Skip to content

Intrathecal Compounding Specialist, LLC Form 483, February 2019

FDA issued this Form 483 to Intrathecal Compounding Specialist, LLC in Scott, Louisiana (FEI 3006372310) at the end of a drug inspection that ended February 14, 2019. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Apr 30, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 14, 2019
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Apr 30, 2019
75 days after the inspection
Facility
FEI 3006372310
Scott, Louisiana

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Air equipment change during production

    The ISO classified area underwent a change in air equipment that [(b) (4)] and you continued to produce and distribute sterile drugs. Specifically, you replaced the [(b) (4)] to the sterile suite on February 6, 2019, due to issues with maintaining the coolness of the air [(b) (4)] on multiple occasions). Your firm continued to produce and distribute sterile drugs while and after the [(b) (4)] to the sterile suite was replaced without adequate cleaning and recertification following the installation.

  2. 2

    Inadequate pressure differentials observed

    Inadequate pressure differentials between higher quality air room and lower quality air rooms were observed. Specifically, you had negative or zero pressure for short periods of time in the buffer room (ISO 7) and anteroom (ISO 8) on January 2, 2019. Additionally, there were multiple times on twenty-one days when the pressure was lost in the [(b) (4)] room from November 28, 2018 to December 28, 2018. You have no pressure data for January 24, 2019 to February 7, 2019 between the anteroom and [(b) (4)] room as well as when the [(b) (4)] was being changed.

  3. 3

    Infrequent use of sporicidal agents

    The use of sporicidal agents in the cleanrooms and ISO 5 area is inadequate or infrequent. Specifically, you do not use a sporicidal cleaner at a minimum monthly.

  4. 4

    Inadequate media fill simulation

    Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worse-case activities and conditions that provide a challenge to aseptic operations. Specifically, your media fills include [(b) (4)] with minimal manipulations and do not include syringes at all or the number of syringes produced for stock solutions.

  5. 5

    Improper gowning and mask use

    Personnel donned gowning apparel improperly, that may have caused the gowning apparel to become contaminated. Specifically, you don non-sterile face masks in an uncontrolled environment which do not cover your entire face and lean into the ISO 5 hoods during aseptic operations.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterSep 16, 2020CDER · 580 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3006372310, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.