Mandell's Clinical Pharmacy
7 Cedar Grove Ln, Somerset, New Jersey, United States
FEI 3010924627
FDA has one inspection on file for Mandell's Clinical Pharmacy in Somerset, New Jersey (FEI 3010924627). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER). FDA has also posted a Form 483 dated Jun 17, 2022 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
ISO 5 area in non-classified room
The ISO 5 classified area is located within a non-classified room (segregated production area). Specifically, The ISO-5 classified laminar flow (b) (4) (LF (b) (4) (Model (b) (4), for aseptic filling of sterile fertility drug products is located within a non-classified room which is not HEPA filter equipped to prevent risk of contamination. On 06/18/19, we observed water dripping from an 8 feet high ceiling vent that is approximately 15 feet away from the ISO-5 classified LF (b) (4) in the non-classified room. There is no assurance that the lower quality air from unclassified room does not contaminate the environment when the (b) (4) is opened (b) (4) for cleaning, disinfection and to replace the (b) (4)
- Observation 2
Inadequate media fills for aseptic operations
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, A. No media fill was performed for the ISO-5 classified LF (b) (4) (model (b) (4) located in the unclassified room. B. The firm performs media fill (b) (4) to support aseptic filling practices in the ISO-5 biological safety cabinet (BSC) (Model (b) (4)) located in the ISO-7 production room. The media fills are performed using a total of (b) (4) ((b) (4) to be tested). This does not represent the most challenging condition, in that the firm produces batches which range in size from (b) (4) vials.
Show observations 3 to 5
- Observation 3
Non-depyrogenated equipment used for sterile drugs
Non-depyrogenated equipment was used in sterile drug production. Specifically, The firm does not depyrogenate the (b) (4) that comes into direct contact during mixing of drug components in the ISO-7 production room. On 07/16/19, the pharmacist was observed using a (b) (4) the production of the Progesterone 50mg/ml in oil injection per the formula (b) (4)
- Observation 4
Insufficient disinfectant contact time and coverage
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, A. The ready to use sterile sporicidal ((b) (4) is not used to clean the ISO-5 BSC (located within the ISO-7 production room) and ISO-5 LF (b) (4) (located in an unclassified room). B. The ready to use sterile sporicidal ((b) (4) is used (b) (4) to clean the ISO-7 rooms (production and ante). The manufacturer's label states that (b) (4) of contact time is effective for microbial control. However, the firm does not have a specific length of time for which personnel are required to leave the sporicidal on contact surfaces within the rooms.
- Observation 5
Inadequate cleaning for highly potent drugs
You produced highly potent drugs without providing adequate cleaning of work surface and cleaning of utensils to prevent cross-contamination. Specifically, The firm does not use deactivating and decontaminating agent to eliminate the cross contamination of glass item and (b) (4) hood that is used for multiple drug products. A. The firm's glass items (beakers, graduate cylinders, stirring rods, vials etc.) that are used throughout the compounding process for multiple drug products are cleaned using antibacterial hand-wash soap and tap water. Prior to the next use, the glass items are rinsed with sterile water and then depyrogenated. B. The firm uses household antibacterial cleaner (b) (4) and sterile (b) (4) to clean the (b) (4) hood (b) (4) each (b) (4) is weighed and put into solutions.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010924627 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010924627. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.