Skip to content

Sanofi Pasteur Form 483, September 2023

FDA issued this Form 483 to Sanofi Pasteur in Marcy-L'Etoile, France (FEI 3002972083) at the end of a biologics inspection that ended September 29, 2023. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 26, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 29, 2023
Biologics · Vaccines and Allergenic Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 26, 2026
1,123 days after the inspection
Facility
FEI 3002972083
Marcy-L'Etoile, France

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Incomplete CTP bulk manufacturing instructions

    The master production and control records are deficient in that they do not include complete instructions. Specifically, there are no defined (b)(4) time frames and/or instructions for the (b)(4) preparation of the Concentrated Tetanus Protein (CTP) bulk in the Haemophilus b Conjugate Vaccine (Tetanus Toxoid Conjugate) manufacturing process. A. The CTP bulk requires the (b)(4) of the bulk after the [illegible] step in Bldg. (b)(4) (Room (b)(4)). [illegible] the (b)(4) solution and collected into (b)(4) individual (b)(4) into a (b)(4) [illegible] by the technician (b)(4) the (b)(4) container in a (b)(4) [illegible] system is rinsed with a (b)(4) [illegible] process. The CTP bulk is (b)(4) for an unknown specified amount of time under the biosafety cabinet. A bioburden sample is taken at this [illegible] B. The production batch record does not include instructions for the [illegible] C. There is no validated mixing time-frame established for the CTP bulk concentration (b)(4) step to ensure [illegible]

  2. 2

    Incomplete deviation investigations and follow-up

    Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, A. Deviation record MLED22E3775 dated August 1, 2022, documents that two vials of (b)(4) (US Market) [illegible] were observed to contain cellulose particles during visual inspection of retain samples related to a complaint of vial breakage (complaint no. 200255622). This lot had been released and distributed within the US market and was reported to the agency as a Biological Product Deviation Report (BPDR) on 09/15/2022. While reviewing the firm's CAPA investigation report MLED22A2877 pertaining to deviation MLED22E3775, it was observed that no effectiveness check was conducted to verify the effectiveness of the corrective action (updating instruction MLE-1-006038 - clarifying the practice of the cutting of bags within filling line 14) implemented in response to the deviation. B. While reviewing (b)(4) batch number (b)(4) for sterile (b)(4) of Act-Hib (US Market), it was observed that the (b)(4) batch was invalidated due to a reconciliation difference between the quantity of crimped vials (11,997) and the quantity of inspected vials (11,996) prior to being sent for (b)(4). Further review into the investigation of the discrepancy (Deviation MLED21E6490) revealed that the discrepancy was likely the result of a lost vial after the crimping step during transfer to visual inspection. Due to the vial being lost, it could not be incubated and read for [illegible] turbidity resulting in a potential impact to product manufactured on line [illegible] utilized at the time. While reviewing the firm's corrective actions pertaining to the deviation, it was observed that no corrective actions were implemented to prevent reoccurrence of this event.

  3. 3

    Improper storage exposing WFI diluent product

    Drug products are not stored under appropriate conditions so that their identity, strength, quality, and purity are not affected. Specifically, within the packaging warehouse, it was observed that one shrink wrapped pallet consisting of [illegible] boxes (b)(4) for [illegible] of WFI diluent batch (b)(4) were not stored under appropriate conditions to prevent potential contamination of the product. It was observed that [illegible] box lids [illegible] covering the extra WFI diluent finished product (b)(4) were dislodged and not attached to the boxes potentially exposing the (b)(4) to the environment. Additionally, this (b)(4) was observed to be stored below a [illegible] unit located within the storage room. While observing warehousing operations within temperature controlled (2-8C) finished product storage room (b)(4) [illegible] Per the firm's Packaging Production Manager, these doses can be distributed and utilized with any lyophilized product the firm manufactures (US and ROW Markets).

  4. 4

    Missing reference standards in critical assays

    Laboratory controls do not include the establishment of scientifically sound and appropriate standards designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. Specifically, reference standards are not included in analytical sequences to verify (b)(4) control for the following critical test assays. A. SOP: MLE 1-005714, titled, [illegible] is used for the Purified Vi Polysaccharide bulk (Typhoid Vaccine) [illegible] of the Vi Polysaccharide (Typhim Vi Vaccine) manufacturing process to [illegible] processing. These steps are identified as critical processing parameters (CPP) in the manufacturing process. B. SOP: Qu-WIN-0040813, titled, "V16 (b)(4) Use of [illegible]" [illegible] A blank is analyzed at the beginning of [illegible] (b)(4) samples are analyzed. An average of the [illegible] measurement. The (b)(4) is measured at the [illegible] absorbance sample result [illegible] method analysis [illegible] readings are used for the (b)(4) method analysis [illegible] steps during the content final release assay.

  5. 5

    Aseptic technique not followed during sterile operations

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, While observing sterile (b)(4) operations for Imovax Rabies batch X1C16 (US Market) on (b)(4) line within the (b)(4) manufacturing building on September 25, 2023, it was observed that (b)(4) operators [illegible] in Rooms (b)(4) and (b)(4) [illegible] did not utilize aseptic best practices to limit disruption [illegible] It was observed that (b)(4) operators were routinely swaying [illegible] their hands by their sides while walking throughout the supporting area during (b)(4) in a non-deliberate manner. [illegible] observed within the [illegible] supporting area on the (b)(4) line (directly outside the (b)(4)) [illegible]

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.