Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Indoco Remedies LimitedInspection ended Sep 4, 2016 · FEI 3005124189 · Observation 4

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically. a. Validation of the limits of usage, washing, and sterilization cycles for gowning used in production of sterile © ®and injectable products has not been adequately performed. This encompasses the hood, goggles, boiler suit (one piece suit), and booties worn by operators. The supplier of …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  2. Indoco Remedies LimitedInspection ended Sep 4, 2016 · FEI 3005124189 · Observation 5

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance. Specifically. a. The vial washer that will be used for injectable products filled on Line has surrounding ®® that keep the outfeed for washed vials under Grade A laminar air flow, and is surrounded by a Grade D area. The space is …

    Contains “Grade A”Read the Form 483 →

  3. Cipla LimitedInspection ended Aug 30, 2016 · FEI 3004081307 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed. Specifically, items that are not easily cleanable or sanitizable were observed in aseptic processing and support areas during a walkthrough of Unit {gon 08/24/2016. For example: a. On Lines) an HMI panel operating the filling line, which is located in the Grade B area where operators are working, had an ordinary …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  4. Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 1

    … b) Laboratory media used for sterility testing is not labeled following SOP # QCD/014, titled, “Media Preparation” which states under storage of prepared media, that each media tube is to be stored with the media identification name, lot number and date. However, media is not identified using lot #, name, or date made or expiring. Several racks of test tubes containing media for and used in sterility testing were observed sitting in the …

    Contains “sterili*”Read the Form 483 →

  5. Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 3

    OBSERVATION 3 The use of apparatus not meeting established specifications was observed. Specifically, the ™* used during sterility testing has not been qualified for that purpose.

    Contains “sterili*”Read the Form 483 →

  6. Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 4

    PRODUCTION SYSTEM OBSERVATION 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, a) SOP PRD/004 Clean Room Entry - Exit Procedure requires use of sterile garments prior to entry into the clean room area. However, you have not validated the number of cleaning and sterilization cycles through which the garments can be processed and are …

    Contains “purporting to be sterile”Read the Form 483 →

  7. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 1

    1: Procedures designed to prevent microbiological contamination established, written, and followed. *Repeated Observations from the previous Form FDA-483 Specifically: A. Media fills performed to qualify pharmacists is inadequate in that it did not closely simulate current processes encountered during preparation of drug products as per SOP No. 7. Upon review of media fill documentation the following deficiencies were found: a) None of the …

    Contains “media fill*”Read the Form 483 →

  8. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 2

    2; Procedures designed to prevent microbiological contamination include validation of the sterilization process. Specifically, a) Your firm's [process] used to sterilize Testosterone products has not been validated. (b)(4) (b)(4) are intended to [illegible]. b) (b)(4) are intended to [illegible]. c) Your firm's lyophilization (b)(4) performed in the (b)(4) Methylcobalamin and JGF has not been validated. This [illegible] and (b)(4) *Repeated …

    Contains “sterili*”Read the Form 483 →

  9. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 3

    3. Aseptic processing areas are deficient regarding the system for monitoring environmental conditions; cleaning and disinfecting the room and equipment to produce aseptic conditions. *Repeated Observations from the previous Form FDA-483 issued 11/19/14 and Warning Letter issued 4/27/15. Specifically, Upon observation of cleaning activities prior to sterile operations for Cyanocobalamin performed by aseptic pharmacist (b)(4) I noted the following …

    Contains “aseptic*”Read the Form 483 →

  10. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 4

    4. Aseptic processing areas are deficient regarding air supply filters under positive pressure. Specifically, the latest ISO 5 hood completed on 1 (b)(4) by a contractor do[es] [illegible] under static or dynamic conditions with maximum number [illegible]. It was stated that the smoke study performed in the (b)(4) failed to conduct a smoke study in the ISO 5 buffer room to illustrate [illegible] from the ISO 5 Hood to the L (b)(4). *Repeated …

