Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 4
Disinfecting agents and cleaning pads or wipes used in the ISO 5 area are not sterile. Specifically, To clean and disinfect the ISO-5 Laminar Air Flow Hood (LAFH), the firm uses non-sterile (b)(4) Wipers, non-sterile (b)(4) Dry Wipes, non-sterile (b)(4), non-sterile (b)(4) and sterile (b)(4) spray.
Contains “ISO 5”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 5
The use of sporicidal agents in the cleanrooms and/or ISO 5 areas is inadequate. Specifically, Your firm has not established sufficient contact time for all disinfectants use in the cleanroom. Your firm failed to follow manufacturer's recommended contact times for the disinfectants used in the controlled environments. For example, for non-sporicidal agent (b)(4) the manufacturer recommends a contact surface time of (b)(4). Your daily …
Contains “ISO 5”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 6
You produced hazardous drugs without providing adequate cleaning of utensils to prevent cross-contamination. Specifically, Your firm uses non-dedicated glassware and utensils to weigh and mix non-sterile hazardous and non-hazardous ingredients, in preparation for aseptic filling operations. Examples of hazardous ingredients used in your facility include Testosterone Cypionate and Alprostadil.
Contains “aseptic*”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 7
Non-sterilized or non-depyrogenated tools or temporary container were used in sterile production. Specifically, Your firm uses glassware and utensils to weigh and mix non-sterile ingredients, in preparation for aseptic filling operations. Your firm does not adequately clean the glassware and utensils to prevent cross-contamination. Glassware, spatulas, and mixing bars are washed in a dishwasher using (b)(4). Your firm has not conducted any …
Contains “sterili*”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 8
Environmental monitoring in your aseptic processing areas is not adequate. Specifically, a. Review of the last (b)(4) Environmental Monitoring report, dated 11/30/17, revealed that Micrococcus species and Aspergillus was detected when viable air sampling was conducted in the ISO-5 Laminar Air Flow Hood. As a corrective action, your firm performed cleaning (b)(4) times in the controlled environment, and air sampling was repeated. An investigation …
Contains “aseptic*”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 9
Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, a. Sterile drug filling is conducted inside the ISO 5 core of Laminar Air Flow Hood (LAFH). The evaluation of unidirectional airflow (e.g., smoke studies) for microbiological contamination was not performed under dynamic conditions in the ISO 5 LAFH, which is located in an ISO 7 environment. b. During filling operations, we …
Contains “ISO 5”Read the Form 483 →
One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 10
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, (b)(4) media fill testing is performed, but are not designed to simulate firm's routine aseptic operation. a. Your firm conducts Media Fill in (b)(4). A commercially purchased kit containing (b)(4) are used to conduct media fills. The …
Contains “media fill*”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 1
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, on February 13, 2018 during the machine set-up and filling preparation for ®® | injection lot # ®®, I observed dirty ®® | with black stains on the filling machine and mentioned it to the management. No action was taken by the management on that day. On Feb. 14, 2018, I observed that the filling is in process …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 2
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, on the filling machine in suite § which are used for aseptic interventions during the filling operation inside the aseptic fill zone (grade A) had obvious built-up dirt and stains. These ®® | are used for production of injection …
Contains “aseptic*”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 3
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the qualification of the vial washer and in®® block suite, that are used for washing and sterilizing of § mL vials are not adequate. For example, qualification studies: a) for vial washer failed to demonstrate if vial washer (Eq. Id. # L-PR-QASHM-001) is able to remove …
Contains “sterili*”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 5
… failed to demonstrate the efficacy of the 2 process, which is part of your cleaning activities, to eliminate contaminants in the hard to reach areas in the aseptic fill and areas (grade A & B).
Contains “aseptic*”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 6
… :P@ times with ®® and cloth without paying attention to the black stains and obvious black marks on the ®® These ®® were in use from June 2017 and had been sterilized 5 times.
