First Royal Care Co. LLC, dba Red Mountain Compounding Form 483, September 2022
FDA issued this Form 483 to First Royal Care Co. LLC, dba Red Mountain Compounding in Mesa, Arizona (FEI 3015235235) at the end of a drug inspection that ended September 12, 2022. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jan 30, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 12, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jan 30, 2023
- 140 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Unverified ISO-5 airflow certification
OBSERVATION 1: ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions. You never performed any dynamic smoke studies for your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. In addition, on 09/01/22, your Lead Sterile Technician stated (b)(6) sealed the approximate (b)(4) inch circular opening on the back panel of the (b)(4) ISO Class 5 LAFW with (b)(4) when it was installed around April 2022. No studies have been performed to ensure the sealed opening does not leak or disrupt laminar airflow. Since approximately 05/31/22, your firm has produced and dispensed approximately (b)(4) lots of hazardous sterile drug products using this ISO Class 5 LAFW.
- 2
ISO-5 equipment difficult-to-clean surfaces
OBSERVATION 2: The ISO 5 classified equipment has difficult to clean surfaces. Specifically, I observed the back panel of your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. On 09/01/22, your Lead Sterile Technician stated the (b)(6)(b)(4) is used to cover the mounting holes for (b)(6)(b)(4) lamps. ISO class 5 equipment surfaces should be completely smooth and easy to clean.
- 3
Inadequate hazardous drug cleaning/segregation
OBSERVATION 3: Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils and/or personnel to prevent cross-contamination. Specifically, your written procedure titled Cleanroom Equipment Cleaning, SOP: [illegible], version one, dated 03/18/22 does not include a deactivation agent when cleaning equipment and utensils used to produce hazardous sterile drug products. The equipment and utensils are non-dedicated and are used to produce both hazardous and non-hazardous sterile drug products. Since approximately 05/31/22, your firm has produced and dispensed approximately (b)(4) lots of sterile drug products which include approximately (b)(4) lots of hazardous sterile drug products.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3015235235, newest first.
- Form 483, August 2021Inspection ended Aug 11, 2021 · Posted Oct 28, 2021OAI
- Amended Form 483, June 2019Inspection ended Jun 14, 2019 · Posted Jan 27, 2020OAI
- Form 483, June 2019Inspection ended Jun 14, 2019 · Posted Sep 16, 2019OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.