Mandell's Clinical Pharmacy Form 483, July 2019
FDA issued this Form 483 to Mandell's Clinical Pharmacy in Somerset, New Jersey (FEI 3010924627) at the end of a drug inspection that ended July 25, 2019. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 31, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 25, 2019
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jan 31, 2020
- 190 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
ISO 5 area in non-classified room
The ISO 5 classified area is located within a non-classified room (segregated production area). Specifically, The ISO-5 classified laminar flow (b) (4) (LF (b) (4) (Model (b) (4), for aseptic filling of sterile fertility drug products is located within a non-classified room which is not HEPA filter equipped to prevent risk of contamination. On 06/18/19, we observed water dripping from an 8 feet high ceiling vent that is approximately 15 feet away from the ISO-5 classified LF (b) (4) in the non-classified room. There is no assurance that the lower quality air from unclassified room does not contaminate the environment when the (b) (4) is opened (b) (4) for cleaning, disinfection and to replace the (b) (4)
- 2
Inadequate media fills for aseptic operations
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, A. No media fill was performed for the ISO-5 classified LF (b) (4) (model (b) (4) located in the unclassified room. B. The firm performs media fill (b) (4) to support aseptic filling practices in the ISO-5 biological safety cabinet (BSC) (Model (b) (4)) located in the ISO-7 production room. The media fills are performed using a total of (b) (4) ((b) (4) to be tested). This does not represent the most challenging condition, in that the firm produces batches which range in size from (b) (4) vials.
- 3
Non-depyrogenated equipment used for sterile drugs
Non-depyrogenated equipment was used in sterile drug production. Specifically, The firm does not depyrogenate the (b) (4) that comes into direct contact during mixing of drug components in the ISO-7 production room. On 07/16/19, the pharmacist was observed using a (b) (4) the production of the Progesterone 50mg/ml in oil injection per the formula (b) (4)
- 4
Insufficient disinfectant contact time and coverage
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, A. The ready to use sterile sporicidal ((b) (4) is not used to clean the ISO-5 BSC (located within the ISO-7 production room) and ISO-5 LF (b) (4) (located in an unclassified room). B. The ready to use sterile sporicidal ((b) (4) is used (b) (4) to clean the ISO-7 rooms (production and ante). The manufacturer's label states that (b) (4) of contact time is effective for microbial control. However, the firm does not have a specific length of time for which personnel are required to leave the sporicidal on contact surfaces within the rooms.
- 5
Inadequate cleaning for highly potent drugs
You produced highly potent drugs without providing adequate cleaning of work surface and cleaning of utensils to prevent cross-contamination. Specifically, The firm does not use deactivating and decontaminating agent to eliminate the cross contamination of glass item and (b) (4) hood that is used for multiple drug products. A. The firm's glass items (beakers, graduate cylinders, stirring rods, vials etc.) that are used throughout the compounding process for multiple drug products are cleaned using antibacterial hand-wash soap and tap water. Prior to the next use, the glass items are rinsed with sterile water and then depyrogenated. B. The firm uses household antibacterial cleaner (b) (4) and sterile (b) (4) to clean the (b) (4) hood (b) (4) each (b) (4) is weighed and put into solutions.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJun 10, 2020CDER · 321 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010924627, newest first.
- Form 483, June 2022FDA record date Jun 17, 2022 · Posted Nov 7, 2022
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.