    Contains “aseptic*”Read the Form 483 →

  11. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 5

    … c) Your firm generated a Quality Related Event Report Form (no SOP in place regarding this form) for a sterility failure for Testosterone Cypionate 210 mg/mL multidose [illegible]. No investigation was conducted by the firm or the control [testing] lab (CTL). Re-training of the pharmacist. This batch was rejected according [illegible] to the batch record. d) Your firm generated a Quality Related Event Report Form for an endotoxin failure for …

    Contains “sterili*”Read the Form 483 →

  12. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 6

    … [illegible] distribution and it is unclear if the two vials containing [illegible] In addition, the batch record does not state that a (b)(4) sterilization. b) During the current FDA inspection, I reviewed the vials, lot # A2516MCPL. I observed that there was no [illegible] using an (b)(4). Also, non-viable air [illegible]. The batch of approximately [illegible] vials (# of vials released was [illegible]) released by your Pharmacist in Charge on …

    Contains “sterili*”Read the Form 483 →

  13. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 7

    7. There are no written standards or specifications, methods of sterilization, and methods of processing to remove pyrogenic properties. Specifically, a) The (b)(4) depyrogenation (b)(4) has not been adequately validated as the firm failed [illegible]. This process is used for all laboratory glassware (i.e. glass vials) used [illegible] products. b) The (b)(4) sterilization (b)(4) have not been adequately validated as the firm failed to …

    Contains “sterili*”Read the Form 483 →

  14. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 8

    8. For each batch of drug product purporting to be sterile and/or [illegible] testing to determine conformance to such requirements. *Repeated Observations from the previous Form FDA-483 issued 11/19/14 and Warning Letter issued 4/27/15. Specifically, A. Testing and release of drug product for distribution do not include appropriate laboratory determination satisfactory conformance to the final specifications and identity and strength prior to …

    Contains “purporting to be sterile”Read the Form 483 →

  15. Absolute Pharmacy LLCInspection ended Apr 11, 2016 · FEI 3011116100 · Observation 9

    9. Results of stability testing are not used in determining expiration dates. Specifically, your firm lacked valid analytical and sterility data to support the following expiration dates applied to your sterile drug products: a) 6-month expiration date assigned to HCG 11,000 IU. b) 3-month expiration date assigned to MIC+B1+B12 25/25/25 mg/mL + 25 mcg/mL. c) 3-month expiration date assigned to Lysine HCL 200 mg injectable. d) 3-month expiration …

    Contains “sterili*”Read the Form 483 →

  16. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A. For the following four out of four products I reviewed, (b)(4) are used for the sterilization for the following drug products labeled as sterile: 1. Methylcobalamin (1 mg/mL) 2. Human Chorionic Gonadotropin (HCG) (3500 IU/vial and 5000 IU/vial) 3. Testosterone Cypionate …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  17. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Specifically, A. I observed the following aseptic deficiencies during the preparation of sterile drug products: 1. Personnel are not sanitizing items (e.g., bags containing vials, syringes, and glassware) prior to placing them into the laminar flow hood (ISO 5). 2. Personnel are placing their head …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  18. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Air (viable and non-viable) sampling within all classified areas is not performed during daily [illegible]. Personnel stated that sampling is only performed every [illegible]. B. There is no continuous or at least periodically monitoring of air pressure differentials during production from the ISO 7 room containing the ISO 5 hoods …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  19. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 4

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. Personnel use non-sterile disinfectants (e.g., (b)(4)) to clean the laminar flow hoods where sterile drug products are prepared. B. No sporicidal agent is used to clean your classified areas, including the laminar flow hood where sterile drug products are prepared. C. No documentation was …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  20. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 5

    Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, I observed inconsistent and inadequate gowning practices during this inspection as described below: A. Gowning qualifications have not been conducted for your pharmacy personnel that prepare drug products in your ISO 7 room under the laminar flow hoods (ISO 5). B. The following non-sterile gowning components are used while preparing sterile drug …

    Contains “gown*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.