New Vitalis Pharmacy LLC Form 483, July 2023
FDA issued this Form 483 to New Vitalis Pharmacy LLC in Louisville, Kentucky (FEI 3014391500) at the end of a drug inspection that ended July 5, 2023. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 1, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 5, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Nov 1, 2023
- 119 days after the inspection
FDA's 11 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
- FDCA 501(a)(2)(A)
Inadequate smoke studies
Smoke studies were inadequately performed under dynamic conditions.
- FDCA 501(a)(2)(A)
Failure/inadequate, filter integrity testing
Failure to conduct post-use filter-integrity testing on filters used to sterilize drug products.
- FDCA 501(a)(2)(A)
Personnel, blocked or disrupted first air
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.
- FDCA 501(a)(2)(A)
Media fills, failure
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.
- FDCA 501(a)(2)(A)
Non-sterile disinfecting agents, ISO 5 area/classified areas
Use of non-sterile cleaning wipes in the ISO 5 area.
- FDCA 501(a)(2)(A)
HEPA filters, not sealed
HEPA filters are not sealed around the perimeter.
- FDCA 501(a)(2)(A)
Personnel infrequently, changed/sanitized gloves
Personnel infrequently sanitized gloves to prevent contamination.
- FDCA 501(a)(2)(A)
Insufficient use, disinfectant
Use of a disinfectant in a manner insufficient to achieve adequate levels of disinfection.
- FDCA 501(a)(2)(A)
Use of non-pharmaceutical, ingredients/processing aides
Use of processing aides not intended for pharmaceutical use in sterile drug production.
- FDCA 501(a)(2)(A)
Sporicidal agent, ISO 5/classified areas
Use of a sporicidal agent in the facility's ISO 5 areas and classified areas was lacking.
- FDCA 501(a)(2)(A)
Facility design, influx of lesser quality air
The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3014391500, newest first.
- Form 483, August 2021Inspection ended Aug 27, 2021 · Posted Mar 9, 2022OAI
- Form 483, September 2018Inspection ended Sep 7, 2018 · Posted Apr 30, 2019VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.