Hikma Pharmaceuticals USA Inc. Form 483, June 2024
FDA issued this Form 483 to Hikma Pharmaceuticals USA Inc. in Cherry Hill, New Jersey (FEI 2220525) at the end of a drug inspection that ended June 12, 2024. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 9, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 12, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 9, 2024
- 27 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate smoke study procedures
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and followed. Specifically, your air visualization "smoke" studies, TestProtCHH15017 Protocol to Perform Smoke Profile in Room 115 and TestProtCHH15372 Protocol to Perform Smoke Study In Room 115 for Machine Adjustments utilized by your firm to qualify your controlled environment revealed deficiencies. For example: A. In your protocol, TestProtCHH15017 operations under dynamic conditions were not included such as but not limited to, the changing of the settle plates [illegible], refilling the [illegible] with stoppers during filling operations and clearing a jam from the [illegible] unit. These are operations that are part of your filling process as observed on 05/29/2024 of the filling of Fentanyl In addition, in the video titled Dynamic 10mcg/250M L lot [illegible] - Machine Filling Statio the "smoke" used to show the operation of the [illegible] filler difficult to fully visualize. B. In your protocols, TestProtCHH15372 and TestProtCHH15017, the length of the studies, and volume of smoke utilized are not sufficient to visualize the flow of air within the filling unit. Further, the camera angles in all the studies do not provide a full view of the unit and the movement of air from the top of the unit to the bottom under dynamic conditions.
- 2
Incomplete method transfer validation
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, your firm's co-validated method transfer, Report CHH15181 Method Transfer Report for SOP CHH15817 (TMD227) Determination of Fentanyl in Fentanyl Citrate in 0.9% Sodium Chloride Injection IV Bags omits established characteristics for conducting a method validation, such as but not limited to, Accuracy and instrument comparability. Your firm also provided Memo: FDA Discussion- Co-Validation of the Analytical Procedure for Fentanyl Citrate Injection Assay, dated June 6, 2024, to support your co-validation. TMD227 Determination of Fentanyl in Fentanyl Citrate in 0.9% Sodium Chloride Injection IV Bags was validated by your contracted testing laboratory on their premises and your co-validation was conducted in your Research and Development laboratory. The rationale to support not including characteristics of a method validation other than precision are not discussed in either document.
- 3
QC investigation documentation lacking
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, your firm did not follow the instructions outlined in your procedure, SOP CHH15028 Manufacturing Investigation Report (MIR) System. According to section 7.4.2.4 of SOP CHH15028, "when performing an investigation, if a review of previous lot data, stability and retain samples, customer complaints, Annual Product Reviews, and other identifiable data is performed, this documentation of reviews should be included in the investigation". However, the documentation of the following deviations QE-021941, QE-018568, and QE-007589 did not include the results and data of the additional samples taken to support the impact and risk assessment of the investigation.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and followed.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.