Contains “sterili*”Read the Form 483 →
Option Care Enterprises Inc. dba Option CareInspection ended Feb 8, 2018 · FEI 3012188090 · Observation 1
1. Poor aseptic practices were observed. Specifically, on the morning of 01/25/18 while watching a Technician perform the sterile production manipulations to make the bags for Rx o 6 SN o ~ TPN~ b) (4 ml I observed: A. During the required 15 ; addition of the drug component sodium acetate 2 meq/ml to the bag of TPN sterile drug product, the technician placed a finger directly on the junction between the uncapped injection port of the TPN bag and …
Contains “aseptic*”Read the Form 483 →
Option Care Enterprises Inc. dba Option CareInspection ended Feb 8, 2018 · FEI 3012188090 · Observation 2
2. Disinfecting agents, cleaning pads, and cleaning wipes used for sterile drug production were not always sterile or controlled in a manner as to maintain sterility. Specifically. A. Your firm uses o (~ wipes labeled in part 4) I 11..-'-l..-"-~~~~~~~~~~~~~~~~~~~~~~-' to disinfect the exterior of equipment, components, and container/closures before placing into the ISO 5 cabinets during aseptic processing. The wipes are not labeled as sterile. …
Contains “sterili*”Read the Form 483 →
Option Care Enterprises Inc. dba Option CareInspection ended Feb 8, 2018 · FEI 3012188090 · Observation 4
4. Media fills were not performed under the most challenging or stressful conditions. Specifically, your procedures for media fills do not fully emulate the number and type of connections used to produce all parenteral nutrition drug products using the ) (~) b) (4). Option Care utilizes an b 4 b) (4) to produce Total Parenteral Nutrition drug products such as Rx b) (6) compounded on 12/28/2017. The o 4 requires the ~) b) (4) during initial set-up …
Contains “media fill*”Read the Form 483 →
Shilpa Medicare LimitedInspection ended Nov 30, 2017 · FEI 3009876430 · Observation 5
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. A. During the watching of ®@ injection production on 21 Nov. 2017, I noted the firm was not documenting all interventions. I observed 3 interventions between the weight check ®@ and ®@. Only one of these interventions was documented. B. Media fills are performed following SOP/QAD/GEN/043-06 Procedure …
Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →
Accurate Rx Pharmacy Consulting, LLC dba Accurate Rx PharmacyInspection ended Aug 14, 2017 · FEI 3013446837 · Observation 1
Observation 1: Your ISO5 classified workstation where sterile product are prepared is located within a non-classified room. Specifically, A. Your (15)(4) "compounding aseptic (15)(4)" is not located in a controlled environment/room in order to prevent the risk of contamination. On 7/31/2017, during the production of saline water bags, the (15)(4) was observed to be equipped with (15)(4) and is therefore not completely enclosed to the environment. …
Contains “aseptic*”Read the Form 483 →
D&S Enterprises, LLC dba Miller’s Health Mart PharmacyInspection ended Aug 9, 2017 · FEI 3013675130 · Observation 1
Observation 1 Your Pharmacy is producing sterile drugs in Compound buffer room. In addition, injectable sterile products ing Aseptic Isolator (CAI) that is located in an unclassified are assigned a BUD of greater than 12 hours. For example, your pharmacy produced approximately a total of combined Morphine and Hydrocodone prescriptions for the year 2016 that were assigned a BUD of 48 hours at room temperature and 14 days in the refrigerator.
Contains “aseptic*”Read the Form 483 →
I.V. Specialty Ltd.Inspection ended Jul 28, 2017 · FEI 3010836489 · Observation 1
OBSERVATION 1 Vermin was observed present in areas immediately adjacent to your production area. A dead spider was observed in HEPA filter located in the ceiling of the ISO 7 clean room, approximately 10 feet from the ISO 5 laminar air flow (LAF) hood used for sterile drug processing.
Contains “ISO 5”Read the Form 483 →
I.V. Specialty Ltd.Inspection ended Jul 28, 2017 · FEI 3010836489 · Observation 2
OBSERVATION 2 The ISO-classified areas have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. A. LAF Hood has loose panels covering a light fixture directly above aseptic processing area creating a difficult to clean surface. This equipment is intended to create an ISO 5 aseptic processing environment for sterile drugs. B. LAF Hood has a loose access panel immediately below processing table surface that creates a …
Contains “LAF*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.