b)(4)] used to [(b)(4)] and collect the mixture of Gonadorelin, Lot #117356 prior to placement in the ISO5 Laminar Flow Hood which is located in your firm's ISO7 Mixing/Weighing room for sterile …
Contains “aseptic*”Read the Form 483 →
OSRX, Inc.Inspection ended Sep 23, 2021 · FEI 3014549846 · Observation 1
OBSERVATION 1 Your firm's current laminar air [illegible] (smoke studies) were not performed under [illegible] allowing aseptic operations that are representative [illegible] compounding practices nor did they simulate all critical unit operations and interventions used in compounding of your sterile drug products. Specifically, Smoke studies conducted by your firm, in May of 2021 simulate the normal operating [illegible] of the sterile ISO 5 …
Contains “laminar*”Read the Form 483 →
Montana Compounding Pharmacy P.C.Inspection ended Sep 22, 2021 · FEI 3011412185 · Observation 1
… b) Your firm does not replace gowns between producing a highly potent and/or hazardous drug product and continuing to compound other drug products. This is a repeat observation.
Contains “gown*”Read the Form 483 →
Revive Rx, LLC dba Revive Rx PharmacyInspection ended Aug 6, 2021 · FEI 3016710945 · Observation 1
The certification of the ISO 5 areas was inadequate. Specifically, smoke studies were not conducted to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions.
Contains “ISO 5”Read the Form 483 →
Revive Rx, LLC dba Revive Rx PharmacyInspection ended Aug 6, 2021 · FEI 3016710945 · Observation 2
The [(b) (4)] used for depyrogenation of product/equipment intended to be sterile were not lethal to heat-resistant microorganisms. Specifically, Your firm uses a [(b) (4)] to depyrogenate glassware used in the preparation of your firm's sterile injectable products. However, you do not use endotoxin indicators to ensure and verify that the [(b) (4)] and [(b) (4)] used to depyrogenate glassware is adequate.
Contains “depyrogen*”Read the Form 483 →
Revive Rx, LLC dba Revive Rx PharmacyInspection ended Aug 6, 2021 · FEI 3016710945 · Observation 3
Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your Media Fill Challenge log sheet documents that a total of [illegible] trials ([illegible] for control and [illegible] for evaluation) will be used to conduct media fills. Review of media fills conducted since 8/2020 revealed that the …
Contains “media fill*”Read the Form 483 →
Revive Rx, LLC dba Revive Rx PharmacyInspection ended Aug 6, 2021 · FEI 3016710945 · Observation 4
Product intended to be sterile was exposed to lower than ISO 5 classified quality air. Specifically, your firm's procedure for [(b) (4)] finished drug products includes [(b) (4)] vials under the ISO 5 laminar flow hood and then removing these vials outside the hood to transfer into the [(b) (4)].
Contains “ISO 5”Read the Form 483 →
People's Custom Rx and Clinical Care, LLCInspection ended Aug 5, 2021 · FEI 3003780900 · Observation 1
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, the firm compounds sterile drug products which involves several aseptic manipulation steps. The firm's sterile drug product batch size can range up to (b) (4) for the sterile drug product Cyclosporine 1%. The current media fills are …
Contains “media fill*”Read the Form 483 →
Med Shop Total Care Inc.Inspection ended Jul 27, 2021 · FEI 3002835459 · Observation 1
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, you had several environmental monitoring results in the ISO 5 environment where you did not identify the microorganism and continued to produce and distribute sterile drug products without a complete investigation and …
Contains “ISO 5”Read the Form 483 →
Med Shop Total Care Inc.Inspection ended Jul 27, 2021 · FEI 3002835459 · Observation 5
Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves. Specifically, on July 6, 2021, I observed personnel touch the keyboard or other surfaces multiple times located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or …
Contains “ISO 5”Read the Form 483 →
Med Shop Total Care Inc.Inspection ended Jul 27, 2021 · FEI 3002835459 · Observation 6
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, a) Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. You do not include the largest …
Contains “media fill*”Read the Form 483 →
Med Shop Total Care Inc.Inspection ended Jul 27, 2021 · FEI 3002835459 · Observation 7
Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, after notification from your contract laboratory of a sterility failure for bulk intermediate vial of Bupivacaine [illegible], lot (b)(4), you recalled drug products that contained this lot.
Contains “sterili*”Read the Form 483 →
ACRX Specialty Pharmacy lncInspection ended Jul 23, 2021 · FEI 3015134033 · Observation 1
The ISO 5 classified aseptic processing areas had difficult to clean and visibly dirty equipment or surface. Specifically, It was observed that the ISO 5 classified aseptic processing areas contained difficult to clean and visibly dirty surfaces and that Pharmacist-in-Charge (PIC) did not clean them before and after producing Glutathione (BUD MDV) 200 mg/ml Inject Soln, Lot #07122021@8 on 7/12/2021 for the following: A. The HEPA filter cover …
Contains “ISO 5”Read the Form 483 →
ACRX Specialty Pharmacy lncInspection ended Jul 23, 2021 · FEI 3015134033 · Observation 2
… Unknown rust-like stains were observed on a metal wheel of the ISO 5 LAFH located in the ISO 7 cleanroom. D. A small ball of cotton-like substance and unknown brownish dirt stuck to a cart used to store various materials for sterile compounding in the ISO 7 cleanroom.
Contains “ISO 5”Read the Form 483 →
ACRX Specialty Pharmacy lncInspection ended Jul 23, 2021 · FEI 3015134033 · Observation 4
Dynamic smoke studies are not representative of production. Specifically, It was observed that during aseptic processing, a sterile bag containing (B) hung on a hook inside the ISO 5 LAFH swung back and forth for over a minute immediately after PIC released the bag, which he held at approximately a 45-degree angle to draw (B) from a port of the bag, but the video of smoke study conducted 3/1/2021 showed a sterile bag hung on the hook was static.
Contains “smoke stud*”Read the Form 483 →
ACRX Specialty Pharmacy lncInspection ended Jul 23, 2021 · FEI 3015134033 · Observation 5
Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product. Specifically, It was observed that a sterile bag containing (B) hung on a hook inside the ISO 5 LAFH swung back and forth for over a minute every time after PIC used a sterile syringe to draw from a port of the bag to dissolve bulk drug …
Contains “aseptic*”Read the Form 483 →
ACRX Specialty Pharmacy lncInspection ended Jul 23, 2021 · FEI 3015134033 · Observation 6
Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, Each (B) ingredient in a non-sterile plastic weighing boat used to produce a sterile drug product was weighed inside the non-sterile (B) hood (BY). It was observed that PIC used a (B) sterile wipe to hold the bottom of the weighing boat and placed it on the working surface of the ISO 5 LAFH without wiping the entire weighing boat.
Contains “aseptic*”Read the Form 483 →
ACRX Specialty Pharmacy lncInspection ended Jul 23, 2021 · FEI 3015134033 · Observation 7
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, Prior to donning gowning apparel, PIC washed his hands and forearms in a sink in the ISO 7 anteroom and then walked to a cart in the room to get wipes to dry his hands and forearms; however, it was observed water was dripping onto the ground from his hands and forearms. The shoe cover that touched the wet spillage …
Contains “gown*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.