Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Accurate Rx Pharmacy Consulting, LLC dba Diplomat Specialty I 03 Corporate Lake Drive Infusion GroupInspection ended Jul 15, 2021 · FEI 3013446837 · Observation 1

    Disinfecting agents and cleaning wipes and pads used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, we observed your Pharmacist-in-Charge cleaning your ISO 5 laminar air flow hood on 7/8/2021. A. During these cleaning activities, we observed the use of non-sterile (b) (4) wipes which were used specifically to clean the ISO 5 laminar air flow hood. B. During these cleaning activities, we observed the use of …

    Contains “ISO 5”Read the Form 483 →

  2. Accurate Rx Pharmacy Consulting, LLC dba Diplomat Specialty I 03 Corporate Lake Drive Infusion GroupInspection ended Jul 15, 2021 · FEI 3013446837 · Observation 2

    The ISO 5 classified aseptic processing areas had difficult to clean equipment or surfaces. Specifically, A. During cleaning, you did not clean an approximate [illegible] radius porthole located on the right sidewall of your laminar air flow hood. B. During cleaning, you did not clean all surfaces of the outer packaging of (b) (4) wipes residing in the laminar air flow hood.

    Contains “ISO 5”Read the Form 483 →

  3. Accurate Rx Pharmacy Consulting, LLC dba Diplomat Specialty I 03 Corporate Lake Drive Infusion GroupInspection ended Jul 15, 2021 · FEI 3013446837 · Observation 3

    Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, you did not disinfect your sterile bottle of (b) (4) before transferring from your ISO 7 room into your ISO 5 laminar air flow hood.

    Contains “aseptic*”Read the Form 483 →

  4. Front Door Pharmacy, LLCInspection ended Jun 7, 2021 · FEI 3012937475 · Observation 1

    Personnel were observed conducting aseptic manipulations or placing equipment/supplies in an area that blocked the movement of first pass air around an open unit, whether before or after it is filled with sterile product. Specifically, during the visual sterile production observation of the finished sterile drug product, P105 (b) (4) (PAP30MG/ PHE1MG/ PGE10MCG), Lot # 051321, Expiry 7/16/21 being performed by the pharmacy PIC, the following …

    Contains “aseptic*”Read the Form 483 →

  5. Front Door Pharmacy, LLCInspection ended Jun 7, 2021 · FEI 3012937475 · Observation 2

    Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that prove a challenge to aseptic operations. Specifically, your pharmacy fail to provide an adequate justification for your facility's media fill program in order to simulate aseptic production operations for the worst-case activities and conditions. For example, your firm’s media fill program …

    Contains “media fill*”Read the Form 483 →

  6. Front Door Pharmacy, LLCInspection ended Jun 7, 2021 · FEI 3012937475 · Observation 3

    Environmental monitoring was not performed in your aseptic processing areas. Specifically, Environmental Monitoring and measurement frequency of microbiological contamination (viable/non-viable monitoring) of the air in the ISO 5 zone is inadequate. Your pharmacy fail to establish a viable monitoring program during sterile drug production within the ISO 5 LAFU. Additionally, during a review of your pharmacy's cleanroom re-certification for VIABLE …

    Contains “aseptic*”Read the Form 483 →

  7. Front Door Pharmacy, LLCInspection ended Jun 7, 2021 · FEI 3012937475 · Observation 4

    The use of sporicidal agents in the cleanrooms and ISO 5 classified aseptic processing area was inadequate. Specifically, your firm failed to validate the sporicidal agent, (b) (4) Sporicidal Disinfectant Cleaner for its intended use within the cleanroom and aseptic production processing area. Repeat Observation

    Contains “ISO 5”Read the Form 483 →

  8. Front Door Pharmacy, LLCInspection ended Jun 7, 2021 · FEI 3012937475 · Observation 5

    Your facility design allowed the influx of poor-quality air into a higher classified area. Specifically, your firm air returns are adjacent to your HEPA filters in the ceiling of the ISO (b) (4) 8 Anteroom and ISO 7 Cleanroom used in the production of sterile drugs. Your pharmacy fail to provide records and/or documents (smoke study) in support of adequate air circulation in the prevention of an influx of poor quality air into a higher classified …

    Contains “smoke stud*”Read the Form 483 →

  9. Front Door Pharmacy, LLCInspection ended Jun 7, 2021 · FEI 3012937475 · Observation 7

    ISO-5 classified areas were not certified under dynamic conditions. Specifically, unidirectional airflow was not verified under operational conditions. Your firm’s clean room re-certification reports tests dated 1/27/2021, 8/5/2020, 2/12/2020, and 8/15/2019 were documented as being performed in dynamic conditions. On 5/24/2021, PIC reported no aseptic production simulation was performed at the time of any of the documented cleanroom and ISO 5 …

    Contains “ISO 5”Read the Form 483 →

  10. Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 7

    Microbial (b) (4) hold time study was not adequately conducted. Specifically, a. Purification (b) (4) have a (b) (4) hold time and may be reused for a different process step within expiry. Connection between (b) (4) holding bag and the (b) (4) is not through an aseptic connection and the (b) (4) hold time study did not simulate the reuse condition. b. Fungal (Fusarium oxysporum) contamination was observed from one of the worst-case (b) (4) used …

