First Royal Care Co. LLC, dba Red Mountain Compounding Pharmacy
6828 E Brown Rd Ste 101, Mesa, Arizona, United States
FEI 3015235235
FDA has 3 inspections on file for First Royal Care Co. LLC, dba Red Mountain Compounding Pharmacy in Mesa, Arizona (FEI 3015235235), from 2019 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Aug 11, 2021. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2019–2022
- 2 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Unverified ISO-5 airflow certification
OBSERVATION 1: ISO-5 classified areas were not certified under dynamic conditions. Specifically, uni-directional airflow was not verified under operational conditions. You never performed any dynamic smoke studies for your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. In addition, on 09/01/22, your Lead Sterile Technician stated (b)(6) sealed the approximate (b)(4) inch circular opening on the back panel of the (b)(4) ISO Class 5 LAFW with (b)(4) when it was installed around April 2022. No studies have been performed to ensure the sealed opening does not leak or disrupt laminar airflow. Since approximately 05/31/22, your firm has produced and dispensed approximately (b)(4) lots of hazardous sterile drug products using this ISO Class 5 LAFW.
- Observation 2
ISO-5 equipment difficult-to-clean surfaces
OBSERVATION 2: The ISO 5 classified equipment has difficult to clean surfaces. Specifically, I observed the back panel of your (b)(4) ISO Class 5 LAFW (laminar airflow workstation), model number (b)(4), serial number (b)(4), which is used to produce all hazardous (hormone) sterile drug products since approximately April 2022. On 09/01/22, your Lead Sterile Technician stated the (b)(6)(b)(4) is used to cover the mounting holes for (b)(6)(b)(4) lamps. ISO class 5 equipment surfaces should be completely smooth and easy to clean.
Show observation 3
- Observation 3
Inadequate hazardous drug cleaning/segregation
OBSERVATION 3: Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils and/or personnel to prevent cross-contamination. Specifically, your written procedure titled Cleanroom Equipment Cleaning, SOP: [illegible], version one, dated 03/18/22 does not include a deactivation agent when cleaning equipment and utensils used to produce hazardous sterile drug products. The equipment and utensils are non-dedicated and are used to produce both hazardous and non-hazardous sterile drug products. Since approximately 05/31/22, your firm has produced and dispensed approximately (b)(4) lots of sterile drug products which include approximately (b)(4) lots of hazardous sterile drug products.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 15 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Non-pharmaceutical grade component used
OBSERVATION 1 The(b)<> intended to render final product sterile was not pharmaceutical grade. Specifically, the [(6) (4)] used to produce finished drug products are not pharmaceutical grade. For example, the following dispensed finished sterile drug products were produced using laboratory grade [(6) (4)]: A) Rx[(o) (6)] S-Dexpanthenol 250MG/ML MDV INJ SOLN, Lot 03172021DH@13, was produced using (6) (4) Part number (o) (4) B) Rx[(D) (6)] S-MIC/B12A 25/50/80MG/ML 1 MG/ML MDV, Lot S06042021JL@12, was produced using (6) (4) Part number (o) (4) C) Rx[(D) (6)] S-Methylcobalamin 10,000MCG/ML MDV INJ, lot S0302021DH@01, was produced using (15) (4) (6) (4) Part number (o) (4)
- Observation 2
Required (6)(4) test not performed
OBSERVATION 2 (6) -(4) testing to the [(6) -(4)] was not performed. Specifically, your firm does not perform the [(6) (4)] test per the [(6) -(4)] manufacturer's specifications. For example: The batch records for the above sub-compounds indicate 13 psi on the records; however, you stated only (15) (4) was used instead of (6) (4) for the (6) (4) test. Your procedure states an (6) (4) mixture can be used but this changes the specification to at least [illegible] psi for the (6) (4). The above sub-compounds, (6) (4) and (6) (4) were used to produce S-Cyclosporine 0.2% OPTH OINTMENT, lot S07152021DH@01, and S-Tacrolimus 0.03% OPTH IN MCT OIL, lot S06302021JL@08, respectively. No further sterilization steps were performed after producing the above finished ophthalmic drug products and no finished product testing has ever been conducted for these products. B) The specification for the (6) (4), Part number (6) (4) (b) is ] psi in water. Your firm used this type of <>< > for (5) (4), lot (b) (4), and 43 psi was recorded on the batch record. No sterility testing was performed on this lot and it was subsequently used to produce Rx[(6)] S-Myer's Cocktail (250ML), lot S04232021DC@04.
Show observations 3 to 15
- Observation 3
Sterilization cycle not validated
OBSERVATION 3 The cycle parameters (temperature, pressure and time) used for (6) (4) of product intended to be sterile are not lethal to heat-resistant microorganisms. Specifically, load mapping studies have never been conducted to qualify the (6) (4) process for the sub compound, (6) (4). For example, this sub-compound is subsequently used to produce finished drug products: a) S-Cyclosporine 0.2% OPTH OINTMENT, lot S07152021DH@01 b) S-Tacrolimus 0.03% OPTH IN MCT OIL, lot S06302021JL@08 No further sterilization steps are performed after producing the above finished ophthalmic drug products and no finished product testing has ever been conducted for these products.
- Observation 4
Inadequate media fill challenge
OBSERVATION 4 Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills do not include the most challenging process performed. For example, your media fill records indicate filling [(6) (4)] ml vials; however, I reviewed sterile production records that demonstrate more challenging operations such as filling (6) ml vials for S-Ascorbic Acid (NON-CORN) 500MG/ML MDV, lot S03042021DH@09 and/or filling [(6) (4)] mls syringes for S-Glutathione 200MG/3ML (PF) INHALATION, lot S03172021DH@04.
