Skip to content

Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. ""ImprimisRx PharmacyInspection ended Apr 9, 2019 · FEI 3003348498 · Observation 1

    The ISO 7 Filling Room is not adequately constructed to ensure aseptic processing conditions. Specifically, during the cleaning of the ISO 7 Filling Room, we observed that the ceiling tiles were moving up and down when the technicians were wiping them with a mop. Within the ISO 7 Filling Room, the ISO 5 Laminar Air Flow Hood is used for the filling of sterile ophthalmic and injectable drug products.

    Contains “aseptic*”Read the Form 483 →

  2. Metro Drugs 3rd Avenue CorpInspection ended Apr 5, 2019 · FEI 3011795133 · Observation 1

    Disinfecting agents and cleaning pads or wipes used in the ISO 5 area aseptic processing areas are not sterile. Specifically, on 3/14/19, I observed an aseptic operator using non-sterile (b) (4) Wipes (b) (4), to disinfect the ISO 5 (b) (4) laminar flow hood and as a place mat where syringes, needles, and sterile (b) (4) were placed upon during aseptic filling.

    Contains “ISO 5”Read the Form 483 →

  3. Metro Drugs 3rd Avenue CorpInspection ended Apr 5, 2019 · FEI 3011795133 · Observation 3

    Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, a) Your firm did not evaluate any conditions that provide a challenge to aseptic operations as part of the firm's media fill. For example, operators do leave and reenter the ISO 5 area during production; however, this was not addressed …

    Contains “media fill*”Read the Form 483 →

  4. Metro Drugs 3rd Avenue CorpInspection ended Apr 5, 2019 · FEI 3011795133 · Observation 4

    ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow was not verified under dynamic conditions. The most recent smoke pattern tests were performed on (b) (4) by (b) (4) on the firm's ISO 5 biological safety cabinet and ISO 5 laminar flow clean bench under static conditions.

    Contains “ISO 5”Read the Form 483 →

  5. Triangle Compounding Pharmacy IncInspection ended Apr 4, 2019 · FEI 3004969894 · Observation 1

    … Particles were observed in vials of finished drug units, as well as during aseptic process simulations (4 out of 4 aseptic process simulations reviewed contained vials with particulate matter, ranging from approximately 2 to 9.8% of the total simulation vials). Finished drug units identified as containing particulate matter during your firm's visual inspection were destroyed, and the balance was dispensed. However, given the known presence of …

    Contains “aseptic*”Read the Form 483 →

  6. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 1

    Personnel engaged in aseptic processing were observed with exposed skin. Specifically, on 3/6/2019, your pharmacist was observed with exposed skin while compounding the sterile produced drug, P-105 Lot# 030719@1 BUD 09/07/19, Qty. [illegible] vials. Your pharmacist's sterile gloves failed to extend over the sleeves of the gown worn.

    Contains “aseptic*”Read the Form 483 →

  7. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 2

    Media fills were not performed that closely simulate, as appropriate, worst-case activities and conditions that prove a challenge to aseptic operations. Specifically, your media fill program fails to simulate activities and conditions within your firm's aseptic processing operations. For example, your firm's media fill aseptically simulates manipulating [illegible] compound batch size is [illegible] vials for the compounded [illegible].

    Contains “media fill*”Read the Form 483 →

  8. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 3

    Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing. Specifically, on 3/7/2019 during the aseptic processing of P-105 Lot# 030719@1 BUD 09/07/19, Qty. [illegible] vials, personnel performed a task in the ISO 7 cleanroom/processing area multiple times without re-sanitizing gloves. The skin of the pharmacist's hands was completely …

    Contains “ISO 5”Read the Form 483 →

  9. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 4

    Equipment and materials or supplies were not disinfected prior to entering the aseptic process. Specifically, on 3/6/2019 the following conditions were observed: A. While compounding the sterile drug, your firm's pharmacist failed to disinfect non-sterile drug components, Phentolamine Mesylate USP, Mannitol USP, and Papaverine HCL, prior to removal from where weighed and staged on the stainless-steel table in ISO 8 anteroom and prior to entry …

    Contains “aseptic*”Read the Form 483 →

  10. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 5

    Disinfecting agents used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, your firm pharmacist was observed using an unlabeled bottle of non-sterile [redacted] to disinfect the ISO 5 hood aseptic processing surfaces. Unlabeled bottles of non-sterile [redacted] were found in the pharmacy's ISO 8 anteroom and ISO 7 cleanroom. Your firm failed to provide records and/or surface disinfectant/decontaminant documentation …

    Contains “ISO 5”Read the Form 483 →

  11. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 6

    The use of sporicidal agents in the cleanrooms and ISO 5 classified aseptic processing area was inadequate. Specifically, your firm failed to validate the use of [redacted] cleaner as a sporicidal agent used in your firm's cleaning program.

