Aseptic processing and sterility assurance in FDA Form 483 observations
Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 620
- Each quoted below
- Form 483s
- 180
- Posted by FDA
- Facilities
- 164
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 169 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 3 |
| 2013 | 1 |
| 2014 | 15 |
| 2015 | 15 |
| 2016 | 27 |
| 2017 | 41 |
| 2018 | 57 |
| 2019 | 74 |
| 2020 | 7 |
| 2021 | 53 |
| 2022 | 54 |
| 2023 | 37 |
| 2024 | 20 |
| 2025 | 44 |
| 2026 | 169 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)
The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 620 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Abilene Nuclear LLC dba National Central PharmacyInspection ended Nov 7, 2019 · FEI 3004819860 · Observation 1
OBSERVATION 1 Personnel engaging in aseptic processing was observed with exposed skin. Specifically, your firm's pharmacy manager was observed during the production of the non-patient specific sterile drug product, EPI-Shugarcaine Su/F Ophth 1 ml/vial, (b)(6), as having his head, partially exposed facial skin, inside LAF Hood.
Contains “aseptic*”Read the Form 483 →
Abilene Nuclear LLC dba National Central PharmacyInspection ended Nov 7, 2019 · FEI 3004819860 · Observation 2
OBSERVATION 2 Materials or supplies were not disinfected prior to entering the ISO 5 LAF Hood. Specifically, your pharmacy manager failed to adequately disinfect materials transferred from the ISO 7 Cleanroom into LAF Hood which was later used in production. For example, on 10/30/2019, I observed your pharmacy [illegible] 'Office Use Only', EPI-Shugarcaine Su/F Ophth 1 ml/vial, 11/13/2019. While producing this lot of sterile drug product, I …
Contains “ISO 5”Read the Form 483 →
Abilene Nuclear LLC dba National Central PharmacyInspection ended Nov 7, 2019 · FEI 3004819860 · Observation 3
OBSERVATION 3 Personnel touched equipment or other surfaces located outside the ISO 5 area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves. Specifically, your firm's pharmacy failed to disinfect sterile gloves prior to re-entry into ISO 5 LAF hood while aseptically processing the sterile drug product, EPI-Shugarcaine Su/F Ophth 1 ml/vial. After collecting additional supplies in the ISO 7 Cleanroom …
Contains “ISO 5”Read the Form 483 →
Abilene Nuclear LLC dba National Central PharmacyInspection ended Nov 7, 2019 · FEI 3004819860 · Observation 4
OBSERVATION 4 Personnel placed equipment/supplies in an area that blocked the movement of first pass airflow within the LAF hood, either before or after it was filled with sterile product. Specifically, your firm's pharmacy manager failed to place supplies to maintain first pass airflow within LAF Hood during aseptic processing. For example, during the aseptic processing of the sterile drug product, EPI-Shugarcaine Su/F Ophth 1 ml/vial, …
Contains “LAF*”Read the Form 483 →
Abilene Nuclear LLC dba National Central PharmacyInspection ended Nov 7, 2019 · FEI 3004819860 · Observation 6
OBSERVATION 6 Disinfecting agents and cleaning pads or wipes used are not appropriate for use in the ISO 5 LAF hood designated for the production of sterile drug product. Specifically, your firm is using the non-sterile cleaning product, (b)(4), in the LAF Hood designated for the production of sterile drug product.
Contains “ISO 5”Read the Form 483 →
Abilene Nuclear LLC dba National Central PharmacyInspection ended Nov 7, 2019 · FEI 3004819860 · Observation 7
OBSERVATION 7 Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, your firm's procedure, Media Fill Challenge, Document #6.36, uses a (15)(4) [illegible]. (15)(4) Your firm's PIC reported the manipulations and complexity performed using the kit is representative of those performed during …
Contains “media fill*”Read the Form 483 →
SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 1
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, your method allows for [(o) (4) with the (o) (4) for sterility testing which is not equivalent to USP <71>.
Contains “sterili*”Read the Form 483 →
SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 3
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, you have never conducted an audit trail review of the SCANRDI system since you began using it in 2013 for sterility analysis nor do you have a procedure for conducting an audit trail review. Additionally, an employee who performs most of …
Contains “sterili*”Read the Form 483 →
SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 6
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions. Specifically, employees responsible for the sterility analysis by Scan RDI are two months late in their [illegible] recertification and continue to process sterility analysis using Scan RDI.
