Accurate RX Pharmacy Consulting LLC
103 Corporate Lake Dr Ste B, Columbia, Missouri, United States
FEI 3013446837
FDA has 3 inspections on file for Accurate RX Pharmacy Consulting LLC in Columbia, Missouri (FEI 3013446837), from 2017 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Sep 19, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2017–2021
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Non-sterile cleaning agents used
Disinfecting agents and cleaning wipes and pads used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, we observed your Pharmacist-in-Charge cleaning your ISO 5 laminar air flow hood on 7/8/2021. A. During these cleaning activities, we observed the use of non-sterile (b) (4) wipes which were used specifically to clean the ISO 5 laminar air flow hood. B. During these cleaning activities, we observed the use of non-sterile (b) (4) used along with the non-sterile wipes.
- Observation 2
Difficult-to-clean surfaces present
The ISO 5 classified aseptic processing areas had difficult to clean equipment or surfaces. Specifically, A. During cleaning, you did not clean an approximate [illegible] radius porthole located on the right sidewall of your laminar air flow hood. B. During cleaning, you did not clean all surfaces of the outer packaging of (b) (4) wipes residing in the laminar air flow hood.
Show observation 3
- Observation 3
Materials not disinfected before entry
Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, you did not disinfect your sterile bottle of (b) (4) before transferring from your ISO 7 room into your ISO 5 laminar air flow hood.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Location, ISO 5 classified area
The ISO 5 classified aseptic processing area was located within a non-classified room (segregated production area).
- FDCA 501(a)(2)(A)
Disinfecting and cleaning agents, ISO 5 area
Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.
- FDCA 501(a)(2)(A)
No sporicidal agents, cleanroom and ISO 5 area
Sporicidal agents were not used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
ISO5 workstation not in controlled room
Observation 1: Your ISO5 classified workstation where sterile product are prepared is located within a non-classified room. Specifically, A. Your (15)(4) "compounding aseptic (15)(4)" is not located in a controlled environment/room in order to prevent the risk of contamination. On 7/31/2017, during the production of saline water bags, the (15)(4) was observed to be equipped with (15)(4) and is therefore not completely enclosed to the environment. Additionally, (b)(4) is not used every day and it is turned off when it is not in use. (15)(4) for cleaning and disinfection. B. The ISO5 classified area is in close proximity to the sink and no barriers exists between the sink and the "compounding aseptic (15)(4)" to prevent risk of contamination.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013446837 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013446837. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.