Skip to content

Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Apollo Care LLCInspection ended Apr 5, 2023 · FEI 3013927023 · Observation 1

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. An 8.000% leak (against a specification of (b) (4)) was found in your ISO 5 laminar airflow hood, number (b) (4), in (b) (4) lab (b) (4), during third party certification activities on 02/02/2023. You stated (b) (4) of the …

    Contains “ISO 5”Read the Form 483 →

  2. Apollo Care LLCInspection ended Apr 5, 2023 · FEI 3013927023 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. As of 03/20/2023, your firm has never performed a media fill using 10 mL syringes. In December 2022, your firm began commercially compounding Ketamine 50 mg per 5 mL (10 mg/mL) in 10 mL syringes and you began distributing them in January 2023. In addition, your recent …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  3. Apollo Care LLCInspection ended Apr 5, 2023 · FEI 3013927023 · Observation 3

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, On 03/10/2023, we observed an employee move a (b) (4) beaker of non-sterile Vancomycin bulk solution from the ISO 7 (b) (4) room into the ISO 5 hood without first wiping down the bottom of the beaker with (b) (4). Your SOP number PRC001.1, Cleanroom Activity and Aseptic Technique, requires supplies to be …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  4. SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. You do not routinely employ the use of sporicidal agent(s) in your Grade filling environments [illegible] various spore forming microbes to include molds and bacillus species over the previous approximate two years. These spore forming recoveries are documented in your open (b)(4) i. …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  5. SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 3

    Deviations from written production and process control procedures are not recorded or justified. Specifically, [illegible] glove. A deviation was only opened 3/19/2023 after discussing this failure with your quality management. Media fill batch (b)(4) was filled during the use of this glove. B. You are not required to perform investigations upon failures regarding visual inspections and (b)(4) retraining efforts as well as gowning failures per …

    Contains “media fill*”Read the Form 483 →

  6. SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 4

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. Procedures are not established and / or followed to manage reconciliation of visual inspection personnel qualification documentation, media fill unit inspection documentation, etc. i. Your visual inspection qualification documentation does not reconcile all vials during operator qualifications. ii. Your media fill …

    Contains “media fill*”Read the Form 483 →

  7. FRUEH VERPACKUNGSTECHNIK AGInspection ended Mar 24, 2023 · FEI 3010363503 · Observation 6

    A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated. Specifically, the sterilization process (as reported in Document VB 15254) for (b)(4) (b)(4) The validation does not demonstrate that the process can consistently produce dry product.

    Contains “sterili*”Read the Form 483 →

  8. Bond Pharmacy dba Advanced Infusion SolutionsInspection ended Jan 30, 2023 · FEI 3017983596 · Observation 1

    Non-depyrogenated tools were used in sterile drug production. Specifically, Your firm uses sterile (b)(4) syringes during aseptic production of your sterile intrathecal injectable drug products however, there is no assurance that the (b)(4) syringes are endotoxin/pyrogen free prior to use in aseptic production. For example: -Lot (b)(4) was used during aseptic production on (b)(4) but sent for endotoxin testing on (b)(4).

    Contains “depyrogen*”Read the Form 483 →

  9. Bond Pharmacy dba Advanced Infusion SolutionsInspection ended Jan 30, 2023 · FEI 3017983596 · Observation 2

    You did not make adequate product evaluation and take remedial action where actionable particle counts were found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, Your firm conducts non-viable monitoring of your ISO5 areas (b)(4) and on July 20, 2022, actionable particle counts were obtained in the ISO5 integrated (b)(4) laminar flow hood during aseptic production of sterile intrathecal …

    Contains “ISO 5”Read the Form 483 →

  10. Bond Pharmacy dba Advanced Infusion SolutionsInspection ended Jan 30, 2023 · FEI 3017983596 · Observation 3

    Poor cleaning practices observed in ISO5 classified areas. Specifically, Your firm's routine cleaning practices are inadequate. For example, on 1/19/2023, poor cleaning practices of (b)(4) located in the ISO5 hoods used to suspend stock solutions during aseptic production were observed by your sterile technicians. I observed your sterile technicians fail to properly disinfect and fully wipe down the underside of the (b)(4).

