Skip to content

First Royal Care Co. LLC, dba Red Mountain Compounding Pharmacy

6828 E Brown Rd Ste 101, Mesa, Arizona, United States

FEI 3015235235

FDA has 3 inspections on file for First Royal Care Co. LLC, dba Red Mountain Compounding Pharmacy in Mesa, Arizona (FEI 3015235235), from 2019 to 2022. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Aug 11, 2021. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
3, 2019–2022
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
↗
4 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unverified ISO-5 airflow certification

      OBSERVATION 1: ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions. You never performed any dynamic smoke studies for your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. In addition, on 09/01/22, your Lead Sterile Technician stated (b)(6) sealed the approximate (b)(4) inch circular opening on the back panel of the (b)(4) ISO Class 5 LAFW with (b)(4) when it was installed around April 2022. No studies have been performed to ensure the sealed opening does not leak or disrupt laminar airflow. Since approximately 05/31/22, your firm has produced and dispensed approximately (b)(4) lots of hazardous sterile drug products using this ISO Class 5 LAFW.

    2. Observation 2

      ISO-5 equipment difficult-to-clean surfaces

      OBSERVATION 2: The ISO 5 classified equipment has difficult to clean surfaces. Specifically, I observed the back panel of your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. On 09/01/22, your Lead Sterile Technician stated the (b)(6)(b)(4) is used to cover the mounting holes for (b)(6)(b)(4) lamps. ISO class 5 equipment surfaces should be completely smooth and easy to clean.

    Show observation 3
    1. Observation 3

      Inadequate hazardous drug cleaning/segregation

      OBSERVATION 3: Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils and/or personnel to prevent cross-contamination. Specifically, your written procedure titled Cleanroom Equipment Cleaning, SOP: [illegible], version one, dated 03/18/22 does not include a deactivation agent when cleaning equipment and utensils used to produce hazardous sterile drug products. The equipment and utensils are non-dedicated and are used to produce both hazardous and non-hazardous sterile drug products. Since approximately 05/31/22, your firm has produced and dispensed approximately (b)(4) lots of sterile drug products which include approximately (b)(4) lots of hazardous sterile drug products.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 15 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Non-pharmaceutical grade component used

      OBSERVATION 1 The(b)<> intended to render final product sterile was not pharmaceutical grade. Specifically, the [(6) (4)] used to produce finished drug products are not pharmaceutical grade. For example, the following dispensed finished sterile drug products were produced using laboratory grade [(6) (4)]: A) Rx[(o) (6)] S-Dexpanthenol 250MG/ML MDV INJ SOLN, Lot 03172021DH@13, was produced using (6) (4) Part number (o) (4) B) Rx[(D) (6)] S-MIC/B12A 25/50/80MG/ML 1 MG/ML MDV, Lot S06042021JL@12, was produced using (6) (4) Part number (o) (4) C) Rx[(D) (6)] S-Methylcobalamin 10,000MCG/ML MDV INJ, lot S0302021DH@01, was produced using (15) (4) (6) (4) Part number (o) (4)

    2. Observation 2

      Required (6)(4) test not performed

      OBSERVATION 2 (6) -(4) testing to the [(6) -(4)] was not performed. Specifically, your firm does not perform the [(6) (4)] test per the [(6) -(4)] manufacturer's specifications. For example: The batch records for the above sub-compounds indicate 13 psi on the records; however, you stated only (15) (4) was used instead of (6) (4) for the (6) (4) test. Your procedure states an (6) (4) mixture can be used but this changes the specification to at least [illegible] psi for the (6) (4). The above sub-compounds, (6) (4) and (6) (4) were used to produce S-Cyclosporine 0.2% OPTH OINTMENT, lot S07152021DH@01, and S-Tacrolimus 0.03% OPTH IN MCT OIL, lot S06302021JL@08, respectively. No further sterilization steps were performed after producing the above finished ophthalmic drug products and no finished product testing has ever been conducted for these products. B) The specification for the (6) (4), Part number (6) (4) (b) is ] psi in water. Your firm used this type of <>< > for (5) (4), lot (b) (4), and 43 psi was recorded on the batch record. No sterility testing was performed on this lot and it was subsequently used to produce Rx[(6)] S-Myer's Cocktail (250ML), lot S04232021DC@04.

    Show observations 3 to 15
    1. Observation 3

      Sterilization cycle not validated

      OBSERVATION 3 The cycle parameters (temperature, pressure and time) used for (6) (4) of product intended to be sterile are not lethal to heat-resistant microorganisms. Specifically, load mapping studies have never been conducted to qualify the (6) (4) process for the sub compound, (6) (4). For example, this sub-compound is subsequently used to produce finished drug products: a) S-Cyclosporine 0.2% OPTH OINTMENT, lot S07152021DH@01 b) S-Tacrolimus 0.03% OPTH IN MCT OIL, lot S06302021JL@08 No further sterilization steps are performed after producing the above finished ophthalmic drug products and no finished product testing has ever been conducted for these products.

    2. Observation 4

      Inadequate media fill challenge

      OBSERVATION 4 Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills do not include the most challenging process performed. For example, your media fill records indicate filling [(6) (4)] ml vials; however, I reviewed sterile production records that demonstrate more challenging operations such as filling (6) ml vials for S-Ascorbic Acid (NON-CORN) 500MG/ML MDV, lot S03042021DH@09 and/or filling [(6) (4)] mls syringes for S-Glutathione 200MG/3ML (PF) INHALATION, lot S03172021DH@04.

    3. Observation 5

      Insufficient environmental monitoring

      OBSERVATION 5 Lack of adequate routine environmental monitoring. Specifically, environmental monitoring of ISO classified zones for viable (surface and air) microorganisms and non-viable particles is conducted on a [illegible] basis only. Your firm produces sterile drug products on a [illegible] basis and dispenses approximately [illegible] sterile drug products per day.

