Farmakeio Outsourcing LLC
Southlake, TX, United States
FEI 3014982757
FDA has 3 inspections on file for Farmakeio Outsourcing LLC in Southlake, TX (FEI 3014982757), from 2019 to 2025. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Jun 10, 2022. FDA issued a warning letter on (CDER · Office of Pharmaceutical Quality Operations, Division II). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 3, 2019–2025
- 2 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Requested under FOIA
- 2 requests, latest Oct 29, 2025
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetOutsourcing FacilityPosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate metal and complaints
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. Your firm failed to adequately investigate and initiate corrective and preventive actions for CAPA #, CAPA-2025-0002 dated 03 Apr 2025, which documents metal shavings being found during Testosterone/Triamcinolone Acetonide granulation resulting from a worn impeller shaft seal and metal fit ring. Your firm failed to identify and or confirm how long the shaft and ring had been worn and or expand the investigation beyond immediately manufactured batches, and into other manufactured finished sterile implantable distributed pellets, e.g., Testosterone Pellet (Product Strengths: 200mg, Lot 3203, Expiry 2/17/202026; 87.5mg, Lot 3193, Expiry 2/17/2026; 62.5mg, Lot 3180, Expiry 2/17/2026; & 50mg, Lot 3179, Expiry 2/17/2026) from Testosterone Granulation [illegible] Expiry 2/17/2026. Additionally, your firm's metal detection system for finished pellets was not operational until May 19, 2025, metal detection performance qualification (PQ) quality unit approval date. Before this date, no finished pellets underwent metal detection as part of its manufacturing process. The [(D)(4)] intermediate product, which is (b)(4) and then processed into pellets, was visually inspected, packaged, [(6)(4)] sterilized, and distributed without this critical check. B. Your firm failed to adequately investigate received customer complaints. For example: 1. COMP-2025-0023 dated 6/20/2025 and COMP-2025-0018 dated 5/23/2025, documents received complaints for cracked pellets. Your firm's failed to adequately investigate the source of cracked pellets within your firm's manufacturing process and expand investigation into all area including distribution. 2. COMP-2025-0002 dated 1/04/2025 - documents received complaint for incorrect pellets distributed. Your customer ordered a [(b)(4)] count packages box of Testosterone/Triamcinolone Pellet (25MG/5MCG), but received Estradiol 25mg pellets. Your firm failed to adequately investigate the product's secondary packaging mix-up.
- Observation 2
Inadequate laboratory specifications/tests
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, A. During a review of your firm's batch record for Product ID#364, Testosterone/Triamcinolone Acetonide Pellet (200mg/40mcg), Lot# 3131, including laboratory test chromatograms, unknown/unidentified peaks were found during sampling testing prior to and following [(b)(4)] - sterilization. Your firm's management reported they are aware of the unknown peaks and at the time of this inspection is working with a contract testing laboratory to identify and determine the pharmacological activity of the foreign peaks for the Testosterone/Triamcinolone Acetonide pellets. Your firm released and distributed this lot and continued producing and distributing more lots of this pellet product without identifying the unknowns. B. Testosterone/Triamcinolone Acetonide Granulation 95%/0.02% Chemical Lot [(b)(4)] Expiry 1/29/2026, Qty. [(b)(4)]; and Lot [(b)(4)] Expiry 2/03/2026, Qty. [(b)(4)] were used to produce Product ID#364, Testosterone/Triamcinolone Acetonide Pellet (200mg/40mcg), Lot#3131. A review of the granulation batch record found your firm failed to establish scientifically sound and appropriate specification for the addition of the API, Triamcinolone Acetonide to the batch in the amount of 0.3g (Specification [(b)(4)]) instead of [(b)(4)] as expected to be in the final formulation of the pellet. This was documented in both granulation batches. This is [(b)(4)] in excess. C. After metal shavings were found in your Testosterone/Triamcinolone Acetonide granulation lots, your firm decided to scan pellets through a metal scanner. However, the sample size of the batch was determined using [(b)(4)] Standard [(b)(4)]: A sample size, ~bX4~ pellets for batch size [(b)(4)] to [(b)(4)] was selected using General Inspection Level III. Your firm failed to comply with USP <790>, which allows AQL, as a sampling requirement at batch release to be conducted "After 100% Manufacturing Inspection."
Show observations 3 to 5
- Observation 3
No dissolution testing for controlled-release
Each batch of controlled-release dosage form drug product is not laboratory tested to determine conformance to the specifications for the rate of release for each active ingredient. Specifically, your firm failed to require or perform dissolution testing on each batch of controlled-release dosage form drug product. The drug product is not laboratory tested to determine conformance to the specifications at a rate of release for each active ingredient that is reproducible. At the time of this FDA inspection, your firm failed to adequately define a dissolution specification for the following pellet product families. A. Testosterone Regular Release Pellet (Contains no Ethylcellulose excipient); Product Strengths: 200mg & 50mg; BUD 365 days. B. Testosterone Pellet (Contains Ethylcellulose excipient); Product Strengths: 200mg, 100mg, 87.5mg, 62.5mg, 50mg, 37.5mg, 25mg, & 12.5mg; BUD 365 days. C. Testosterone/Triamcinolone Acetonide Pellet; Product Strengths: 200mg/40mcg, 100mg/20mcg, 87.5mg/17.5mcg, 62.5mg/12.5 mcg, 50mg/10mcg, 37.5mg/7.5mcg, 25mg/5mcg, & 12.5mg/2.5mcg; BUD 365 days. D. Estradiol Pellet; Product Strengths: 25mg, 20mg, 18mg, 15mg, 12.5mg, 10mg, & 6mg; BUD 365 days.
