Dorneyville Pharmacy
3330 Hamilton Blvd, Allentown, Pennsylvania, United States
FEI 3005231215
FDA has 2 inspections on file for Dorneyville Pharmacy in Allentown, Pennsylvania (FEI 3005231215), from 2016 to 2018. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Jan 7, 2016. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2016–2018
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Sterilization/storage of sterile containers
The final containers/closures used for drug product intended to be sterile were not sterilized. Specifically, Finished product containers, closures, product contact beakers, and mixing rods which are treated for sterilization are wrapped in aluminum foil and are stored in an ISO 7 room without an established hold time to ensure that these items remain sterile. This observation is a repeated objectionable condition reported during the last inspection.
- Observation 2
Use of non-pharmaceutical grade components
You used a non-pharmaceutical grade component in the formulation of a drug product during the compounding of non-sterile drug products. Specifically, a. The firm fails to use (b)(4). For example, Potassium Bromide (VET) Oral 300 mg/mL solution, Buprenorphine 0.3 mg/mL liquid, and Dexamethasone 0.5 mg/mL oral rinse. b. The firm has not conducted microbiological testing of the [illegible] used in non-sterile production. This has been used as a component during the production of Potassium Bromide (VET) Oral 300 mg/mL solution, Buprenorphine 0.3 mg/mL liquid, and Dexamethasone 0.5 mg/mL oral rinse.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Components withheld from use pending release
Each lot of drug product containers and closures is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Buildings not maintained in good state of repair
Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Show 9 more citations
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Written distribution procedure
Written distribution procedures are not established .
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed .
Retest of approved components/containers/closures
Approved drug product containers and closures are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing of drug products is not appropriate for the duties they perform.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function , current good manufacturing practices and written procedures required by current good manufacturing practice regulations .
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.28Personnel responsibilities1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.58Maintenance1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.87Retesting of approved components, drug product containers, and closures1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.150Distribution procedures1 of 1
Show all 12
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.167Special testing requirements1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3005231215 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3005231215. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.