Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Vital Care of Dickson, LLC.Inspection ended Mar 11, 2020 · FEI 3015826069 · Observation 3
Pressure differentials are not monitored in areas where aseptic processing occurs. Specifically, A) Pressure differentials between areas with different air classifications (ISO 6 cleanroom and ISO 7 anteroom) are not routinely monitored/documented prior or during sterile drug production. A review of the firm's compounding records noted that the firm does not routinely document pressure differentials. B) Pressure differentials are measured with …
Contains “aseptic*”Read the Form 483 →
Vital Care of Dickson, LLC.Inspection ended Mar 11, 2020 · FEI 3015826069 · Observation 5
Disinfecting agents used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, the disinfectant C(b)(4) used by the firm is non-sterile.
Contains “ISO 5”Read the Form 483 →
Piedmont Hospital, Inc.Inspection ended Feb 18, 2020 · FEI 1075523 · Observation 1
Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, your (b) (4) and (b) (4) used (b) (4) for the disinfection/cleaning of your sterile compounding hood is not sterile. The hood is used for compounding sterile drug products.
Contains “ISO 5”Read the Form 483 →
Blount Discount Pharmacy, Inc.Inspection ended Feb 13, 2020 · FEI 3015826061 · Observation 2
Agents used for cleaning the laminar flow hood and other equipment between products do not include a deactivating agent (e.g. oxidizing agent) to prevent cross-contamination. Specifically, the cleaning agents I observed used between batches for equipment and the hood were [(b)(4)] and dish soap only.
Contains “laminar*”Read the Form 483 →
Surgery Pharmacy Services, Inc.Inspection ended Dec 6, 2019 · FEI 3010704905 · Observation 2
Personnel failed to disinfect or change gloves frequently enough. Specifically, the technician was observed during preparation of TPN products on 11/18/2019. For example, she moved her hands out of the ISO5 hood and then back into the hood without sanitizing, tying out the trash bag in the large trash bin located in the ISO8 anteroom, and resuming aseptic production activities in the ISO5 hood with hands with [illegible]. She did not change her …
Contains “aseptic*”Read the Form 483 →
Surgery Pharmacy Services, Inc.Inspection ended Dec 6, 2019 · FEI 3010704905 · Observation 3
Personnel engaged in aseptic processing were observed with exposed skin in critical areas. On 11/18/2019 and 11/19/2019, the technician was observed leaning significantly into the ISO5 certified hood with her forehead exposed while leaning during aseptic production activities.
Contains “aseptic*”Read the Form 483 →
Surgery Pharmacy Services, Inc.Inspection ended Dec 6, 2019 · FEI 3010704905 · Observation 4
Equipment, materials, and/or supplies are not adequately disinfected prior to entering aseptic processing areas. Specifically, materials are not adequately disinfected to stricter classifications. Large drug components, such as [illegible], are loaded and then moved into temporary storage baskets within the pharmacy area prior to being placed into the ISO5 hood. For production, materials are placed on ISO5 worksurfaces prior to disinfection.
Contains “aseptic*”Read the Form 483 →
Surgery Pharmacy Services, Inc.Inspection ended Dec 6, 2019 · FEI 3010704905 · Observation 5
Media fills were not performed that closely simulate appropriate, worst-case activities and conditions. Specifically, the media fills consist of preparing and [illegible] vials intended to represent finished product, though activities such as the manual production and [illegible] for intracameral injections are not represented.
Contains “media fill*”Read the Form 483 →
Surgery Pharmacy Services, Inc.Inspection ended Dec 6, 2019 · FEI 3010704905 · Observation 6
Disinfecting agents used in the ISO5 area are [illegible]; [illegible] is non-sterile and is routinely used in supporting aseptic processing areas.
Contains “aseptic*”Read the Form 483 →
Surgery Pharmacy Services, Inc.Inspection ended Dec 6, 2019 · FEI 3010704905 · Observation 10
ISO-5 classified areas were not certified or verified under operational conditions representative of dynamic conditions. The smoke studies performed only include evaluation of the hood when not fully loaded and do not include evaluation of a fully-loaded hood, such as when equipment takes up a significant amount of space and potentially interrupts the unidirectional airflow hood design.
