Skip to content

UBI Pharma Inc.

Taiwan

FEI 3004713402DUNS 658871159

FDA has 5 inspections on file for UBI Pharma Inc. in Taiwan (FEI 3004713402), from 2012 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One of the five FOIA requests for this site has asked FDA for this inspection's records.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant is UBI Pharma Inc. (D-U-N-S 658871159).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
5, 2012–2025
0 OAI · 4 VAI · 0 NAI
Inspections with 483 observations shown
2 of 5
Form 483s posted by FDA
↗
Requested under FOIA
5 requests, latest Jan 7, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetDrug Product ManufacturerPosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate equipment design

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its [illegible]. Specifically, the visual inspection of your vials is carried out in [illegible] then undergo Acceptance Quality Limit (AQL) testing before releasing. You (6)(4) R eVI (b)(4) 41 confirmed that the [illegible] was not qualified (6)(4) mcg/mL ~~ mL and ~~ mL vials. The qualification is based on limited number of samples that (6)(4) include (6)(4) defect samples and random samples. Your Production [illegible] did not provide a list of these vials nor was able to produce any documents with respect to the type of defects the samples represented. You also use (b)(4) defect samples to challenge your (6)(4) [illegible]. According to your Production Manager (6)(6), randomly selected defect vials are replaced from the defective vials from the manufacturing. On my request, you completed a daily list of your (6)(4) vials for glass fragments, (6)(4) major defect vials for bad seal. According to your procedure, Maintenance Procedure of [illegible] Batch Manufacturing Record for Batch No. [illegible] (6)(4) mcg/mL ~~ mL and ~~ mL vials include (6)(4) major defect (b)(4). You have used your (6)(4) vials of (b)(4) Injection that are still within the expiry date.

    2. Observation 2

      Insufficient AQL and control procedures

      Control procedures are not established which [illegible] manufacturing processes that may be responsible for causing [illegible] process material and the drug product. Specifically, your procedures SOP No. P3190 [illegible] Procedure of (6)(4) Version 15 Sterile (b)(4) Liquid Vial Inspect; P801 Version 5 Sampling Plan and AQL Calculation (Effective date 3/10 [illegible]) sterile (b)(4) products are essentially free [illegible]. A. E.g., for the [illegible] mL vials, Section (b)(4) provision for 100% [illegible] vial of the batch for a passing specification. This potentially leave at least [illegible]. At this step, you carry out AQL where you inspect (li)(4) [illegible] and do not specify how to collect these (b)(4) vials, nor do you record the location [illegible] AQL. The procedure also does not specify type [illegible]. B. Your procedure SOP No. P3109 Version 15 (Effective date 12/9/2024) does not ensure that defect vials are created in such a way as to demonstrate qualification of the 100% visual inspection test kits. Each test kit is comprised (b)(4) Each vial (including defect vials) is numbered/coded that corresponds to various defects which [illegible]; the procedure did not provide expiration [illegible]. C. Your test kit consists of far exceeding number (li)(4) Inspection of [illegible] Products for Visible Particulates than (b)(4) % of defective units in a test kit. Your procedure also does not have representative pictures for the defects. Your Production [illegible] standards for the defects and stated that the samples are from the corresponding reject types from the manufacturing. D. You qualify your visual inspectors based on 5.3.2 of SOP No. P3109 Version 15 that requires inspectors to [illegible]. On 10/8/2025 upon a reassessment, your operator needed training and requalification. It was also noted that the operator did not set up the (li)(4) [illegible] correctly and measure [illegible] as described in Section [illegible]. The intensity set up was also [illegible]. You recorded at least 15 complaints for [illegible] empty vial, and crack/leak (Table 1). You investigated only three (3) (Batch No. (b)(4) Expiry date (b)(4) date [illegible] (Batch No. [illegible]) and invalidated all these complaints without determining root causes.

    Show observations 3 to 5
    1. Observation 3

      Microbiological contamination controls lacking

      Procedures designed to prevent microbiological contamination are not established and/or followed. Specifically, Protocol PQ/GT2.3.224 Version [illegible] Hood for [illegible] Machine and the Version 02 (Effective date 4/12/2024) provide procedure for performing and evaluating the air flow of [illegible] room [illegible]. Air flow studies performed [illegible]. A. In multiple intervention simulation [illegible] (b)(4) clearly not defined. E.g., Intervention PQ/GT2.3.224 Version 01, Section 4.7.4 pages 20 and 21, the videos were evaluated for "***The Air does not flow from operator to the filling area***" and "The air outside the LFH does not return to the LFH***". Your Production Division Director [illegible] stated that the observations were not relevant and were [illegible] interventions. B. In one of the (6)(4) intervention, Place and take Out Settle Plate (Document No. PQ/GT2.3.224 Version 01, Section 4.7.4 pages 20 and 21), operator was seen to stretch out the hand over the almost entire length of [illegible]. In a similar intervention, Adjust parts' angle/position (PQ/GT2.3.224 Version 02), operator was seen hastily moving hands over the open vials and pushing the vials into the line back onto the (6)(4). Your SOP No. P366 Version 14 Intervention Procedure for Grade A and Grade A Air Supply Area During the Aseptic Filling Process and Operation Procedures for Grade B Area (Effective date 1/15 [illegible]) interrupted/blocked laminar air flow. C. Section 5.1.1.1.1 of your SOP No. P366 Version 14 requires that "before any aseptic operation, both hands to the operator from fingertip to elbows should be disinfected [illegible] disinfectant spray (6)(4)". At least in one (6)(4) or Parts (PQ/GT/2.3.224 Version 02 Filling Section) spraying only the palms of both hands and then contacting the interior [illegible] cleaning the [illegible]. D. Section 5.1.2.3.2 of your SOP No. P366 Version 14 requires that "the hand should not pass over the stoppered containers". However, at least in one take out (b)(4) (PQ/GT/2.3.224 Version 02 Filling Section 2), operator was seen hovering hands over the stoppered vials. A similar behavior was seen on 10/8/2025 during the manufacturing [illegible] 'Remove or straighten stuck vials, breakage'. The operator removed broken/stuck vials leaving [illegible] compromised because of obstruction of first air from the hand movements. The operator was also seen moving hands hastily inside the LFH potentially causing turbulence.

