FDA has one inspection on file for Assurance Infusion in Houston, Texas (FEI 3015617746). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 10 observations from the PDF; they are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
No endotoxin testing for intrathecal
Your firm does not test any lots of intrathecal drug products for endotoxin prior to release. All lots of intrathecal drug products are produced using non-sterile bulk drugs which are then [illegible] and stored under refrigeration in syringes until use. In addition, your firm assigns a Beyond Use Date of nine days after production for all intrathecal drug products. However, your firm has no data to substantiate the nine day Beyond Use Date. In the last 12 months, your firm produced approximately [illegible] lots of intrathecal drug products which were not tested for endotoxin prior to being dispensed to patients. For example, Hydromorphone 5mg/ml, lot #10302019@35 was produced on 10/30/19 and used in Rx (o) (6) for patient (b)(s.) on the same date.
- Observation 2
Turbidity in sterility samples
On 11/19/2019, I noted turbidity and/or precipitate in the following sterility samples: A. Tri-Mix lot #11112019@9 B. Tri-Mix, lot #11112019@10 C. Tri-Mix, lot #11112019@21 To date, your firm has not performed an investigation.
Show observations 3 to 10
- Observation 3
Operator contaminated aseptic field
On 11/15/19, during the aseptic processing of Morphine 5mg/ml for Injection, lot #11132019@16, an operator was observed placing his gloved hands outside the ISO 5 area to retrieve supplies. Upon re-entry into the ISO 5 hood with the supplies, he failed to re-sanitize his hands. The same operator was observed with the skin of his forehead partially exposed. The operator was observed introducing the exposed skin of his forehead inside the ISO 5 hood.
- Observation 4
ISO 5 not certified dynamically
The ISO 5 classified area was not certified under dynamic conditions. Specifically, smoke studies were not conducted to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions during the last certification.
- Observation 5
No sterility data for 90-day BUD
Your firm does not have sterility testing data to support an assigned BUD of up to 90 days for intrathecal stock solutions. For example, the stock solution for Hydromorphone HCl is assigned a BUD of 90 days after production.
- Observation 6
Disinfectant contact times not specified
SOP # 3.020 entitled, "Cleaning and Maintenance of the Clean Room Facility" (Effective date: 11/9/15) does not identify the contact time used for various disinfectants including [illegible]. In addition, there is no documentation to substantiate the (b) (4) contact time currently in use.
- Observation 7
Depyrogenation process unverified
Your firm uses an [illegible] for the depyrogenation of glassware used in the production of sterile, injectable drug products. The [illegible] used for depyrogenation has never been verified. In addition, a biological indicator has never been used to verify the adequacy of the depyrogenation process.
- Observation 8
Media fills not representative
Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your log sheet for conducting a high risk media fill challenge documents that a total of [illegible] vials (for control and [illegible] for evaluation) will be used to conduct media fills. Review of media fills conducted since 7/18 revealed that the media fills were not representative in that your firm failed to simulate actual production processes. For example, your firm produced Tri-Mix Forte 30mg/2mg/20mcg/ml for Injection, lot #07272019@12 on 7/26/2019 with a batch size of approximately [illegible] vials.
- Observation 9
Non-sterile wipers used in ISO 5
The wipers placed on the work surface inside the ISO 5 hood during production are not sterile. The wipers are used for the placement of [illegible] used in production.
- Observation 10
Integrity tester not calibrated since 2015
Your integrity testing device (Manufacturer: (b) (4) ) has not been calibrated since 2015. The manufacturer's recommendation for re-calibration is annually.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015617746 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015617746. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.