UBI Pharma Inc. Form 483, October 2025

FDA issued this Form 483 to UBI Pharma Inc. in Taiwan (FEI 3004713402) at the end of an inspection that ran from October 6 to October 14, 2025. It lists 5 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Dec 18, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection
Oct 6–14, 2025
Drug Product Manufacturer
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Dec 18, 2025
65 days after the inspection
Facility
FEI 3004713402
Taiwan

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate equipment design

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its [illegible]. Specifically, the visual inspection of your vials is carried out in [illegible] then undergo Acceptance Quality Limit (AQL) testing before releasing. You (6)(4) R eVI (b)(4) 41 confirmed that the [illegible] was not qualified (6)(4) mcg/mL ~~ mL and ~~ mL vials. The qualification is based on limited number of samples that (6)(4) include (6)(4) defect samples and random samples. Your Production [illegible] did not provide a list of these vials nor was able to produce any documents with respect to the type of defects the samples represented. You also use (b)(4) defect samples to challenge your (6)(4) [illegible]. According to your Production Manager (6)(6), randomly selected defect vials are replaced from the defective vials from the manufacturing. On my request, you completed a daily list of your (6)(4) vials for glass fragments, (6)(4) major defect vials for bad seal. According to your procedure, Maintenance Procedure of [illegible] Batch Manufacturing Record for Batch No. [illegible] (6)(4) mcg/mL ~~ mL and ~~ mL vials include (6)(4) major defect (b)(4). You have used your (6)(4) vials of (b)(4) Injection that are still within the expiry date.

  2. 2

    Insufficient AQL and control procedures

    Control procedures are not established which [illegible] manufacturing processes that may be responsible for causing [illegible] process material and the drug product. Specifically, your procedures SOP No. P3190 [illegible] Procedure of (6)(4) Version 15 Sterile (b)(4) Liquid Vial Inspect; P801 Version 5 Sampling Plan and AQL Calculation (Effective date 3/10 [illegible]) sterile (b)(4) products are essentially free [illegible]. A. E.g., for the [illegible] mL vials, Section (b)(4) provision for 100% [illegible] vial of the batch for a passing specification. This potentially leave at least [illegible]. At this step, you carry out AQL where you inspect (li)(4) [illegible] and do not specify how to collect these (b)(4) vials, nor do you record the location [illegible] AQL. The procedure also does not specify type [illegible]. B. Your procedure SOP No. P3109 Version 15 (Effective date 12/9/2024) does not ensure that defect vials are created in such a way as to demonstrate qualification of the 100% visual inspection test kits. Each test kit is comprised (b)(4) Each vial (including defect vials) is numbered/coded that corresponds to various defects which [illegible]; the procedure did not provide expiration [illegible]. C. Your test kit consists of far exceeding number (li)(4) Inspection of [illegible] Products for Visible Particulates than (b)(4) % of defective units in a test kit. Your procedure also does not have representative pictures for the defects. Your Production [illegible] standards for the defects and stated that the samples are from the corresponding reject types from the manufacturing. D. You qualify your visual inspectors based on 5.3.2 of SOP No. P3109 Version 15 that requires inspectors to [illegible]. On 10/8/2025 upon a reassessment, your operator needed training and requalification. It was also noted that the operator did not set up the (li)(4) [illegible] correctly and measure [illegible] as described in Section [illegible]. The intensity set up was also [illegible]. You recorded at least 15 complaints for [illegible] empty vial, and crack/leak (Table 1). You investigated only three (3) (Batch No. (b)(4) Expiry date (b)(4) date [illegible] (Batch No. [illegible]) and invalidated all these complaints without determining root causes.