- Observation 5
Insufficient environmental monitoring
OBSERVATION 5 Lack of adequate routine environmental monitoring. Specifically, environmental monitoring of ISO classified zones for viable (surface and air) microorganisms and non-viable particles is conducted on a [illegible] basis only. Your firm produces sterile drug products on a [illegible] basis and dispenses approximately [illegible] sterile drug products per day.
- Observation 6
Deficient personnel monitoring program
OBSERVATION 6 Lack of adequate personnel sampling. Specifically, personnel monitoring is conducted using samples taken from the gloved hands of employees following sterile drug production on a [(6) -(4)] basis only. Your firm produces sterile drug products on a [(o) (-4)] basis and dispenses approximately [illegible] sterile drug products per day. In addition, your program for monitoring personnel is deficient in that: A) Monitoring does not include samples taken from the gowns of employees. B) Monitoring only includes samples taken from fingertip(s) and does not include the broader surface of the operators' fingers which are used during sterile vial assembly.
- Observation 7
Finished sterile products not tested
OBSERVATION 7 (Repeat Observation) Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, your firm produces sterile drug products on a [(o) (-4)] basis and dispenses approximately [illegible] sterile drug products per day. Sterility and pyrogen testing are not routinely conducted on finished sterile drug products. For example, Rx[(6) (6)] S-Sod Citrate 4% INJ SOLN MDV, lot S06182021DC@02 and Rx[(6) (6)] S-Myer's Cocktail (250ML), lot S04232021DC@04.
- Observation 8
No stability testing/BUD justification
OBSERVATION 8 (Repeat Observation) There is no written testing program designed to assess the stability characteristics of drug products. Specifically, extended beyond-use-date (BUD) was used for a high-risk product without the appropriate stability data or required sterility testing. For example, Rx[(b) (6)] S-Sod Citrate 4% INJ SOLN MDV, lot S06182021DC@02, was labeled with a BUD of approximately 30 days and to store at room temperature.
- Observation 9
Finished product potency not verified
OBSERVATION 9 (Repeat Observation) Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release. Specifically, potency testing is not routinely conducted on finished drug products prior to release. For example, Rx[(b) (6)] S-Sod Citrate 4% INJ SOLN MDV, lot S06182021DC@02 and Rx[(6) (6)] S-Myer's Cocktail (250ML), lot S04232021DC@04.
- Observation 10
Improper sporicidal use/contact time
OBSERVATION 10 (Repeat Observation) Sporicidal agents were not adequately used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area. Specifically, the cleaning agent, [(15) (4)] is being used as a sporicidal in the ISO 5 BSC; however, it is not labeled as a sporicidal and the approximate contact time observed on 07/15/21 was [(D)-(4)] before wiping.
- Observation 11
Insufficient disinfectant dwell time
OBSERVATION 11 Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, I observed the cleaning practices in the firm's classified areas on 07/15/21. During cleaning of the ISO 7 areas, the operator did not allow the appropriate [(6) ("1-)] dwell time for the [(6) ("1-)] cleaning agent before wiping. The operators use this cleaning agent for all classified areas outside of the ISO 5 BSC.
- Observation 12
Inadequate containment/cleaning for hazardous drugs
OBSERVATION 12 Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination. Specifically, the following conditions were observed on 07/14/21 during the production of H-Fluconazole 40MG/ML OIL SUSPENSION, lot 07142021DLJ@03: 1) There were multiple damaged and discolored [(15) (4)] spatulas that were designated clean. One of the [(5) (4)] spatulas had a glossy unknown material on it. 2) There were multiple glass mortars with dust build-up that were designated clean. 3) The scale used to weigh [(15) ("1-)] had a large crack across the front panel with tape holding it together. The above non-sterile equipment and utensils are used to produce hazardous and non-hazardous drug products such as capsules, ointments, gels, creams, suspensions, solutions, suppositories, troches, and sprays.
- Observation 13
Non-sterile gown components used
OBSERVATION 13 Personnel engaged in aseptic processing were observed wearing non-sterile gown components. Specifically, on 07/16/21, during sterile production Rx[(15) (6)] S-Acetylcysteine 5% ophthalmic solution, lot S07162021DH@02, the operator donned a non-sterile coverall that was past the expiry date, "EXP: 2020-01", listed on the packaging. The operator's sleeves entered the ISO 5 BSC while producing the sterile drug product.
- Observation 14
Scales not checked to required precision
OBSERVATION 14 Routine checking of scales used for production is not performed to assure proper performance. Specifically, the [illegible] scales used by your firm to produce hazardous and non-hazardous sterile and non-sterile drug products are not routinely checked for accuracy. Example batches requiring small quantities: a) Rx[illegible] H-BIEST/P4/TEST 1.5/100/2MG TROCHE, lot 07082021DLJ@41, requires a quantity of [illegible] grams. b) Rx[illegible] S-Acetylcysteine 5% OPTHALMIC SOLN, lot S07162021DH@02, requires a quantity of [illegible] grams. The scales are calibrated [illegible] but you do not have suitable weights to verify accuracy down to 0.001 grams before use.
- Observation 15
Non-pharmaceutical grade components used
OBSERVATION 15 Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. Specifically, Rx[(6) (6)] C-BLT 20/10/6% IN DMSO 10% LIPO, lot 04162021DLJ@07 and Rx[(6)] C-BLT 20/10/10% IN DMSO 10% LIPO, lot 06092021DJ@05 used [(o) (4)] which do not indicate USP/NF standards on respective COAs.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 12 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Show 7 more citations
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include assignment of responsibility, description in sufficient detail of methods, equipment and materials used, description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance and instructions for protection of clean equipment from contamination prior to use.
Accurate reproduction included
Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies.
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.
- 21 CFR 211.28Personnel responsibilities1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.167Special testing requirements1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
Show all 9
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015235235 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015235235. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.