ACRX Specialty Pharmacy Inc
3200 Soaring Gulls Dr Ste 101, Las Vegas, Nevada, United States
FEI 3015134033
FDA has one inspection on file for ACRX Specialty Pharmacy Inc in Las Vegas, Nevada (FEI 3015134033). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2021
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Dirty equipment and surfaces in ISO 5
The ISO 5 classified aseptic processing areas had difficult to clean and visibly dirty equipment or surface. Specifically, It was observed that the ISO 5 classified aseptic processing areas contained difficult to clean and visibly dirty surfaces and that Pharmacist-in-Charge (PIC) did not clean them before and after producing Glutathione (BUD MDV) 200 mg/ml Inject Soln, Lot #07122021@8 on 7/12/2021 for the following: A. The HEPA filter cover positioned above the work surface inside the ISO 5 LAFH contained brownish stains on its surface. B. The frames of the HEPA filter and its joints with the ISO 5 LAFH contained brownish stains. C. There was a gap between a stainless-steel bar pot rack with hooks used to hold sterile bags or devices and the holder at its joint with the ISO 5 LAFH on both sides, which was difficult to clean. D. The red IV seals holder hung on a bar pot rack inside the ISO 5 LAFH. The IV seals must be removed in order to clean the holder thoroughly. E. Unknown stains were observed in a hard-to-reach area under a row of light bulbs of the LAFH and near the HEPA filter.
- Observation 2
Non-microbial contamination observed
Non-microbial contamination was observed in your production area. Specifically, A. A dusty filth-like material was present on the back side of a (B) hood (BYE) used to produce non-sterile products and to weigh ingredients used to produce sterile products. Also, unknown powders were present at the corner of the working surface after the hood had been cleaned for weighing ingredients used for producing Glutathione (BUD MDV) 200 mg/ml Inject Soln, Lot #07122021@8 on 7/12/2021. B. Unknown stains were widely distributed on the interior surface of the front window of a (B) hood (BY{4)) used to produce non-sterile products. C. Unknown rust-like stains were observed on a metal wheel of the ISO 5 LAFH located in the ISO 7 cleanroom. D. A small ball of cotton-like substance and unknown brownish dirt stuck to a cart used to store various materials for sterile compounding in the ISO 7 cleanroom.
Show observations 3 to 7
- Observation 3
Unverified raw material endotoxin risk
Your firm produced drug products with materials that had not been verified to assure that they did not contribute to endotoxin contamination that may be objectionable given the product's intended use. Specifically, You used Glutathione (B) dietary supplement to produce Glutathione (BUD MDV) 200 Mg/MI Inject Soln. For example, you purchased Glutathione (B) dietary supplement, lot # (B), from (B)(4)777 on 11/18/2020 and used this ingredient to produce Glutathione (BUD MDV) 200 Mg/MI Inject Soln, Lot # 05102021@12 on 5/10/2021. During the period of April to June 2021, you produced Glutathione (BUD MDV) 200 Mg/MI Inject Soln for 9 prescription orders: Rx (b)(6), Rx (b)(6), Rx (b)(6), Rx (b)(6), Rx (b)(6), Rx (B)(6), Rx (B)(6), Rx (B)(6) and Rx (B)(6); however, you have not verified that Glutathione (B) dietary supplement did not contribute to endotoxin contamination for every batch you produced and within its Beyond Use Date, which is 183 days after the compounding date.
- Observation 4
Smoke studies not representative
Dynamic smoke studies are not representative of production. Specifically, It was observed that during aseptic processing, a sterile bag containing (B) hung on a hook inside the ISO 5 LAFH swung back and forth for over a minute immediately after PIC released the bag, which he held at approximately a 45-degree angle to draw (B) from a port of the bag, but the video of smoke study conducted 3/1/2021 showed a sterile bag hung on the hook was static.
- Observation 5
First-pass air blocked by supplies
Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product. Specifically, It was observed that a sterile bag containing (B) hung on a hook inside the ISO 5 LAFH swung back and forth for over a minute every time after PIC used a sterile syringe to draw from a port of the bag to dissolve bulk drug substances or other ingredients during aseptic processing of Glutathione (BUD MDV) 200 mg/ml Inject Soln, Lot #07122021@8 on 7/12/2021. Your sterile vial sealed with stopper, opened sterile wipes, and syringes with exposed needles were placed under or near the bag. Also, [illegible] into a sterile vial approximately a foot apart from the bag inside the ISO 5 LAFH.
- Observation 6
Supplies not disinfected before entry
Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, Each (B) ingredient in a non-sterile plastic weighing boat used to produce a sterile drug product was weighed inside the non-sterile (B) hood (BY). It was observed that PIC used a (B) sterile wipe to hold the bottom of the weighing boat and placed it on the working surface of the ISO 5 LAFH without wiping the entire weighing boat.
- Observation 7
Improper gowning leading to contamination
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, Prior to donning gowning apparel, PIC washed his hands and forearms in a sink in the ISO 7 anteroom and then walked to a cart in the room to get wipes to dry his hands and forearms; however, it was observed water was dripping onto the ground from his hands and forearms. The shoe cover that touched the wet spillage had direct contact with the sterile gowning apparel while donning it or it can be brought into the ISO 7 cleanroom.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015134033 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015134033. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.