Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Celltrion Inc.Inspection ended Jul 17, 2018 · FEI 3005241015 · Observation 4
Procedures describing the calibration of instruments, apparatus, gauges, and recording devices are deficiently written or followed. Specifically, Your firm does not adequately monitor the incubator rooms used to incubate environmental, media fill, and sterility samples. Your most recent temperature mapping study determined hot and cold spots for the incubators; however your routine temperature monitoring gauge is not located in these areas.
Contains “media fill*”Read the Form 483 →
Drug Depot, Inc. dba APS PharmacyInspection ended Jul 13, 2018 · FEI 3010621916 · Observation 1
Personnel were observed conducting aseptic manipulations that blocked the movement of first pass air around an open unit, whether before or after it is filled with sterile product. Specifically, on 07/09/2018 I observed a sterile technician filling vials of Testosterone Cypionate/ Anastrozole*GS*Oil200MG/0.5MG/MLRM Injectable lot number 486380, in (b)(4) laminar ISO 5 classified bio-safety cabinet, break first pass unidirectional airflow at least …
Contains “aseptic*”Read the Form 483 →
Drug Depot, Inc. dba APS PharmacyInspection ended Jul 13, 2018 · FEI 3010621916 · Observation 2
The ISO-classified area has difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, caulking around joints of the ISO 5 area between the laminar flow hood and (b)(4) and on ceilings in the non-hazardous and hazardous areas were not smooth.
Contains “ISO 5”Read the Form 483 →
Drug Depot, Inc. dba APS PharmacyInspection ended Jul 13, 2018 · FEI 3010621916 · Observation 3
Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, since December 2017 lots of hazardous Human Chorionic Gonadotropin (HCG) were filled and (b)(4) in the non-hazardous ISO 5 classified area of the facility.
Contains “ISO 5”Read the Form 483 →
FH Investments Inc. dba Asteria HealthInspection ended Jul 10, 2018 · FEI 3010348724 · Observation 1
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, during (b) (4) sterilization validation, a. The bioburden and sterility method validation and suitability testing used for dose verification testing were not performed using testosterone and estradiol pellets made by your firm. b. The sterility and bioburden testing …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
FH Investments Inc. dba Asteria HealthInspection ended Jul 10, 2018 · FEI 3010348724 · Observation 2
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, sterility testing of hormone pellets during (b) (4) only provides information for the exterior surfaces of the implantable pellets. There is no evaluation of the entire pellet.
Contains “sterili*”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 1
Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves. Specifically, during production of Lido/Dex/Hep/Gent/Sodium Bicarbonate Bladder Irrigation Solution lot 051518-1CR for Rx (b)(6) the technician was observed touching non-sterile components and equipment on the cart outside of the ISO 5 …
Contains “ISO 5”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 2
Personnel engaged in aseptic processing were observed with exposed hair. Specifically, during production of Lido/Dex/Hep/Gent/Sodium Bicarbonate Bladder Irrigation Solution lot 051518-1CR for Rx (b)(6), Cefazolin 50 mg/mL Ophthalmic solution lot 151618-1CR for Rx (b)(6), and Tobramycin 14 mg/mL Ophthalmic solution lot 151618-2CR for Rx (b)(6) the technician's hair was observed as not fully covered while working in the ISO 5 hood.
Contains “aseptic*”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 3
Equipment and materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, the technician was repeatedly observed handling packaged and unpackaged components with bare hands before and while disinfecting the components with (b)(4) immediately before introduction into the pass through. In addition, during production of Lido/Dex/Hep/Gent/Sodium Bicarbonate Bladder Irrigation Solution lot 051518-1CR for Rx …
Contains “aseptic*”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 4
The use of sporicidal agents in the ISO 5 classified aseptic processing area was inadequate. Specifically, the (b)(4) and the (b)(4) used to disinfect the ISO 5 area and the clean room are not effective as sporicidal agents at the specified concentration and contact time.
Contains “ISO 5”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 5
Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, the (b)(4) the firm prepares and uses in the ISO 5 hood is not sterile. Non-sterile lint free wipes are used to clean and disinfect the ISO 5 hood. The technician uses these non-sterile wipes that are kept in a stack, with no covering, on a cart in the clean room.
Contains “ISO 5”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 6
Your facility was designed and/or operated in a way that permits poor flow of personnel and materials. Specifically, The Prep room is unclassified and is where in-house sterilized glassware used in the aseptic preparation of drug products is stored. The technician was observed to move repeatedly between the ISO 8 classified gowning room and unclassified areas to retrieve components and transit through plastic curtains that are also contacted by …
Contains “sterili*”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 7
Non-microbial contamination was observed in your production area. Specifically, white residue was observed on the face panel of the HEPA filter supplying air to the ISO 5 area. In addition, the floor of the ISO 7 clean room has visible dirt, stains, or residue that are not removed during routine cleaning.
Contains “ISO 5”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 8
Procedures designed to identify and prevent insanitary conditions are not established and followed by your firm. Specifically, 1. Your firm did not ensure appropriate certification of your aseptic processing areas. For example, a. During certification of your aseptic processing area on 02/12/18, testing showed pressure differential failure between the gowning room and the unclassified general pharmacy. This failure was not corrected until …
Contains “aseptic*”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 9
The ISO 5 classified aseptic processing areas and segregated production areas surrounding the ISO 5 classified aseptic processing area contained dust-collecting overhangs without adequate and frequent cleaning. Specifically, there are horizontal, flat surfaces above the ISO 5 hood. Those are not cleaned during routine cleaning, and the hired (b)(4) cleaning services do not include the ISO 5 hood. In addition, there are other such surfaces in the …
Contains “ISO 5”Read the Form 483 →
Eagle Pharmacy Inc.Inspection ended May 18, 2018 · FEI 3011688532 · Observation 2
… There equivalent between the different 6JJ 4) Testosterone Cypionate is b) sterilized using these Medroxyprogesterone Acetate, and Triamcinolone Acetonide.
Contains “sterili*”Read the Form 483 →
Eagle Pharmacy Inc.Inspection ended May 18, 2018 · FEI 3011688532 · Observation 3
Aseptic processing areas are deficient regarding systems for the aseptic conditions. Specifically, there is [illegible] used to monitor pressure differentials, temperature, and relative [illegible] classified areas used for sterile compounding.
Contains “aseptic*”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 1
The (b)(4) intended to render final product sterile is not adequate to accomplish sterilization and/or is not pharmaceutical grade. Specifically, a. Your firm uses the (b)(4) when compounding large volume batches of sterile finished product. The (b)(4) does not appear to be pharmaceutical grade and the labeling for the (b)(4) states "Do not use these systems in direct patient care applications." There is no (b)(4) testing method for the (b)(4). …
Contains “sterili*”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 2
… Your firm uses the (b)(4) for both (b)(4) sterilization and sterilization of container-closures, such as stoppers and final product vials. Effectiveness of (b)(4) is verified using (b)(4) Biological Indicators. The manufacturer recommends incubation conditions of (b)(4) for (b)(4). The incubator is not calibrated to ensure the temperature can maintain (b)(4). The (b)(4) does not contain a visual thermometer to monitor the temperature during BI …
Contains “sterili*”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 3
The final containers/closures used for drug product intended to be sterile have not been sterilized or depyrogenated. Specifically, a. Your firm does not depyrogenate the non-sterile stoppers and vials before conducting filling operation for all aseptically filled drug products. b. Your firm does not depyrogenate the non-sterile stoppers and vials before conducting filling operation for all (b)(4) sterilized pellet drug products.
Contains “sterili*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.