Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Rapid Equine Solutions, LLCInspection ended Aug 9, 2019 · FEI 3006708880 · Observation 3
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to product aseptic conditions. You have not established if the current cleaning method is capable of removing residuals of API, cleaning and sanitizing agents and objectionable organisms from multi-use equipment and utensils used to produce sterile products.
Contains “aseptic*”Read the Form 483 →
Rapid Equine Solutions, LLCInspection ended Aug 9, 2019 · FEI 3006708880 · Observation 4
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, a) Aseptic manipulations occur in the (b) (4) hood, model (b) (4) serial (b) (4) that is not ISO5 classified. In addition, the blending of ingredients for Aspirin 40% (Sodium Salicylate 400mg/mL) Batch # 20190724-2 and Folic Acid 50mg/mL Batch #20190724-3 was observed to occur on a …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →
Rapid Equine Solutions, LLCInspection ended Aug 9, 2019 · FEI 3006708880 · Observation 5
Clothing of personnel engaged in the production of drug products is not appropriate for the duties they perform. Specifically, non-sterile gowning articles are worn by the operators during the cleaning of surfaces and during the production of drug products in the sterile cleanroom. Gowning articles consist of a non-sterile half surgical mask (ear loop style), non-sterile face mask which covers the head and neck, a non-sterile non-shedding knee …
Contains “gown*”Read the Form 483 →
Rapid Equine Solutions, LLCInspection ended Aug 9, 2019 · FEI 3006708880 · Observation 7
There are no data to assure that procedures designed to prevent microbiological contamination of drug products purporting to be sterile perform as intended. Specifically, the firm has not demonstrated that the terminal sterilization processes, including the (b) (4) process and the (b) (4) process for injectable drugs, produce drug products with an acceptable sterility assurance level. For example, the firm produced injectable drugs such as …
Contains “purporting to be sterile”Read the Form 483 →
Southern California Compounding Pharmacy, LLCInspection ended Aug 1, 2019 · FEI 3010006900 · Observation 1
Personnel and environmental monitoring conducted within the ISO 5 Environments on a[(o)14) l frequency are deficient. Specifically, your firm does not perform growth promotion for each batch of media purchased or use a positive control when conducting'.(15) (4) gloved finger assessment and surface sampling. Your firm conducts gloved fingertip test and surface sampling as part of the compounding personnel qualification.
Contains “ISO 5”Read the Form 483 →
Southern California Compounding Pharmacy, LLCInspection ended Aug 1, 2019 · FEI 3010006900 · Observation 2
Gowning and aseptic practices are deficient. Specifically, during the aseptic operation for Rx# [illegible] on 7/10/19, we observed operator's head enter the ISO 5 Laminar Airflow Workstation (LAFW) during aseptic operations with exposed skin on forehead and cheeks. In addition, operator's skin was exposed at the ankle during aseptic operations and lower back skin was exposed during [(o) (4)] cleaning of the ISO 7 Buffer room.
Contains “gown*”Read the Form 483 →
Southern California Compounding Pharmacy, LLCInspection ended Aug 1, 2019 · FEI 3010006900 · Observation 3
The firm's cleaning and disinfecting procedure in the aseptic processing area are deficient. Add Continuation Page Specifically, Your firm uses non-sterile wipes sprayed with (5) (4) to wipe components prior to introduction into the ISO 5 Laminar Airflow Workstation (LAFW) and to clean ISO 5 LAFW counter top where the sterile drug products are prepared. On 7/10/19, during sterile compounding of Rx# [illegible], operator was observed moving items …
Contains “aseptic*”Read the Form 483 →
Southern California Compounding Pharmacy, LLCInspection ended Aug 1, 2019 · FEI 3010006900 · Observation 4
Smoke study conducted on 6/21/2019 to determine unidirectional airflows in ISO 5 LAFW was inadequate. Specifically, the smoke study failed to adequately simulate dynamic conditions and did not provide adequate coverage to demonstrate unidirectional airflow during routine operations. ISO 5 LAFW is where the firm produces all its sterile drug products.