- Observation 4
Inadequate equipment design and PQ
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and of adequate size to facilitate operations for its intended use. Specifically, A. Your firm's [(b)(4)] Systems, [(6)(4)] Metal detection System qualification failed to show the equipment is adequately designed and sized to facilitate operations for its intended use. During a review of your firm's [(b)(4)], Pharmaceutical Metal Detector Performance Qualification Manual, Approval Date 5/19/2025, the PQ acceptance criteria was found inadequate, and failed to require specifications for the test equipment and materials. For example, within Section 7.2.2, Acceptance Criteria, your firm failed to quantify (based on [(b)(4)]) acceptance and reject allowances for [(b)(4)] and 0[(b)(4)] tablets or test samples. Additionally, in Section 7.2.3, Test Equipment and Materials, your firm failed to quantify how many total samples shall be used for each type (i.e., [(b)(4)], [(b)(4)] and [(b)(4)]) as part of the production equipment qualification. Your firm COO reported a total of [(b)(4)] pellets and 0[(b)(4)] pellet was used in the study for each contaminate pellet type. B. During a review of your firm initiated CAPA-2025-002, Finding foreign material - granulation process, your firm documented the root cause for the origin of the foreign material resulted from the granulator impeller shaft grinding against the [(b)(4)]. A preventive maintenance (PM) was added for the [(b)(4)] - Lab Grinder to include an inspection the [(b)(4)] before running the granulator. Your firm failed to include in the PM an inspection of the impeller shaft and the [(b)(4)] for excessive wear based on investigation findings.
- Observation 5
Calibration and equipment checks inadequate
Routine calibration and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance. Specifically, during a review of your firm's batch record for Testosterone/Triamcinolone Acetonide Pellet 200mg/40mcg, Lot 3468, Expiry 7/23/2026, Sections 2.3.1.3 - 2.3.1.5, document pellets being processed through the [(b)(4)] Systems, [(6)(4)] Metal detection System. Section 2.3.1.5, states [(b)(4)]. Your firm's batch record fail to define and document the type of each sample shall be used, number of control samples, and the frequency during pellet processing to ensure proper performance.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility's drug products are deficient.
- FDCA 503B(a)(10)
Container label, outsourcer facility
The container labels of your outsourcing facility's drug products are deficient.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Show 1 more citation
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Missing "This is a compounded drug" label
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, the statement, "This is a compounded drug," is not on your drug product labels. • Labels for the following drug products do not contain this statement include: DrugName 1ESIOSIB«>NE/1RIAMCINOIONE IESIOSIB«>NE/lRIAMCINOIONE IESIOSIB«>NE/lRIAMCINOIONE IESIOSIB«>NE/TRIAMCINOIDNE 1E510SIB«>NE/1RIAMCINOIDNE IESIOSIB«>NE/lRIAMCINOIDNE IESIOSIB«>NE/lRIAMCINOIDNE 1151USIB«>NE/1RIAMCINOIONE ESJRADIOI. ESJRADIOI. ESJRADIOI. ES1RADIOI. ESJRADIOI. ESJRADIOI. ESlRADIOI. 1E510SIIRONE IESIOSIB«>NE NE 1E510SIIRONE IESIOSIBONE IESIOSHRONE IESIOSIB«>NE IESIOSIBIDNE
- Observation 2
Compounding essentially copies approved drugs
You compound drugs that are essentially a copy 503B(a)(5) and 503B(d)(2). Specifically, a) you approved drugthatis not on the drug shortage list disttibution, and dispensing; or b) are not identical substance that is also a component of an approved drug, and for which there is no change that produces for an individual patient a clinical difference, as determined by the prescribing practitioner, between the drug and the comparable approved drug. Examples of compounded drug products that are essentially a copy • Testosterone Pellets in 12.5 mg, 25 mg, 37.5 mg, 50 mg, 62.5 mg, 87.5 mg, 100 mg, strengths.
Show observation 3
- Observation 3
Aseptic environmental monitoring deficient
Aseptic processing areas are deficient regarding the system of your facility. Specifically, you are not monitoring the environmental conditions for each batch of product you manufacture. Examples of compounded drug product lots that were not environmentally monitored during production: • BR, Lot 176, and BR, Lot 178
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Oct 29, 2025.
Inspection ending Sep 5, 2025Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Oct 29, 2025FDA-FOIA-2025-12425Form 483· 1 of 5 sitesRecords released
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Oct 24, 2024FDA-FOIA-2024-9483Inspection records· 1 of 7 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.137Expiration dating1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Office of Pharmaceutical Quality Operations, Division II · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014982757 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014982757. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.