    4. Observation 6

      Deficient personnel monitoring program

      OBSERVATION 6 Lack of adequate personnel sampling. Specifically, personnel monitoring is conducted using samples taken from the gloved hands of employees following sterile drug production on a [(6) -(4)] basis only. Your firm produces sterile drug products on a [(o) (-4)] basis and dispenses approximately [illegible] sterile drug products per day. In addition, your program for monitoring personnel is deficient in that: A) Monitoring does not include samples taken from the gowns of employees. B) Monitoring only includes samples taken from fingertip(s) and does not include the broader surface of the operators' fingers which are used during sterile vial assembly.

    5. Observation 7

      Finished sterile products not tested

      OBSERVATION 7 (Repeat Observation) Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, your firm produces sterile drug products on a [(o) (-4)] basis and dispenses approximately [illegible] sterile drug products per day. Sterility and pyrogen testing are not routinely conducted on finished sterile drug products. For example, Rx[(6) (6)] S-Sod Citrate 4% INJ SOLN MDV, lot S06182021DC@02 and Rx[(6) (6)] S-Myer's Cocktail (250ML), lot S04232021DC@04.

    6. Observation 8

      No stability testing/BUD justification

      OBSERVATION 8 (Repeat Observation) There is no written testing program designed to assess the stability characteristics of drug products. Specifically, extended beyond-use-date (BUD) was used for a high-risk product without the appropriate stability data or required sterility testing. For example, Rx[(b) (6)] S-Sod Citrate 4% INJ SOLN MDV, lot S06182021DC@02, was labeled with a BUD of approximately 30 days and to store at room temperature.

    7. Observation 9

      Finished product potency not verified

      OBSERVATION 9 (Repeat Observation) Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release. Specifically, potency testing is not routinely conducted on finished drug products prior to release. For example, Rx[(b) (6)] S-Sod Citrate 4% INJ SOLN MDV, lot S06182021DC@02 and Rx[(6) (6)] S-Myer's Cocktail (250ML), lot S04232021DC@04.

    8. Observation 10

      Improper sporicidal use/contact time

      OBSERVATION 10 (Repeat Observation) Sporicidal agents were not adequately used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area. Specifically, the cleaning agent, [(15) (4)] is being used as a sporicidal in the ISO 5 BSC; however, it is not labeled as a sporicidal and the approximate contact time observed on 07/15/21 was [(D)-(4)] before wiping.

    9. Observation 11

      Insufficient disinfectant dwell time

      OBSERVATION 11 Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, I observed the cleaning practices in the firm's classified areas on 07/15/21. During cleaning of the ISO 7 areas, the operator did not allow the appropriate [(6) ("1-)] dwell time for the [(6) ("1-)] cleaning agent before wiping. The operators use this cleaning agent for all classified areas outside of the ISO 5 BSC.

    10. Observation 12

      Inadequate containment/cleaning for hazardous drugs

      OBSERVATION 12 Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, the following conditions were observed on 07/14/21 during the production of H-Fluconazole 40MG/ML OIL SUSPENSION, lot 07142021DLJ@03: 1) There were multiple damaged and discolored [(15) (4)] spatulas that were designated clean. One of the [(5) (4)] spatulas had a glossy unknown material on it. 2) There were multiple glass mortars with dust build-up that were designated clean. 3) The scale used to weigh [(15) ("1-)] had a large crack across the front panel with tape holding it together. The above non-sterile equipment and utensils are used to produce hazardous and non-hazardous drug products such as capsules, ointments, gels, creams, suspensions, solutions, suppositories, troches, and sprays.

    11. Observation 13

      Non-sterile gown components used

      OBSERVATION 13 Personnel engaged in aseptic processing were observed wearing non-sterile gown components. Specifically, on 07/16/21, during sterile production Rx[(15) (6)] S-Acetylcysteine 5% ophthalmic solution, lot S07162021DH@02, the operator donned a non-sterile coverall that was past the expiry date, "EXP: 2020-01", listed on the packaging. The operator's sleeves entered the ISO 5 BSC while producing the sterile drug product.

    12. Observation 14

      Scales not checked to required precision

      OBSERVATION 14 Routine checking of scales used for production is not performed to assure proper performance. Specifically, the [illegible] scales used by your firm to produce hazardous and non-hazardous sterile and non-sterile drug products are not routinely checked for accuracy. Example batches requiring small quantities: a) Rx[illegible] H-BIEST/P4/TEST 1.5/100/2MG TROCHE, lot 07082021DLJ@41, requires a quantity of [illegible] grams. b) Rx[illegible] S-Acetylcysteine 5% OPTHALMIC SOLN, lot S07162021DH@02, requires a quantity of [illegible] grams. The scales are calibrated [illegible] but you do not have suitable weights to verify accuracy down to 0.001 grams before use.

    13. Observation 15

      Non-pharmaceutical grade components used

      OBSERVATION 15 Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. Specifically, Rx[(6) (6)] C-BLT 20/10/6% IN DMSO 10% LIPO, lot 04162021DLJ@07 and Rx[(6)] C-BLT 20/10/10% IN DMSO 10% LIPO, lot 06092021DJ@05 used [(o) (4)] which do not indicate USP/NF standards on respective COAs.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 12 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    3. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    4. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.

    5. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    Show 7 more citations
    1. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    2. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    4. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

    5. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance and instructions for protection of clean equipment from contamination prior to use.

    6. Accurate reproduction included

      Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.

    7. No written record of investigation

      Written records are not made of investigations into unexplained discrepancies.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.

Show all 9

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3015235235 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3015235235. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.