Apollo Care LLC Form 483, April 2023

FDA issued this Form 483 to Apollo Care LLC in Columbia, Missouri (FEI 3013927023) at the end of a drug inspection that ended April 5, 2023. It lists 6 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 13, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 5, 2023
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jul 13, 2023
99 days after the inspection
Facility
FEI 3013927023
Columbia, Missouri

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Failure to review unexplained discrepancies and batch failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. An 8.000% leak (against a specification of (b) (4)) was found in your ISO 5 laminar airflow hood, number (b) (4), in (b) (4) lab (b) (4), during third party certification activities on 02/02/2023. You stated (b) (4) of the sterile drug products compounded by your firm are aseptically filled in this hood. You reviewed the certification report on 02/17/2023 and did not open a deviation or investigation to determine the potential impact on the approximately (b) (4) batches of sterile drug products filled in this hood since the last time the HEPA filter passed an integrity test on 06/20/2022. In addition, you do not have any scientific rationale for the (b) (4) HEPA filter repair on the 8% leak. Furthermore, there is no documentation to support the lack of a full recertification of the hood after the patching occurred. Based on your beyond use dates (BUD), approximately (b) (4) batches of these sterile drug products were still within expiry as of 03/20/2023. The sterile drug products potentially impacted by this HEPA filter leak include, but are not limited to, the following: -Fentanyl 500mcg (2mcg/mL) and Ropivacaine HCl 250mg (0.1%) added to 250mL IV bag 0.9% Sodium Chloride Injection (For Epidural Use Only), batch number (b) (4) -Fentanyl 50mcg/mL (2,500mcg Total Dose) 50mL Syringe (Injection for Intravenous Use Only), batch number (b) (4) -Vancomycin 1.5g added to 500mL of 0.9% Sodium Chloride (Injection for Intravenous Use Only), batch number (b) (4) THIS IS A REPEAT OBSERVATION FROM THE 2018 INSPECTION B. The following discrepancies were identified during review of your open investigation, number IR-23-002, in response to finding suspect microbial growth on approximately (b) (4) labels of Fentanyl 500mcg (2mcg/mL) and Ropivacaine HCl 250mg (0.1%) added to 250mL IV bag 0.9% Sodium Chloride Injection (For Epidural Use Only), batch number (b) (4), on 01/24/2023: -You did not perform identification testing on the suspect microbial growth. -You did not perform any enhanced or expanded environmental monitoring in classified or unclassified areas as a result of the suspect microbial growth findings. -You removed the outer (b) (4) bags from the Fentanyl 500mcg (2mcg/mL) and Ropivacaine HCl 250mg (0.1%) added to 250mL IV bag 0.9% Sodium Chloride Injection (For Epidural Use Only) without stability data or an adequate impact assessment to determine the impact on your beyond use dates for this product. Approximately (b) (4) units of this product from batch (b) (4) were observed without outer (b) (4) bags in the (b) (4) storage room on 03/07/2023. -You assumed this was the same microbial contamination as a previous event in July 2022 with no scientific evidence. C. The following discrepancies were identified during review of your closed investigation, number IR-22-004, in response to finding suspect microbial growth on one label on Norepinephrine 8 mg added to 250 mL IV bag of 5% Dextrose Injection, batch number (b) (4), on 07/01/2022: -The IV bag with the suspect microbial growth was wiped down and relabeled for distribution. -The investigation states the suspect microbial growth was identified as Trichoderma harzianum and states this organism is unlikely to cause illness or harmful health implications in humans. -The investigation states future drug products held at room temperature would not be placed in bags but does not assess the impact on the light sensitive drug products. D. The following discrepancies were identified during review of your closed deviation investigation, number D-22-067, into contaminated media plates, lot number (b) (4), received from your media plate supplier, which you initiated on 09/06/2022 and listed the duration of the event as 08/15/2022 to 09/15/2022: -Deviation report number D-22-0

    Shortened here; the PDF has the full text.

