Advanced Infusion Solutions
18451 Dallas Pkwy Ste 125, Dallas, Texas, United States
FEI 3017983596DUNS 082325701
Company: Bond Pharmacy INC · Linked by exact D-U-N-S match (025449445) in FDA registration data
FDA has one inspection on file for Advanced Infusion Solutions in Dallas, Texas (FEI 3017983596). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant, Bond Pharmacy INC (D-U-N-S 025449445), has registered 1 other site.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2023
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Non-depyrogenated syringes used in sterile production
Non-depyrogenated tools were used in sterile drug production. Specifically, Your firm uses sterile (b)(4) syringes during aseptic production of your sterile intrathecal injectable drug products however, there is no assurance that the (b)(4) syringes are endotoxin/pyrogen free prior to use in aseptic production. For example: -Lot (b)(4) was used during aseptic production on (b)(4) but sent for endotoxin testing on (b)(4).
- Observation 2
No evaluation after actionable ISO 5 particle counts
You did not make adequate product evaluation and take remedial action where actionable particle counts were found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, Your firm conducts non-viable monitoring of your ISO5 areas (b)(4) and on July 20, 2022, actionable particle counts were obtained in the ISO5 integrated (b)(4) laminar flow hood during aseptic production of sterile intrathecal injectable drug products. Your firm failed to conduct remedial action and there was no assessment performed whether the drug products produced that day were negatively impacted at time of occurrence.
Show observation 3
- Observation 3
Poor cleaning practices in ISO 5 areas
Poor cleaning practices observed in ISO5 classified areas. Specifically, Your firm's routine cleaning practices are inadequate. For example, on 1/19/2023, poor cleaning practices of (b)(4) located in the ISO5 hoods used to suspend stock solutions during aseptic production were observed by your sterile technicians. I observed your sterile technicians fail to properly disinfect and fully wipe down the underside of the (b)(4).
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Bond Pharmacy INCD-U-N-S 025449445
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Bond Pharmacy INC (D-U-N-S 025449445) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Advanced Infusion Solutions Acquisition, LLCRidgeland, Mississippi · FEI 30118047482 inspections2latestNov 15, 2017NAI1 warning letter, Mar 1, 2017
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3017983596 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3017983596. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.