    Contains “ISO 5”Read the Form 483 →

  12. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 7

    Your facility design allowed the influx of poor quality air into a higher classified area. Specifically, your firm air returns are adjacent to your HEPA filters in the ceiling and ISO 7 cleanroom used in the production. Your firm failed to provide documents (smoke study) in support of adequate air circulation in the prevention of an influx of poor quality air into a higher classified area.

    Contains “smoke stud*”Read the Form 483 →

  13. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 8

    Laboratory test equipment used in the preparation and testing of collected samples are inadequate. Specifically, your firm uses a [redacted model] for the incubation of collected media-fills. The unit fails to have adequate temperature and related humidity controls to perform and control these environmental conditions.

    Contains “media fill*”Read the Form 483 →

  14. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 10

    ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow was not verified under operational conditions. Specifically, your firm's clean room re-certification tests dated [redacted] were documented as being performed while the pharmacy contract clean room certifier reported that he does not recertify the clean room while pharmacy is performing media fills and/or compounding actual sterile drug …

    Contains “ISO 5”Read the Form 483 →

  15. Front Door Pharmacy, LLC dba Pure PharmacyInspection ended Mar 18, 2019 · FEI 3012937475 · Observation 11

    The ISO-classified areas have difficult-to-clean, particle-generating surfaces. Specifically, during a walk-through on 2/25/2019, foreign particulate matter was observed on top of [redacted] which was not in service. Foreign particulate matter was observed in the ISO 7 production area adjacent to the ISO 5 hood. The firm failed to prevent particle generation or provide adequate cleaning for visibly dirty equipment or surfaces.

    Contains “ISO 5”Read the Form 483 →

  16. Intrathecal Compounding Specialist, LLCInspection ended Feb 14, 2019 · FEI 3006372310 · Observation 3

    The use of sporicidal agents in the cleanrooms and ISO 5 area is inadequate or infrequent. Specifically, you do not use a sporicidal cleaner at a minimum monthly.

    Contains “ISO 5”Read the Form 483 →

  17. Intrathecal Compounding Specialist, LLCInspection ended Feb 14, 2019 · FEI 3006372310 · Observation 4

    Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worse-case activities and conditions that provide a challenge to aseptic operations. Specifically, your media fills include [(b) (4)] with minimal manipulations and do not include syringes at all or the number of syringes produced for stock solutions.

    Contains “media fill*”Read the Form 483 →

  18. Intrathecal Compounding Specialist, LLCInspection ended Feb 14, 2019 · FEI 3006372310 · Observation 5

    Personnel donned gowning apparel improperly, that may have caused the gowning apparel to become contaminated. Specifically, you don non-sterile face masks in an uncontrolled environment which do not cover your entire face and lean into the ISO 5 hoods during aseptic operations.

    Contains “gown*”Read the Form 483 →

  19. Dorneyville PharmacyInspection ended Sep 28, 2018 · FEI 3005231215 · Observation 1

    The final containers/closures used for drug product intended to be sterile were not sterilized. Specifically, Finished product containers, closures, product contact beakers, and mixing rods which are treated for sterilization are wrapped in aluminum foil and are stored in an ISO 7 room without an established hold time to ensure that these items remain sterile. This observation is a repeated objectionable condition reported during the last …

    Contains “sterili*”Read the Form 483 →

  20. New Vitalis Pharmacy LLC dba New Vitalis PharmacyInspection ended Sep 7, 2018 · FEI 3014391500 · Observation 2

    Visual inspection of finished drug products prior to distribution is not adequately performed. Specifically, Your firm sterilized Testosterone Cypionate 200 MG/ML in Grapeseed Oil injectable lots AL-07192018@906 and AL-08072018@901 at [illegible] for [illegible] minutes, respectively on 07/24/18 and 08/07/18. Your firm stated that 100% visual checks are performed on each lot prior to labeling and dispensing or distribution to your patient. …

    Contains “sterili*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.