Skip to content

Bond Pharmacy dba Advanced Infusion Solutions Form 483, January 2023

FDA issued this Form 483 to Bond Pharmacy dba Advanced Infusion Solutions in Dallas, Texas (FEI 3017983596) at the end of a drug inspection that ended January 30, 2023. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Apr 5, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jan 30, 2023
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Apr 5, 2023
65 days after the inspection
Facility
FEI 3017983596
Dallas, Texas

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Non-depyrogenated syringes used in sterile production

    Non-depyrogenated tools were used in sterile drug production. Specifically, Your firm uses sterile (b)(4) syringes during aseptic production of your sterile intrathecal injectable drug products however, there is no assurance that the (b)(4) syringes are endotoxin/pyrogen free prior to use in aseptic production. For example: -Lot (b)(4) was used during aseptic production on (b)(4) but sent for endotoxin testing on (b)(4).

  2. 2

    No evaluation after actionable ISO 5 particle counts

    You did not make adequate product evaluation and take remedial action where actionable particle counts were found to be present in the ISO 5 classified aseptic processing area during aseptic production. Specifically, Your firm conducts non-viable monitoring of your ISO5 areas (b)(4) and on July 20, 2022, actionable particle counts were obtained in the ISO5 integrated (b)(4) laminar flow hood during aseptic production of sterile intrathecal injectable drug products. Your firm failed to conduct remedial action and there was no assessment performed whether the drug products produced that day were negatively impacted at time of occurrence.

  3. 3

    Poor cleaning practices in ISO 5 areas

    Poor cleaning practices observed in ISO5 classified areas. Specifically, Your firm's routine cleaning practices are inadequate. For example, on 1/19/2023, poor cleaning practices of (b)(4) located in the ISO5 hoods used to suspend stock solutions during aseptic production were observed by your sterile technicians. I observed your sterile technicians fail to properly disinfect and fully wipe down the underside of the (b)(4).

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.