    Contains “aseptic*”Read the Form 483 →

  11. Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 1

    … Operator (b) (6) was observed on the security camera footage dated (b) (4) wearing protective gowning and foot protection in the controlled not classified hallway outside the (b) (4) room before entering the (b) (4) room through the (b) (4). ii. The deviation investigation did not include a thorough review of personnel movements in and around the facility as a potential source of contamination. iii. The deviation did not include consideration of …

    Contains “gown*”Read the Form 483 →

  12. Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 4

    … Area (b) (4) where bulk drug substance for client (b) (4) and Area (b) (4) where bulk drug substance for client (b) (4) in the same day failing to document de-gowning, showering, and gowning activities according to SOP001516 v 23.0 (effective 2/5/2021) and SOP001516 v 22.0 (effective 9/2/2019). i. According to the security badge access log, security camera footage, and batch record (b) (4) on (b) (4), a manufacturing associate (Operator upstream …

    Contains “gown*”Read the Form 483 →

  13. Emergent Manufacturing Operations Baltimore, LLC.Inspection ended Apr 20, 2021 · FEI 3015448605 · Observation 7

    … substance was taking place, then entered (b) (4) rooms where operations for client (b) (4) bulk drug substance was taking place without properly adhering to gowning procedures. b. Personnel involved in manufacturing operations and engineering entered manufacturing Area (b) while processing of client (b) (4) bulk drug substance was taking place, then entered manufacturing Area (b) (4) while processing for client (b) (4) bulk drug substance was …

    Contains “gown*”Read the Form 483 →

  14. Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 1

    … These batches have been released after concluding that the product sterility was not affected by the microbial excursions. Review of your investigations since 2019 have uncovered multiple instances where the product sterility may have been compromised. For example: (1) Deviation MAY2020012 was opened on May 14, 2020 because operator (b) (6) had a microbial action limit excursion of 1 cfu on her left hand during the sterile filling of Prednisolone …

    Contains “sterili*”Read the Form 483 →

  15. Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 3

    (REPEAT OBSERVATION) Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established: Specifically, A) The media fill performed does not represent the number and complexity of routine and nonroutine interventions that occur during production of commercial sterile injectable products. B) A procedure is not established to determine the number of open vials inside the (b) (4) system to be …

    Contains “purporting to be sterile”Read the Form 483 →

  16. Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 6

    … For example, Return Air ducts in all production rooms including ISO 5, ISO 7, and ISO 8 are not covered during the facility certification process. During inspectional walkthrough on 10/06/2020, return air duct in Room #(b) (4) (ISO 7) was found visibly dirty with unknown residue. The firm was on active shut down from (b) (4), where facility cleaning and certification took place. In addition, there is no established frequency for preventative …

    Contains “ISO 5”Read the Form 483 →

  17. Imprimis NJOF, -LLCInspection ended Jan 29, 2021 · FEI 3013024146 · Observation 7

    … The sample size for sterility was (b) (4) vials and (b) (4) vial was analyzed for endotoxin testing. b) Prednisolone Acetate/Bromfenac ophthalmic drops (1/0.075)%, lot #(b) (4) had a batch size of (b) (4) units released for commercial distribution. The sample size for sterility was (b) (4) bottles and (b) (4) bottle was analyzed for endotoxin testing. c) Dexamethasone/Moxifloxacin intraocular injection (1/5 mg/ml), lot #(b) (4) had a batch size …

    Contains “sterili*”Read the Form 483 →

  18. Lonza Houston, IncInspection ended Dec 10, 2020 · FEI 3013629214 · Observation 4

    OBSERVATION4 Microbial contamination controls are not adequate. Speci On December 8, 2020, we observed manufacturing including [(l5) (4) {15)(.:l~. At the end of the f b) (l operations in the biological safety cabinet aseptic core, operator (b) (4) v2.0 related to microbial monitoring do not give specific instructions for how to collect[

    Contains “biological safety cabinet*”Read the Form 483 →

  19. OSO BioPharmaceuticals Manufacturing, LLCInspection ended Mar 20, 2020 · FEI 1643045 · Observation 1

    … b) Operators reach above shoulder and head level actions which may generate particles bellowing from beneath gowning. Operators were observed reaching above head height (observed 3/16/2020 Filling Line which may generate particles bellowing from beneath gowning. c) Operators were observed sanitizing gloves with sterile operations without pausing for a specific amount Filling Rooms 6ff4 and 6ll4. No contact time has been developed in removing …

    Contains “gown*”Read the Form 483 →

  20. Vital Care of Dickson, LLC.Inspection ended Mar 11, 2020 · FEI 3015826069 · Observation 2

    Failure to conduct media fill studies that closely simulate aseptic processing operations under the worst-case, most-challenging and stressful conditions. Specifically, the firm compounds TPN products which involves several timely aseptic manipulation steps. The current media fills are performed only with a few aseptic manipulation steps.

    Contains “media fill*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.