Contains “smoke stud*”Read the Form 483 →
Mandell's Clinical PharmacyInspection ended Jul 25, 2019 · FEI 3010924627 · Observation 1
The ISO 5 classified area is located within a non-classified room (segregated production area). Specifically, The ISO-5 classified laminar flow (b) (4) (LF (b) (4) (Model (b) (4), for aseptic filling of sterile fertility drug products is located within a non-classified room which is not HEPA filter equipped to prevent risk of contamination. On 06/18/19, we observed water dripping from an 8 feet high ceiling vent that is approximately 15 feet away …
Contains “ISO 5”Read the Form 483 →
Mandell's Clinical PharmacyInspection ended Jul 25, 2019 · FEI 3010924627 · Observation 2
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, A. No media fill was performed for the ISO-5 classified LF (b) (4) (model (b) (4) located in the unclassified room. B. The firm performs media fill (b) (4) to support aseptic filling practices in the ISO-5 biological safety cabinet (BSC) …
Contains “media fill*”Read the Form 483 →
Mandell's Clinical PharmacyInspection ended Jul 25, 2019 · FEI 3010924627 · Observation 3
Non-depyrogenated equipment was used in sterile drug production. Specifically, The firm does not depyrogenate the (b) (4) that comes into direct contact during mixing of drug components in the ISO-7 production room. On 07/16/19, the pharmacist was observed using a (b) (4) the production of the Progesterone 50mg/ml in oil injection per the formula (b) (4)
Contains “depyrogen*”Read the Form 483 →
Mandell's Clinical PharmacyInspection ended Jul 25, 2019 · FEI 3010924627 · Observation 4
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, A. The ready to use sterile sporicidal ((b) (4) is not used to clean the ISO-5 BSC (located within the ISO-7 production room) and ISO-5 LF (b) (4) (located in an unclassified room). B. The ready to use sterile sporicidal ((b) (4) is used (b) (4) to clean the ISO-7 rooms …
Contains “ISO 5”Read the Form 483 →
Mandell's Clinical PharmacyInspection ended Jul 25, 2019 · FEI 3010924627 · Observation 5
… Prior to the next use, the glass items are rinsed with sterile water and then depyrogenated. B. The firm uses household antibacterial cleaner (b) (4) and sterile (b) (4) to clean the (b) (4) hood (b) (4) each (b) (4) is weighed and put into solutions.
Contains “depyrogen*”Read the Form 483 →
People’s Custom Rx and Clinical Care, LLCInspection ended Jul 24, 2019 · FEI 3003780900 · Observation 1
Personnel did not disinfect gloves to prevent contamination. Specifically, on 7/16/2019, during the aseptic processing of Tri-Mix, lot #07162019@34, an operator was observed placing her gloved hands outside the ISO 5 area and not consistently re-sanitizing prior to placing her gloved hands under the ISO 5 hood. THIS IS A REPEAT OBSERVATION
Contains “aseptic*”Read the Form 483 →
People’s Custom Rx and Clinical Care, LLCInspection ended Jul 24, 2019 · FEI 3003780900 · Observation 2
The cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, on 7/16/2019, an operator was observed using a non-sterile wipe to apply sterile, (b)(4) to the exterior of the HEPA filter inside the ISO 5 hood in the cleanroom.
Contains “ISO 5”Read the Form 483 →
People’s Custom Rx and Clinical Care, LLCInspection ended Jul 24, 2019 · FEI 3003780900 · Observation 3
Review of the certification report for the cleanrooms dated 3/28/19 revealed that smoke studies in the ISO 5 hood were not performed under dynamic conditions.
Contains “smoke stud*”Read the Form 483 →
Hieber’s PharmacyInspection ended Jul 17, 2019 · FEI 1000121499 · Observation 1
Procedures designed to identify and prevent insanitary conditions are not established and followed by your firm. Specifically, Your firm did not perform appropriate environmental monitoring in your aseptic processing areas. For example, pressure differentials between areas with different air classifications were not monitored before or during sterile drug production. The air pressure differential between the ISO 5 (b) (4) and the ISO 7 clean room …
Contains “aseptic*”Read the Form 483 →
Sun Pharmaceutical Industries Ltd.Inspection ended Jun 11, 2019 · FEI 3002809586 · Observation 1
OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. The Aseptic Process Validation Master Plan was not followed during execution of media fill run [illegible]. Specifically, [illegible] media fill failure on the [illegible] resulted in media fill failure with over [illegible] media batch contamination in the filled, incubated units. An investigation into the media …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Baxalta Belgium Manufacturing S.A.Inspection ended May 31, 2019 · FEI 3002806503 · Observation 1
… system and the SOP LE12QC2102/SOP-048719 for the microbial testing of the (b) (4) used for grade (b) (4) interventions and setup of the (b) (4) line by the aseptic (b) (4) operator. The introduction of the (b) (4) (b) (4) and (b) (4) testing positions, which corresponds to the (b) (4) and the (b) (4) respectively) took place in 2009. A retrospective review found that two results were not identified as being Out of Limit during the (b) (4) of …
Contains “aseptic*”Read the Form 483 →
Baxalta Belgium Manufacturing S.A.Inspection ended May 31, 2019 · FEI 3002806503 · Observation 5
… Quality Investigations, 23Mar2018, included a review of the following: batch records, events during production, product release testing results (including sterility), environmental and bioburden testing results, pre and post filter integrity results, visual inspection of retention samples (where applicable), stability review, and NAT/PCR and/or serology testing.
Contains “sterili*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.