Skip to content

First Royal Care Co. LLC dba Red Mountain Compounding Pharmacy amended Form 483, June 2019

FDA issued this Form 483 to First Royal Care Co. LLC dba Red Mountain Compounding Pharmacy in Mesa, Arizona (FEI 3015235235) at the end of a drug inspection that ended June 14, 2019. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 27, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jun 14, 2019
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 27, 2020
227 days after the inspection
Facility
FEI 3015235235
Mesa, Arizona

FDA's 12 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  2. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

  3. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

  4. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.

  5. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  6. Microbiological testing

    Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

  7. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  8. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

  9. Clothing appropriate for duties performed

    Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

  10. Written procedures fail to include

    Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance and instructions for protection of clean equipment from contamination prior to use.

  11. Accurate reproduction included

    Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.

  12. No written record of investigation

    Written records are not made of investigations into unexplained discrepancies.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterSep 10, 2020CDER · 454 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3015235235, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.