Contains “ISO 5”Read the Form 483 →
Nanobots Healthcare, LLC dba Assurance InfusionInspection ended Dec 3, 2019 · FEI 3015617746 · Observation 2
On 11/19/2019, I noted turbidity and/or precipitate in the following sterility samples: A. Tri-Mix lot #11112019@9 B. Tri-Mix, lot #11112019@10 C. Tri-Mix, lot #11112019@21 To date, your firm has not performed an investigation.
Contains “sterili*”Read the Form 483 →
Nanobots Healthcare, LLC dba Assurance InfusionInspection ended Dec 3, 2019 · FEI 3015617746 · Observation 3
On 11/15/19, during the aseptic processing of Morphine 5mg/ml for Injection, lot #11132019@16, an operator was observed placing his gloved hands outside the ISO 5 area to retrieve supplies. Upon re-entry into the ISO 5 hood with the supplies, he failed to re-sanitize his hands. The same operator was observed with the skin of his forehead partially exposed. The operator was observed introducing the exposed skin of his forehead inside the ISO 5 …
Contains “aseptic*”Read the Form 483 →
Nanobots Healthcare, LLC dba Assurance InfusionInspection ended Dec 3, 2019 · FEI 3015617746 · Observation 4
The ISO 5 classified area was not certified under dynamic conditions. Specifically, smoke studies were not conducted to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions during the last certification.
Contains “ISO 5”Read the Form 483 →
Nanobots Healthcare, LLC dba Assurance InfusionInspection ended Dec 3, 2019 · FEI 3015617746 · Observation 5
Your firm does not have sterility testing data to support an assigned BUD of up to 90 days for intrathecal stock solutions. For example, the stock solution for Hydromorphone HCl is assigned a BUD of 90 days after production.
Contains “sterili*”Read the Form 483 →
Nanobots Healthcare, LLC dba Assurance InfusionInspection ended Dec 3, 2019 · FEI 3015617746 · Observation 7
Your firm uses an [illegible] for the depyrogenation of glassware used in the production of sterile, injectable drug products. The [illegible] used for depyrogenation has never been verified. In addition, a biological indicator has never been used to verify the adequacy of the depyrogenation process.
Contains “depyrogen*”Read the Form 483 →
Nanobots Healthcare, LLC dba Assurance InfusionInspection ended Dec 3, 2019 · FEI 3015617746 · Observation 8
Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your log sheet for conducting a high risk media fill challenge documents that a total of [illegible] vials (for control and [illegible] for evaluation) will be used to conduct media fills. Review of media fills conducted since 7/18 …
Contains “media fill*”Read the Form 483 →
Nanobots Healthcare, LLC dba Assurance InfusionInspection ended Dec 3, 2019 · FEI 3015617746 · Observation 9
The wipers placed on the work surface inside the ISO 5 hood during production are not sterile. The wipers are used for the placement of [illegible] used in production.
Contains “ISO 5”Read the Form 483 →
New Era Pharmacy, LLCInspection ended Nov 27, 2019 · FEI 3003429652 · Observation 1
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, on 11/22/19, an employee was observed wearing a non-sterile face mask and a non-sterile knee-length gown. The non-sterile sleeves of his gown were inside the ISO 5 Biological Safety Cabinet during sterile production of HCG Microdose 1000 IU/10 mL (50 IU/0.5 mL) Injectable, Lot HM-1122S19, expiration date 12/6/19.
Contains “gown*”Read the Form 483 →
New Era Pharmacy, LLCInspection ended Nov 27, 2019 · FEI 3003429652 · Observation 2
ISO-5 classified areas were not certified under dynamic conditions. Specifically, the dynamic smoke studies conducted on 10/16/19 and 4/3/19 in the ISO 5 Bio-Safety Cabinet used to produce hazardous drugs and ISO 5 Laminar Flow Hood used to produce non-hazardous drugs are inadequate in that there are no videos or adequate written description available to verify the operator movement, interventions, equipment, etc.
Contains “ISO 5”Read the Form 483 →
New Era Pharmacy, LLCInspection ended Nov 27, 2019 · FEI 3003429652 · Observation 3
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills are not performed in a manner that simulates challenging production practices such as maximum number of people in the room, the duration of aseptic production and representative container type and size used during routine …
Contains “media fill*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.