    2. Observation 4

      Quality unit responsibilities incomplete

      The responsibilities and procedures applicable to the quality control unit are not in writing and/or fully followed. Specifically, A. You manufacture (b)(4) injection for your US customer. You do not have a Quality Agreement with your (b)(4). The initial QA was signed on 5/20/2019 and was effective for five years until 5/19/2024. You did not review or renew the QA with [illegible]. B. Your initial QA did not have a provision [illegible]. Section 25.3 of Complaint Handling requires Acknowledgement of receipt and notification within (b)(4) [illegible]. SOP No. P091 Version No. 04 The Procedure for Field Alert Report (US) requires submission of FAR within 3 business days of problem being identified. C. Section 4.2 of SOP No. P091 Version No. 04 requires submission of FAR [illegible] fails to meet the specification established (b)(4) [illegible] g/mL [illegible] injection [illegible]. Underfill vials, empty vials, and at least one complaint (b)(4) decided not to investigate and file FAR. According to your (expired) QA, you are [illegible] responsible for complaint investigation. You did not investigate at least 12 complaints and FAR was not submitted based on the market complaints that suggested that the drug product failed to meet the specification established for it in the application. Table 1. List of market complaints for June 2023 - September 2025 [table largely redacted in the record]. D. You did not follow your procedure SOP No. P034 Version [illegible] (effective date 4/30/2025) and did not create a change [illegible] machine ID# 74.51.00 on Filling Line [illegible]; address Deviation #DR250402 (recorded [illegible]). The CAPA was not effective since a similar deviation DR250504 was recorded on 5/15/2025 for Batch No. [illegible]. You amended the initial CAPA 25020 and [illegible] did not carry out [illegible] to prevent excessive adjustment during the [illegible] or evaluate any product quality impact as a result.

    3. Observation 5

      Insufficient investigation of discrepancies

      There is a failure to thoroughly review any unexplained discrepancy and the failure [illegible] its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, you manufacture [illegible] drug product. You received at least 15 [illegible] crack/leak vial complaints (Table 1). You investigated only 3 (three) (Batch No. (b)(4) Expiry date (b)(4) date [illegible] (Batch No. [illegible]). Section 5.1.2 of SOP No. P818 Version 08 Handling requires, "QA supervisor should acquire the complaint sample(s) from the customer to facilitate the investigation". You do not have any documentary evidence for acquiring the complaint samples. You conducted the investigation without the complaint sample and based on the manufacturing records, invalidated the complaints. Section 5.2.1.1 of SOP No. P818 Version 08 requires checking the complaint sample for counterfeit. It is not clear how you determined that the complaint samples were not counterfeit without acquiring the complaint samples or pictures of the complaint samples. Visual inspection reports for the three implicated batches confirmed presence [illegible] underfill vials: 1 (6)(4) Batch No.1 (6)(4) [illegible]. Your batch record suggested that you sample [illegible] filling rate of [illegible].

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    2. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    4. Cleaning SOPs/instructions

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

    5. Training , Education , Experience overall

      Employees engaged in the manufacture of a drug product lack the training required to perform their assigned functions.

    Show 1 more citation
    1. Laboratory Test Method Verification

      Verification of the suitability of the testing methods is deficient in that they are not documented on the laboratory records.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Jan 7, 2026.

  • Inspection ending Oct 14, 2025Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jan 7, 2026FDA-FOIA-2026-189EIRRecords released
  • Inspection date not given

    4 requests. FDA released records in answer to a request for its Form 483 on Nov 6, 2025. FDAgent holds no copy that FDA posted.

    1. Dec 12, 2025FDA-FOIA-2025-13664Form 483 + EIRRecords released
    2. Nov 24, 2025FDA-FOIA-2025-13202Form 483Closed
    3. Nov 3, 2025FDA-FOIA-2025-12562Form 483Records released
    4. Oct 15, 2025FDA-FOIA-2025-12011Form 483No records found

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 5 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
UBI Pharma Inc.D-U-N-S 658871159

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004713402 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004713402. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.