  2. 2

    Inadequate aseptic process validation and media fills

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. As of 03/20/2023, your firm has never performed a media fill using 10 mL syringes. In December 2022, your firm began commercially compounding Ketamine 50 mg per 5 mL (10 mg/mL) in 10 mL syringes and you began distributing them in January 2023. In addition, your recent media fill, conducted on 09/06/2022, was only performed using 30 mL syringes. As of 03/20/2023, you stated your firm only distributes 10 mL and 50 mL syringes and you do not commercially compound any drug products in 30 mL syringes. B. The following discrepancies were identified during review of your visual inspection qualification program: -Your employees have never been qualified on visually inspecting syringes. Your firm compounds multiple sterile drug products in syringes, including, but not limited to, Fentanyl 50 mcg/mL in 50 mL syringes for injection and Ketamine 50 mg per 5 mL in 10 mL syringes for injection. -Your employees have never been qualified on visually inspecting and identifying critical defects in IV bags. Your QA Director, JDD, stated the visual inspection qualification (b) (4) do not contain critical defects in IV bags, but instead use (b) (4) with critical defects. Your firm does not compound drug products in (b) (4). In addition, your visual inspection qualification reports do not list defect categories such as minor, major, and critical.

  3. 3

    Aseptic technique procedure not followed

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, On 03/10/2023, we observed an employee move a (b) (4) beaker of non-sterile Vancomycin bulk solution from the ISO 7 (b) (4) room into the ISO 5 hood without first wiping down the bottom of the beaker with (b) (4). Your SOP number PRC001.1, Cleanroom Activity and Aseptic Technique, requires supplies to be disinfected when placed into the direct compounding area in the ISO 5 hood.

  4. 4

    Drug products not protected from light

    Drug products are not stored under appropriate conditions of light so that their identity, strength, quality, and purity are not affected. Specifically, The following drug products are not stored in a manner to protect them from light: -Norepinephrine 4mg added to 250mL of 5% Dextrose (Injection for Intravenous Use Only) - Lot (b) (4) -Norepinephrine 8mg added to 250mL of 5% Dextrose (Injection for Intravenous Use Only) - Lot (b) (4) -Norepinephrine 8mg added to 250mL 0.9% Sodium Chloride (Injection for Intravenous Use Only) - Lot (b) (4) -Fentanyl 500 mcg & Ropivacaine HCl 250 mg added to 250 mL 0.9% Sodium Chloride - lot (b) (4)

  5. 5

    Missing required 503B labeling information

    The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A). Specifically, the following information is not found on your drug product labels: A. The established name of the drug Examples of your drug product labels that do not contain this information: - Ketamine Injection 50 mg per 5 mL (10 mg/mL) Single-Use Syringe B. The storage and handling instruction Examples of drug product label where storage and handling instruction is not included: - Norepinephrine 4 mg added to 250 mL of 5% Dextrose - Norepinephrine 8 mg added to 250 mL of 5% Dextrose - Norepinephrine 8 mg added to 250 mL 0.9% Sodium Chloride

  6. 6

    Missing container labels with required information

    The container of your outsourcing facility's drug products is missing the container label and does not include information required by section 503B(a)(10)(B). Examples of drug products without containers labels: - Fentanyl 50 mcg/mL (2,500 mcg Total) in 50 mL Syringe - Ketamine Injection 50 mg per 5 mL (10 mg/mL), Single-Use Syringe - Phenylephrine HCl Injection 1 mg per 10 mL (100 mcg/mL), Single-Use Syringe - Succinylcholine Cl Injection 100 mg per 5 mL (20 mg/mL), Single-Use Syringe - Vancomycin in various strengths added to 0.9% Sodium Chloride, IV bag - Midazolam 1mg/mL (100mg) 100mL IV Bag - Norepinephrine 4 mg added to 250 mL of 5% Dextrose - Norepinephrine 8 mg added to 250 mL of 5% Dextrose - Norepinephrine 8 mg added to 250 mL 0.9% Sodium Chloride - Fentanyl 500 mcg (2 mcg/mL) and Ropivacaine HCl 250 mg added to 250 mL 0.9% Sodium Chloride Injection IV bag

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3013927023, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.