OSRX Inc
Missoula, MT, United States
FEI 3014549846
FDA has 4 inspections on file for OSRX Inc in Missoula, MT (FEI 3014549846), from 2019 to 2025. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Oct 25, 2024. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 4, 2019–2025
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- Requested under FOIA
- 1 request, latest Jan 6, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetOutsourcing FacilityPosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic process controls
PRODUCTION OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, A. Active viable air and non-viable air sampling is not representative of the aseptic filling process. (b)(4) Active viable air is sampled for I I during production of each lot (SOP-CC-0014 Technical Guide Viable Air Sample, page 4 of 12, section 9.6). Procedures do not state (b)(4) when during production it is done. The non-viable air sampler is also ran for I I (b)(4). Filling time during routine production can range from I I. B. Your firm's personal media fills (to qualify personnel) and aseptic process simulations (to qualify the process) do not closely simulate routine production operations. During routine production, personnel can: • Fill or add tips to <bR> droptainers of Atropine Sulfate Monohydrate 0.025% Ophthalmic Solution 3.5 ml, Lot 206446, BUD: 29JUN2026 or • Fill or add septums (stoppers) to (bR> vials of Dexamethasone Phosphate 0.1% + Moxifloxacin Hydrochloride 0.5% Ophthalmic Injection 1 ml, Lot 206594, BUD: 14APR2026. However, during personnel media fills and aseptic process simulations, the operator will sometimes fill less. For example: 1. As part of SOP-CC-0025 Personal Media Qualification, Version 3, Effective Date: (b)(4) 21FEB2025, personnel perform passing personal media fills on (b)(4). Each personal media fill requires them to do line set up and fill no less than <b><> droptainers. They subsequently add the tips/caps within the same media fill. There are no personal media fills performed with vials. II. During aseptic process simulations used for qualifying the process for: • Droptainers (Report ID: MFR-25-0002), production personnel added <bR> tips/caps, but during routine production of Lot 206446, they added <bR-4> tips/caps on droptainers. • Vials (Report ID: MFR-25-001), production personnel <bR> added septums <bR> on (bR) vials, but during routine production of Lot 206594, they added <bR> septums (stoppers) on vials. THIS IS A REPEAT OBSERVATION C. Your firm's smoke studies (performed 25SEP2025) for production of drug products in droptainers is not adequate. For example: 1. At 19:47, the filler appears to be blocking first pass air of (b)(4) column filled, while beginning to fill the (b)(4) column. II. At 20:10, the filler turns the tray to fill the remaining (b)(4) columns. They start with the (b)(4) column then fill the (b)(4) column last. SOP-FIL-0001 Filling Operation section 8.3.16 states to fill the (b)(4) column first, then the (b)(4) column. III. The amount of smoke used and the camera angle are not adequate to see the movement of smoke in critical areas: a. above open droptainers being filled b. above filled droptainers when they are adding tips/caps THIS IS A REPEAT OBSERVATION D. Disinfectant efficacy studies have not been performed for the disinfectant (b)(4) used to wipe (b)(4) and disposables that are wiped down in the ISO[illegible] and ISO[illegible] cleanrooms.
