ACRX Specialty Pharmacy lnc Form 483, July 2021
FDA issued this Form 483 to ACRX Specialty Pharmacy lnc in Las Vegas, Nevada (FEI 3015134033) at the end of a drug inspection that ended July 23, 2021. It lists 7 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 28, 2021. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 23, 2021
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Oct 28, 2021
- 97 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Dirty equipment and surfaces in ISO 5
The ISO 5 classified aseptic processing areas had difficult to clean and visibly dirty equipment or surface. Specifically, It was observed that the ISO 5 classified aseptic processing areas contained difficult to clean and visibly dirty surfaces and that Pharmacist-in-Charge (PIC) did not clean them before and after producing Glutathione (BUD MDV) 200 mg/ml Inject Soln, Lot #07122021@8 on 7/12/2021 for the following: A. The HEPA filter cover positioned above the work surface inside the ISO 5 LAFH contained brownish stains on its surface. B. The frames of the HEPA filter and its joints with the ISO 5 LAFH contained brownish stains. C. There was a gap between a stainless-steel bar pot rack with hooks used to hold sterile bags or devices and the holder at its joint with the ISO 5 LAFH on both sides, which was difficult to clean. D. The red IV seals holder hung on a bar pot rack inside the ISO 5 LAFH. The IV seals must be removed in order to clean the holder thoroughly. E. Unknown stains were observed in a hard-to-reach area under a row of light bulbs of the LAFH and near the HEPA filter.
- 2
Non-microbial contamination observed
Non-microbial contamination was observed in your production area. Specifically, A. A dusty filth-like material was present on the back side of a (B) hood (BYE) used to produce non-sterile products and to weigh ingredients used to produce sterile products. Also, unknown powders were present at the corner of the working surface after the hood had been cleaned for weighing ingredients used for producing Glutathione (BUD MDV) 200 mg/ml Inject Soln, Lot #07122021@8 on 7/12/2021. B. Unknown stains were widely distributed on the interior surface of the front window of a (B) hood (BY{4)) used to produce non-sterile products. C. Unknown rust-like stains were observed on a metal wheel of the ISO 5 LAFH located in the ISO 7 cleanroom. D. A small ball of cotton-like substance and unknown brownish dirt stuck to a cart used to store various materials for sterile compounding in the ISO 7 cleanroom.
- 3
Unverified raw material endotoxin risk
Your firm produced drug products with materials that had not been verified to assure that they did not contribute to endotoxin contamination that may be objectionable given the product's intended use. Specifically, You used Glutathione (B) dietary supplement to produce Glutathione (BUD MDV) 200 Mg/MI Inject Soln. For example, you purchased Glutathione (B) dietary supplement, lot # (B), from (B)(4)777 on 11/18/2020 and used this ingredient to produce Glutathione (BUD MDV) 200 Mg/MI Inject Soln, Lot # 05102021@12 on 5/10/2021. During the period of April to June 2021, you produced Glutathione (BUD MDV) 200 Mg/MI Inject Soln for 9 prescription orders: Rx (b)(6), Rx (b)(6), Rx (b)(6), Rx (b)(6), Rx (b)(6), Rx (B)(6), Rx (B)(6), Rx (B)(6) and Rx (B)(6); however, you have not verified that Glutathione (B) dietary supplement did not contribute to endotoxin contamination for every batch you produced and within its Beyond Use Date, which is 183 days after the compounding date.
- 4
Smoke studies not representative
Dynamic smoke studies are not representative of production. Specifically, It was observed that during aseptic processing, a sterile bag containing (B) hung on a hook inside the ISO 5 LAFH swung back and forth for over a minute immediately after PIC released the bag, which he held at approximately a 45-degree angle to draw (B) from a port of the bag, but the video of smoke study conducted 3/1/2021 showed a sterile bag hung on the hook was static.
- 5
First-pass air blocked by supplies
Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product. Specifically, It was observed that a sterile bag containing (B) hung on a hook inside the ISO 5 LAFH swung back and forth for over a minute every time after PIC used a sterile syringe to draw from a port of the bag to dissolve bulk drug substances or other ingredients during aseptic processing of Glutathione (BUD MDV) 200 mg/ml Inject Soln, Lot #07122021@8 on 7/12/2021. Your sterile vial sealed with stopper, opened sterile wipes, and syringes with exposed needles were placed under or near the bag. Also, [illegible] into a sterile vial approximately a foot apart from the bag inside the ISO 5 LAFH.
- 6
Supplies not disinfected before entry
Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, Each (B) ingredient in a non-sterile plastic weighing boat used to produce a sterile drug product was weighed inside the non-sterile (B) hood (BY). It was observed that PIC used a (B) sterile wipe to hold the bottom of the weighing boat and placed it on the working surface of the ISO 5 LAFH without wiping the entire weighing boat.
- 7
Improper gowning leading to contamination
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated. Specifically, Prior to donning gowning apparel, PIC washed his hands and forearms in a sink in the ISO 7 anteroom and then walked to a cart in the room to get wipes to dry his hands and forearms; however, it was observed water was dripping onto the ground from his hands and forearms. The shoe cover that touched the wet spillage had direct contact with the sterile gowning apparel while donning it or it can be brought into the ISO 7 cleanroom.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3015134033, newest first.
- Form 483, March 2019FDA record date Mar 20, 2019 · Posted Apr 30, 2019
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.