  3. 3

    Microbiological contamination controls lacking

    Procedures designed to prevent microbiological contamination are not established and/or followed. Specifically, Protocol PQ/GT2.3.224 Version [illegible] Hood for [illegible] Machine and the Version 02 (Effective date 4/12/2024) provide procedure for performing and evaluating the air flow of [illegible] room [illegible]. Air flow studies performed [illegible]. A. In multiple intervention simulation [illegible] (b)(4) clearly not defined. E.g., Intervention PQ/GT2.3.224 Version 01, Section 4.7.4 pages 20 and 21, the videos were evaluated for "***The Air does not flow from operator to the filling area***" and "The air outside the LFH does not return to the LFH***". Your Production Division Director [illegible] stated that the observations were not relevant and were [illegible] interventions. B. In one of the (6)(4) intervention, Place and take Out Settle Plate (Document No. PQ/GT2.3.224 Version 01, Section 4.7.4 pages 20 and 21), operator was seen to stretch out the hand over the almost entire length of [illegible]. In a similar intervention, Adjust parts' angle/position (PQ/GT2.3.224 Version 02), operator was seen hastily moving hands over the open vials and pushing the vials into the line back onto the (6)(4). Your SOP No. P366 Version 14 Intervention Procedure for Grade A and Grade A Air Supply Area During the Aseptic Filling Process and Operation Procedures for Grade B Area (Effective date 1/15 [illegible]) interrupted/blocked laminar air flow. C. Section 5.1.1.1.1 of your SOP No. P366 Version 14 requires that "before any aseptic operation, both hands to the operator from fingertip to elbows should be disinfected [illegible] disinfectant spray (6)(4)". At least in one (6)(4) or Parts (PQ/GT/2.3.224 Version 02 Filling Section) spraying only the palms of both hands and then contacting the interior [illegible] cleaning the [illegible]. D. Section 5.1.2.3.2 of your SOP No. P366 Version 14 requires that "the hand should not pass over the stoppered containers". However, at least in one take out (b)(4) (PQ/GT/2.3.224 Version 02 Filling Section 2), operator was seen hovering hands over the stoppered vials. A similar behavior was seen on 10/8/2025 during the manufacturing [illegible] 'Remove or straighten stuck vials, breakage'. The operator removed broken/stuck vials leaving [illegible] compromised because of obstruction of first air from the hand movements. The operator was also seen moving hands hastily inside the LFH potentially causing turbulence.

  4. 4

    Quality unit responsibilities incomplete

    The responsibilities and procedures applicable to the quality control unit are not in writing and/or fully followed. Specifically, A. You manufacture (b)(4) injection for your US customer. You do not have a Quality Agreement with your (b)(4). The initial QA was signed on 5/20/2019 and was effective for five years until 5/19/2024. You did not review or renew the QA with [illegible]. B. Your initial QA did not have a provision [illegible]. Section 25.3 of Complaint Handling requires Acknowledgement of receipt and notification within (b)(4) [illegible]. SOP No. P091 Version No. 04 The Procedure for Field Alert Report (US) requires submission of FAR within 3 business days of problem being identified. C. Section 4.2 of SOP No. P091 Version No. 04 requires submission of FAR [illegible] fails to meet the specification established (b)(4) [illegible] g/mL [illegible] injection [illegible]. Underfill vials, empty vials, and at least one complaint (b)(4) decided not to investigate and file FAR. According to your (expired) QA, you are [illegible] responsible for complaint investigation. You did not investigate at least 12 complaints and FAR was not submitted based on the market complaints that suggested that the drug product failed to meet the specification established for it in the application. Table 1. List of market complaints for June 2023 - September 2025 [table largely redacted in the record]. D. You did not follow your procedure SOP No. P034 Version [illegible] (effective date 4/30/2025) and did not create a change [illegible] machine ID# 74.51.00 on Filling Line [illegible]; address Deviation #DR250402 (recorded [illegible]). The CAPA was not effective since a similar deviation DR250504 was recorded on 5/15/2025 for Batch No. [illegible]. You amended the initial CAPA 25020 and [illegible] did not carry out [illegible] to prevent excessive adjustment during the [illegible] or evaluate any product quality impact as a result.

  5. 5

    Insufficient investigation of discrepancies

    There is a failure to thoroughly review any unexplained discrepancy and the failure [illegible] its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, you manufacture [illegible] drug product. You received at least 15 [illegible] crack/leak vial complaints (Table 1). You investigated only 3 (three) (Batch No. (b)(4) Expiry date (b)(4) date [illegible] (Batch No. [illegible]). Section 5.1.2 of SOP No. P818 Version 08 Handling requires, "QA supervisor should acquire the complaint sample(s) from the customer to facilitate the investigation". You do not have any documentary evidence for acquiring the complaint samples. You conducted the investigation without the complaint sample and based on the manufacturing records, invalidated the complaints. Section 5.2.1.1 of SOP No. P818 Version 08 requires checking the complaint sample for counterfeit. It is not clear how you determined that the complaint samples were not counterfeit without acquiring the complaint samples or pictures of the complaint samples. Visual inspection reports for the three implicated batches confirmed presence [illegible] underfill vials: 1 (6)(4) Batch No.1 (6)(4) [illegible]. Your batch record suggested that you sample [illegible] filling rate of [illegible].

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.