Skip to content

New Vitalis Pharmacy LLC

4139 Cadillac Ct Ste 201, Louisville, Kentucky, United States

FEI 3014391500

FDA has 3 inspections on file for New Vitalis Pharmacy LLC in Louisville, Kentucky (FEI 3014391500), from 2018 to 2023. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 11 citations from this inspection. They are listed below.

FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations III). No court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: FDCA 501(a)(2)(A).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2018–2023
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
↗
3 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Inadequate smoke studies

      Smoke studies were inadequately performed under dynamic conditions.

    2. FDCA 501(a)(2)(A)

      Failure/inadequate, filter integrity testing

      Failure to conduct post-use filter-integrity testing on filters used to sterilize drug products.

    3. FDCA 501(a)(2)(A)

      Personnel, blocked or disrupted first air

      Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.

    4. FDCA 501(a)(2)(A)

      Media fills, failure

      Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

    5. FDCA 501(a)(2)(A)

      Non-sterile disinfecting agents, ISO 5 area/classified areas

      Use of non-sterile cleaning wipes in the ISO 5 area.

    Show 6 more citations
    1. FDCA 501(a)(2)(A)

      HEPA filters, not sealed

      HEPA filters are not sealed around the perimeter.

    2. FDCA 501(a)(2)(A)

      Personnel infrequently, changed/sanitized gloves

      Personnel infrequently sanitized gloves to prevent contamination.

    3. FDCA 501(a)(2)(A)

      Insufficient use, disinfectant

      Use of a disinfectant in a manner insufficient to achieve adequate levels of disinfection.

    4. FDCA 501(a)(2)(A)

      Use of non-pharmaceutical, ingredients/processing aides

      Use of processing aides not intended for pharmaceutical use in sterile drug production.

    5. FDCA 501(a)(2)(A)

      Sporicidal agent, ISO 5/classified areas

      Use of a sporicidal agent in the facility's ISO 5 areas and classified areas was lacking.

    6. FDCA 501(a)(2)(A)

      Facility design, influx of lesser quality air

      The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      First pass air blockage, open unit with sterile product

      Personnel conducted aseptic manipulations in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.

    2. FDCA 501(a)(2)(A)

      Improper gowning, contamination

      Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.

    3. FDCA 501(a)(2)(A)

      Personnel habits, contamination

      Personnel did not disinfect to prevent contamination.

    4. FDCA 501(a)(2)(A)

      Unsealed HEPA filter, perimeter

      HEPA filters were not sealed around each perimeter to the support frame.

    5. FDCA 501(a)(2)(A)

      Hazardous drugs, prevention of cross-contamination

      You produced hazardous drugs without providing adequate cleaning of utensils to prevent cross-contamination.

    Show 2 more citations
    1. FDCA 501(a)(2)(A)

      Vermin, adjacent area

      Vermin was observed in an area immediately adjacent to your production area.

    2. FDCA 501(a)(2)(A)

      Non-microbial contamination, production area

      Non-microbial contamination was observed in your production area.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Released product quality discrepancy

      Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, Your firm produced finished Testosterone Cypionate 200MG/ML in Grapeseed Oil lots AL-07192018@906 and AL-08072018@901 using apparent food-grade Grapeseed oil supplied by [(b)(4)] [illegible], and labeled by the manufacturer as "Caution: Dietary Supplement." According to your firm's batch record, Your firm produced (b)(4) finished vials of lot AL-07192018@906 using Grapeseed Oil, lot 1801260072. For example, the shipping record shows that a vial of lot AL-07192018@906 was delivered to [illegible] on 08/22/18. Your firm produced (b)(4) finished vials of lot AL-08072018@901 using Grapeseed Oil, lot 1801260072. For example, the shipping record shows that a vial of lot AL-08072018@901 was delivered to [illegible] on 08/29/18.

    2. Observation 2

      Inadequate visual inspection

      Visual inspection of finished drug products prior to distribution is not adequately performed. Specifically, Your firm sterilized Testosterone Cypionate 200 MG/ML in Grapeseed Oil injectable lots AL-07192018@906 and AL-08072018@901 at [illegible] for [illegible] minutes, respectively on 07/24/18 and 08/07/18. Your firm stated that 100% visual checks are performed on each lot prior to labeling and dispensing or distribution to your patient. However, your firm does not utilize any black or white box or additional lighting source to examine for visible particulates, cloudiness, and/or discoloration in the finished vials. For example: Your firm produced [illegible] finished vials from lot AL-07192018@906. Your firm shipped a vial from this lot to [illegible] on 08/22/18. Your firm produced [illegible] finished vials from lot AL-08072018@901. Your firm shipped a vial from this lot to [illegible] on 08/29/18.

    Show observation 3
    1. Observation 3

      Non-sterile wipes in ISO rooms

      Non-sterile, low-shedding wipes are used to clean the ISO 5 hoods. Specifically, On 08/27/18, I observed non-sterile wipes [illegible] in the ISO 7 clean room. Your firm stated that these non-sterile wipes were utilized during the routine cleaning of the ISO 5 hoods.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014391500 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014391500. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.