Nanobots Healthcare, LLC dba Assurance Infusion Form 483, December 2019

FDA issued this Form 483 to Nanobots Healthcare, LLC dba Assurance Infusion in Houston, Texas (FEI 3015617746) at the end of a drug inspection that ended December 3, 2019. It lists 10 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Feb 24, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Dec 3, 2019
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Feb 24, 2020
83 days after the inspection
Facility
FEI 3015617746
Houston, Texas

The 10 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    No endotoxin testing for intrathecal

    Your firm does not test any lots of intrathecal drug products for endotoxin prior to release. All lots of intrathecal drug products are produced using non-sterile bulk drugs which are then [illegible] and stored under refrigeration in syringes until use. In addition, your firm assigns a Beyond Use Date of nine days after production for all intrathecal drug products. However, your firm has no data to substantiate the nine day Beyond Use Date. In the last 12 months, your firm produced approximately [illegible] lots of intrathecal drug products which were not tested for endotoxin prior to being dispensed to patients. For example, Hydromorphone 5mg/ml, lot #10302019@35 was produced on 10/30/19 and used in Rx (o) (6) for patient (b)(s.) on the same date.

  2. 2

    Turbidity in sterility samples

    On 11/19/2019, I noted turbidity and/or precipitate in the following sterility samples: A. Tri-Mix lot #11112019@9 B. Tri-Mix, lot #11112019@10 C. Tri-Mix, lot #11112019@21 To date, your firm has not performed an investigation.

  3. 3

    Operator contaminated aseptic field

    On 11/15/19, during the aseptic processing of Morphine 5mg/ml for Injection, lot #11132019@16, an operator was observed placing his gloved hands outside the ISO 5 area to retrieve supplies. Upon re-entry into the ISO 5 hood with the supplies, he failed to re-sanitize his hands. The same operator was observed with the skin of his forehead partially exposed. The operator was observed introducing the exposed skin of his forehead inside the ISO 5 hood.

  4. 4

    ISO 5 not certified dynamically

    The ISO 5 classified area was not certified under dynamic conditions. Specifically, smoke studies were not conducted to demonstrate unidirectional airflow and sweeping action over and away from sterile drug products under dynamic conditions during the last certification.

  5. 5

    No sterility data for 90-day BUD

    Your firm does not have sterility testing data to support an assigned BUD of up to 90 days for intrathecal stock solutions. For example, the stock solution for Hydromorphone HCl is assigned a BUD of 90 days after production.

  6. 6

    Disinfectant contact times not specified

    SOP # 3.020 entitled, "Cleaning and Maintenance of the Clean Room Facility" (Effective date: 11/9/15) does not identify the contact time used for various disinfectants including [illegible]. In addition, there is no documentation to substantiate the (b) (4) contact time currently in use.

  7. 7

    Depyrogenation process unverified

    Your firm uses an [illegible] for the depyrogenation of glassware used in the production of sterile, injectable drug products. The [illegible] used for depyrogenation has never been verified. In addition, a biological indicator has never been used to verify the adequacy of the depyrogenation process.

  8. 8

    Media fills not representative

    Media fills are not performed that closely simulate aseptic production operations, incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations. Specifically, your log sheet for conducting a high risk media fill challenge documents that a total of [illegible] vials (for control and [illegible] for evaluation) will be used to conduct media fills. Review of media fills conducted since 7/18 revealed that the media fills were not representative in that your firm failed to simulate actual production processes. For example, your firm produced Tri-Mix Forte 30mg/2mg/20mcg/ml for Injection, lot #07272019@12 on 7/26/2019 with a batch size of approximately [illegible] vials.

  9. 9

    Non-sterile wipers used in ISO 5

    The wipers placed on the work surface inside the ISO 5 hood during production are not sterile. The wipers are used for the placement of [illegible] used in production.

  10. 10

    Integrity tester not calibrated since 2015

    Your integrity testing device (Manufacturer: (b) (4) ) has not been calibrated since 2015. The manufacturer's recommendation for re-calibration is annually.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterJun 12, 2020CDER · 192 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.