Intrathecal Compounding Specialists, LLC
206a Jacobs Run, Scott, Louisiana, United States
FEI 3006372310
FDA has 3 inspections on file for Intrathecal Compounding Specialists, LLC in Scott, Louisiana (FEI 3006372310), from 2017 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection. They are listed below.
The most recent OAI inspection ended on Feb 14, 2019. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: FDCA 501(a)(2)(A).
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2017–2021
- 2 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Disinfectant contact time
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection.
- FDCA 501(a)(2)(A)
Actionable microbial contamination, ISO 5 area
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.
- FDCA 501(a)(2)(A)
Disinfecting and cleaning agents, ISO 5 area
Disinfecting agents and cleaning pads and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Air equipment change during production
The ISO classified area underwent a change in air equipment that [(b) (4)] and you continued to produce and distribute sterile drugs. Specifically, you replaced the [(b) (4)] to the sterile suite on February 6, 2019, due to issues with maintaining the coolness of the air [(b) (4)] on multiple occasions). Your firm continued to produce and distribute sterile drugs while and after the [(b) (4)] to the sterile suite was replaced without adequate cleaning and recertification following the installation.
- Observation 2
Inadequate pressure differentials observed
Inadequate pressure differentials between higher quality air room and lower quality air rooms were observed. Specifically, you had negative or zero pressure for short periods of time in the buffer room (ISO 7) and anteroom (ISO 8) on January 2, 2019. Additionally, there were multiple times on twenty-one days when the pressure was lost in the [(b) (4)] room from November 28, 2018 to December 28, 2018. You have no pressure data for January 24, 2019 to February 7, 2019 between the anteroom and [(b) (4)] room as well as when the [(b) (4)] was being changed.
Show observations 3 to 5
- Observation 3
Infrequent use of sporicidal agents
The use of sporicidal agents in the cleanrooms and ISO 5 area is inadequate or infrequent. Specifically, you do not use a sporicidal cleaner at a minimum monthly.
- Observation 4
Inadequate media fill simulation
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worse-case activities and conditions that provide a challenge to aseptic operations. Specifically, your media fills include [(b) (4)] with minimal manipulations and do not include syringes at all or the number of syringes produced for stock solutions.
- Observation 5
Improper gowning and mask use
Personnel donned gowning apparel improperly, that may have caused the gowning apparel to become contaminated. Specifically, you don non-sterile face masks in an uncontrolled environment which do not cover your entire face and lean into the ISO 5 hoods during aseptic operations.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Non-microbial contamination, production area
Non-microbial contamination was observed in your production area.
- FDCA 501(a)(2)(A)
Actionable microbial contamination, ISO 5 area
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.
- FDCA 501(a)(2)(A)
Personnel in aseptic processing, cleanroom gowning
Personnel engaged in aseptic processing were observed leaving and re-entering the cleanroom from non-classified areas without first replacing gowning apparel.
- FDCA 501(a)(2)(A)
Disinfectant contact time
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection.
- FDCA 501(a)(2)(A)
Exposure of personnel in aspectic processing
Personnel engaged in aseptic processing were observed with exposed hair and exposed mouth.
Show 5 more citations
- FDCA 501(a)(2)(A)
Personnel contact outside ISO 5 area
Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves.
- FDCA 501(a)(2)(A)
Disinfecting materials, aseptic processing area
Equipment was and Materials or supplies were not disinfected prior to entering the aseptic processing areas.
- FDCA 501(a)(2)(A)
Highly potent drugs, prevention of cross-contamination
You produced highly potent drugs without providing adequate segregation, cleaning of work surfaces and cleaning of personnel to prevent cross-contamination.
- FDCA 501(a)(2)(A)
Improper gowning, contamination
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean and particle-generating equipment or surface.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006372310 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006372310. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.