- Observation 2
Inadequate complaint and OOS investigations
QUALITY OBSERVATION 2 Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, Your firm's complaint system is not adequate. Complaints regarding quality do not always lead to an investigation, investigations or outcomes are not always documented and investigations are not always adequate. For example: A. On 24FEB2025, your pharmacist received a report (b)(4) from a patient regarding drug product Prednisolone Phosphate 1% + Moxifloxacin 0.5% + Bromfenac 0.075% Ophthalmic Solution 8 ml, Lot 105095, BUD: 15JUN2025. The patient stated that the product caused a burning sensation in the eye for at least five minutes each time they used it (3 times total). This was not forwarded to quality assurance based on the pharmacist's discretion. No investigation was documented. B. On 09JUL2025, your pharmacist received a report (b)(4) from a patient regarding drug product Prednisolone Phosphate 1% + Bromfenac 0.075% Ophthalmic Solution 5 ml, Lot 205126, BUD: 10JAN2026. The patient stated that she found a very tiny floating thing (orangish/yellowish) after she used the eye drops. The medication incident form indicated that this report was forwarded to quality assurance, but quality assurance did not receive it. C. Investigation of complaints is not adequate. The form received the following complaints: Date Name, active ingredients, Package Lot Qty Quality Event# Complaint Date Made BUD Reported strength Size ml Number Units Prednisolone Phosphate eyelid 1% + Moxifloxacin 0.5% + (b)(4) QE-2025-0083 15-Oct-25 8 206063 8/21/2025 2/17/2026 swelling Bromfenac 0.075% Prednisolone Phosphate eyelid 1% + Moxifloxacin 0.5% + 5 206033 8/15/2025 2/11/2026 (b)(4) QE-2025-0075 13-Oct-25 swelling Bromfenac 0.075% Prednisolone Phosphate eyelid (b)(4) QE-2025-0075 13-Oct-25 1% + Moxifloxacin 0.5% + 5 205980 8/8/2025 2/4/2026 swelling Bromfenac 0.075% A third-party lab performed assay testing on sample retains for lots 206063, 206033 and 205980. In addition, pH and appearance were tested. However, there was no documentation of sterility testing performed. B. Out Of Specification (OOS) investigations do not always identify a root cause, when they do not move forward to a phase 2 investigation. For example: On 11SEP2025, OOS-2025-008 was initiated for a low assay result of (b)(4) in drug product Prednisolone Phosphate 1% + Bromfenac 0.075% Ophthalmic Solution 5 ml, item code 5055, Lot 206150, BUD: 26MAY2026. Retesting was performed, but no root cause was identified. This product was released for dispensing on 05NOV2025.
Show observations 3 to 4
- Observation 3
Unestablished reproducibility and ID methods
LABORATORY OBSERVATION 3 The reproducibility of test methods have not been established. Specifically, Your firm uses (b)(4) test method, for sterility testing release of finished drugs. However, there is no established procedure to identify organisms to the species in the event of a sterility failure.
- Observation 4
Insufficient computer/audit trail controls
OBSERVATION 4 Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Audit trail review of your instruments HPLC[illegible] and HPLC[illegible] is not performed for each analytical record prior to release of each drug product. HPLC[illegible] is used to test assay for the analytes Pred-Moxi-Brom(s) and Atropine(s). HPLC[illegible] is used to test (b)(4) and for research and development. For example, Atropine Sulfate Monohydrate 0.025% Ophthalmic Solution 3.5 ml, Lot 206446, BUD: 29JUN2026 was tested on HPLC[illegible] for Atropine(s) and released without audit trail review.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- FDCA 503B(a)(10)(B)
Drug product container, fails to include
The container of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Show 1 more citation
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate laminar airflow smoke studies
OBSERVATION 1 Your firm's current laminar air [illegible] (smoke studies) were not performed under [illegible] allowing aseptic operations that are representative [illegible] compounding practices nor did they simulate all critical unit operations and interventions used in compounding of your sterile drug products. Specifically, Smoke studies conducted by your firm, in May of 2021 simulate the normal operating [illegible] of the sterile ISO 5 Laminar Air Flow Workstation. 1) You did not simulate the entire filling process, including the compounded drug product. 2) You also did not simulate the practice of two operators working together in your filling, capping and sealing operations. The smoke studies were not conducted under dynamic conditions that fully [illegible] production, including priming of the pump used to fill the vials with the ISO 5 Laminar Air Flow Hood.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Inadequate filter, final product sterilization
The filter intended to render final product sterile was not adequate to accomplish sterilization.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jan 6, 2026. It asked for a Form 483.
Inspection ending Nov 14, 2025Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Jan 6, 2026FDA-FOIA-2026-170Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.167Special testing requirements1 of 2
- 21 CFR 211.192Production record review1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014549846 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014549846. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.