    Contains “aseptic*”Read the Form 483 →

  11. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 1

    The Personnel behavior and practices in aseptic process area, document number AP-SMC-020, establish the responsibility of the In Process Quality Assurance (IPQA) department, for example, "To verify the practices in aseptic process area as per checklist." This includes to, (b) (4) (b) (4) in aseptic area according to the do's and don'ts checklist" and as confirmed by the Senior General Manager Quality Assurance the visual verification is performed …

    Contains “aseptic*”Read the Form 483 →

  12. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 2

    To perform the requisite aseptic set up operations of the aseptic fill line (b) (4) Parenteral, the production operator accesses the (b) (4) Restricted Access Barrier System ((b) (4) RABS) via the fill equipment access panel [e.g., (b) (4)] that is approximately (b) (4) A production operator was observed having to raise both arms and by turning the entire body sideways was able to enter and exit this specific Grade A area. Due to the size of the …

    Contains “aseptic*”Read the Form 483 →

  13. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 3

    Production operators wear protective eyewear (i.e., goggles) during the aseptic processing of a finished drug product. With the Senior General Manager of Quality Assurance, we observed four production operators wearing goggles during the aseptic processing in the (b) (4) RABS. The goggles were not appropriately worn e.g., there were open spaces observed where the goggle straps are tightened and an open space at the bottom of the goggles such that …

    Contains “aseptic*”Read the Form 483 →

  14. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 4

    … include the following materials i.e., the (b) (4) cart's (b) (4) wheels, the (b) (4) that is used to seal the (b) (4) the (b) (4) that are used in the (b) (4) RABS, the (b) (4) gowning material, and the specific type of (b) (4) used in the study is not known. In addition, a. There is a separate Validation study to evaluate the effectiveness of disinfectant for surfaces (b) (4) (b) (4) document number AP-QCM-MIS-039-00, dated 08 Feb 2020. "The …

    Contains “RABS”Read the Form 483 →

  15. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 5

    The aseptic fill lines in (b) (4) include the use of (b) (4) (b) (4) that assist to diffuse the HEPA filter air into the Grade A (b) (4) of the RABS. The Vice President Sterile Manufacturing & Operations confirmed that the (b) (4) are not cleaned and sanitized.

    Contains “aseptic*”Read the Form 483 →

  16. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 6

    The Rationale for Environmental Monitoring dated 14 April 2015, establishes that "A well-defined comprehensive environmental monitoring program is regarded as an essential part of aseptic processing. A good environmental monitoring program will provide evidence that the facility and its equipment are operating under defined controlled conditions. It will provide information on the effectiveness of applied controls measures such as" for example, …

    Contains “aseptic*”Read the Form 483 →

  17. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 7

    An EM sample is taken from the aseptic fill line (b) (4) (b) (4) the (b) (4) of the access panel is sampled. The EM sampling does not consist of any other area within the confined space of where the production operator was observed raising both arms and turning the entire body sideways to enter and exit this specific Grade A area.

    Contains “aseptic*”Read the Form 483 →

  18. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 9

    The Environment Monitoring Program (b) (4) Aseptic Manufacturing Are (b) (4) dated 21 Mar 2017 describes the intent "is to evaluate the potential risk prominent to aseptic areas" and "to capture the potential viable contaminants in the aseptic areas with respect to, Risk identification and justification for environment monitoring location and frequency" and "To evaluate the existing and additional location to identify the worst and representative …

    Contains “aseptic*”Read the Form 483 →

  19. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 10

    … is adequate." The QRM assessment document is silent with respect to providing language that instructs to observe the classified manufacturing areas and the aseptic processing operations. The lack of observing the aseptic filling process provides a limitation with respect to performing a comprehensive trend analysis of the EM sample locations. The Senior Manager of IPQA confirmed that the QRM assessment consisted of reviewing the 21 Mar 2017 …

    Contains “aseptic*”Read the Form 483 →

  20. Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 11

    The Non-viable particle monitoring is cleanrooms of (b) (4) facility, document number AP-QCM-087 describe the frequency of monitoring the Unidirectional air flow (UAF) Grade A, (b) (4) Grade A clean air stations. However, as confirmed by Senior Manager of IPQA, the NVP monitoring does not include obtaining particle measurements during the aseptic filling process e.g., when production personnel are performing the various manual activities in an …

    Contains “unidirectional*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.