Contains “sterili*”Read the Form 483 →
Farmakeio Outsourcing LLCInspection ended Oct 30, 2019 · FEI 3014982757 · Observation 3
Aseptic processing areas are deficient regarding the system of your facility. Specifically, you are not monitoring the environmental conditions for each batch of product you manufacture. Examples of compounded drug product lots that were not environmentally monitored during production: • BR, Lot 176, and BR, Lot 178
Contains “aseptic*”Read the Form 483 →
Aurobindo Pharma Ltd. Unit 5Inspection ended Oct 28, 2019 · FEI 3004051616 · Observation 2
Equipment for adequate control over micro-organisms is not always provided when appropriate for the manufacture, processing, and packing of drug substances. a) Filling equipment (b) Block Module (b)(1) (grade A) is located in a position where aseptic procedures for operators during filling include bending down and squatting, which may result in bellowing of viable and non-viable particulate from personnel gowning during these activities having a …
Contains “aseptic*”Read the Form 483 →
Aurobindo Pharma Ltd. Unit 5Inspection ended Oct 28, 2019 · FEI 3004051616 · Observation 3
The aseptic processing area is deficient regarding the system for monitoring environmental conditions. During aseptic operations in Block Module (b)(1) in grade A where sterilized stoppers are unsealed and transferred to the filling area (along with depyrogenated (b)(4) canisters), there is an absence of continuous monitoring of viables in the immediate proximity of exposed stopper packaging materials within the airflow of intervention activities …
Contains “aseptic*”Read the Form 483 →
Aurobindo Pharma Ltd. Unit 5Inspection ended Oct 28, 2019 · FEI 3004051616 · Observation 4
Process validation does not always include inclusion and establishment of all process parameters that should be controlled for reproducible operations. For example: a) Validation of (b)(4) and (b)(4) bag sealing processes (used in package sealing of non-sterile bulk drugs) and validation of (b) sealing of packaged and sterilized gowning (used in aseptic operations) and sterilized stoppers (used in package sealing of sterile bulk drugs) are not …
Contains “sterili*”Read the Form 483 →
SBH Medical LTDInspection ended Sep 30, 2019 · FEI 3015242029 · Observation 1
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, You do not have media fill for (b)(1), representing the most manipulative conditions in your firm. Add Continuation Page
Contains “media fill*”Read the Form 483 →
Snyder Mark Drugs Roselle, Inc. dba Mark Drugs PharmacyInspection ended Sep 27, 2019 · FEI 3004486825 · Observation 1
OBSERVATION 1 ISO 5 classified areas were not certified under dynamic conditions. Specifically, The certification documents for your ISO 5 aseptic processing areas do not describe the dynamic conditions under which they were tested. In addition, no smoke study was conducted to show that the air is moving unidirectionally for your ISO 5 aseptic processing areas while simulating your current production and operating processes of the laminar flow …
Contains “ISO 5”Read the Form 483 →
Snyder Mark Drugs Roselle, Inc. dba Mark Drugs PharmacyInspection ended Sep 27, 2019 · FEI 3004486825 · Observation 2
OBSERVATION 2 Wipes used in the ISO 5 aseptic processing areas are not sterile. Specifically, On September 17th, 2019, we observed an employee use non-sterile wipes in the ISO 5 Hood while aseptically processing of Atropine Sulfate 0.01% Ophthalmic with lot #091719TSEM, and to clean the hood afterwards. Additionally, on September 19th, 2019, we observed an employee use non-sterile wipes in the ISO 5 hood while performing the end of day cleaning.
Contains “ISO 5”Read the Form 483 →
Snyder Mark Drugs Roselle, Inc. dba Mark Drugs PharmacyInspection ended Sep 27, 2019 · FEI 3004486825 · Observation 3
OBSERVATION 3 Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, 1. You do not simulate the maximum number of activities which occur during your production operations. 2. You do not simulate the worst-case activities during your production operations. 3. You do not simulate the maximum …
Contains “media fill*”Read the Form 483 →
Isorx, Corp.Inspection ended Sep 18, 2019 · FEI 3006624492 · Observation 1
OBSERVATION 1 Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, On 9/11/2019, you removed a pre-sterilized/depyrogenated syringe from the ISO 5 laminar flow hood and cleanroom, which exposed the syringe to unclassified air in your lab space. You then returned this syringe to your ISO 5 laminar flow hood. This syringe was used in the production of 1-123 Metaiodobenzylguanidine (MIBG) USP, Rx …
Contains “aseptic*”Read the Form 483 →
Isorx, Corp.Inspection ended Sep 18, 2019 · FEI 3006624492 · Observation 2
OBSERVATION 2 Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, On 9/11/2019, you used wipes to clean the interior of your ISO 5 laminar flow hoods that were not labeled as sterile. These wipes are used for your pre-operational cleaning of the laminar flow hood. This ISO 5 laminar flow hood was used to produce 1-123 Metaiodobenzylguanidine (MIBG) Rx [illegible], lot …
Contains “ISO 5”Read the Form 483 →
Isorx, Corp.Inspection ended Sep 18, 2019 · FEI 3006624492 · Observation 3
OBSERVATION 3 Sporicidal agents were not used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area. Specifically, You do not require a specific contact time for the [illegible] sporicidal that you apply to your ISO 5 laminar flow hoods. This sporicidal was used to clean the laminar flow hood used to produce 1-123 Metaiodobenzylguanidine (MIBG) Rx [illegible], lot [illegible] MIBG, a sterile drug product.
Contains “ISO 5”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.113Control of microbiological contaminationIn this theme's rule66
- 21 CFR 211.42Design and construction featuresIn this theme's rule56
- 21 CFR 211.192Production record review14
- 21 CFR 211.160General requirements8
- 21 CFR 211.22Responsibilities of quality control unit7
- 21 CFR 211.63Equipment design, size, and location7
- 21 CFR 211.100Written procedures; deviations7
- 21 CFR 211.28Personnel responsibilities6
- 21 CFR 211.67Equipment cleaning and maintenance6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
Ask FDAgent about aseptic processing in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.