Aseptic processing and sterility assurance in FDA Form 483 observations

Keeping sterile drugs sterile: aseptic technique, media fills, ISO 5 air and smoke studies, gowning, sterilization and sterility testing. FDAgent finds 620 such observations in 180 Form 483s issued to 164 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
620
Each quoted below
Form 483s
180
Posted by FDA
Facilities
164
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 169 in 2026

Aseptic processing observations in Form 483s by inspection year
YearObservations
20083
20090
20100
20110
20123
20131
201415
201515
201627
201741
201857
201974
20207
202153
202254
202337
202420
202544
2026169

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.113(b)21 CFR 211.42(c)(10)21 CFR 211.167(a)

The same entries the aseptic processing topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“aseptic*” · “sterili*” · “purporting to be sterile” · “sterile filtration” · “media fill*” · “ISO 5” · “smoke stud*” · “unidirectional*” · “first air” · “gown*” · “laminar*” · “LAF*” · “biological safety cabinet*” · “RABS” · “isolator*” · “depyrogen*” · “container closure integrity” · “critical zone*” · “Grade A”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 620 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 6

    Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, A. Your firm has not validated sterility testing to ensure substances in your product formulations do not interfere with the test and if they can detect low levels of organisms. In addition growth promotion testing is not conducted for media used for sterility testing in-house. B. Your firm has never performed …

    Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →

  2. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 7

    Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, A. No documentation (potency and sterility data) could be provided to support your labeled beyond use date for the sterile drug products that I reviewed: Drug product BUD (days) Methylcobalamin (1 mg/mL) 90 Human Chorionic Gonadotropin (HCG) (3500 …

    Contains “sterili*”Read the Form 483 →

  3. Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 9

    Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use. Specifically, A. Your firm's practice of (b)(4) lab glassware, vials and stoppers with non-sterile (b)(4) has not been verified that this process does not leave behind a chemical residue or introduce particles inside these containers and closures. B. Your firm does not …

    Contains “sterili*”Read the Form 483 →

  4. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 1

    OBSERVATION 1 Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. a). Smoke studies were not performed under dynamic conditions to verify that operators, processing equipment or activities of the ISO 5 non-hazardous clean room (aka Clean Room (b)(4)) do not alter or impede the unidirectionality of air from the HEPA filters to the ISO 5 processing stations where drug …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(vi)Read the Form 483 →

  5. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 2

    OBSERVATION 2 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. a). Environmental monitoring for viable air counts in the ISO 5 zones is not performed at least daily during periods of production. The firm only monitors viable air counts (b)(4) and during the (b)(4) cleanroom certification by an outside vendor; lastly on 10/29/14. b). Environmental monitoring for non-viable particulates in the ISO …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  6. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 3

    OBSERVATION 3 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. a). Sporicidal agents are not used to disinfect the ISO 5 surfaces. b). No disinfectant effectiveness studies have been performed to determine if disinfection agents are effective in aseptic processing areas. Disinfectants used (b)(4) are (b)(4) on a (b)(4) basis and (b)(4) which is used …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(v)Read the Form 483 →

  7. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 4

    OBSERVATION 4 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. a). [illegible] are prepared for various products from non-sterile ingredients. These [illegible] can be held for up to (b)( ) days as for Papaverine HCL. Your firm has not conducted any hold time studies to support the stability/sterility over the time periods that [illegible] are …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  8. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 5

    OBSERVATION 5 Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Your firm does not test every sterile drug lot produced for sterility or endotoxins. Sterile drugs produced from non-sterile components are tested for sterility and endotoxins only for batches (b)(4).

    Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →

  9. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 6

    OBSERVATION 6 The separate or defined areas necessary to prevent contamination or mix-ups are deficient. There are no separate facilities, for processing operations, to prevent contamination from the beta-Lactam injectable drug that you process - Ceftazidime syringe. This beta-Lactam powder, which is contained in glass vials, is processed in the same ISO 5 hood as are sterile injectable non beta-Lactam drugs. There is no assurance that a …

    Contains “ISO 5”Read the Form 483 →

  10. Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 7

    OBSERVATION 7 There shall be a written testing program designed to assess the stability characteristics of drug products. The results of such stability testing shall be used in determining appropriate storage conditions and expiration dates. Your firm has not tested for sterility or potency over the assigned Beyond Use Date (BUD) for all of your sterile drug products. For example, your firm has not conducted complete testing to support the BUDs …

    Contains “sterili*”Read the Form 483 →

  11. Specialty Compounding LLC.Inspection ended May 5, 2015 · FEI 3009815000 · Observation 1

    Your firm has failed to establish adequate procedures for conducting appropriate media fill simulations. Specifically, Your most recent media fills dated 4/30/2014 and 10/1/2014 for each of the operators that work in the ISO 5 LAF hoods do not closely simulate planned production. For example, the (b) (4)

    Contains “media fill*”Read the Form 483 →

  12. Specialty Compounding LLC.Inspection ended May 5, 2015 · FEI 3009815000 · Observation 2

    Your firm has not ensured that your facility is suitably designed with respect to the flow of personnel, in-process materials, and finished sterile drugs; the need for room segregation and process separation; and the impact from heating ventilation and air conditioning (HVAC), air pressurization, and unidirectional airflow, to prevent contamination and other hazards to sterile drugs. Specifically, A. The smoke studies performed by your vendor in …

    Contains “unidirectional*”Read the Form 483 →

  13. Specialty Compounding LLC.Inspection ended May 5, 2015 · FEI 3009815000 · Observation 3

    Your firm has failed to establish and implement adequate operational procedures designed to prevent microbiological contamination of drugs purporting to be sterile. Specifically, Your (b) (4) used for the depyrogenation of glassware used in aseptic processing was qualified on 3/24/2015 using the (b) (4) ((b) (4) (b) (4)). The directions for use for the test indicate that the (b) (4) (b) (4). To date, your firm has not determined where the (b) (4) …

    Contains “purporting to be sterile”Read the Form 483 →

  14. Specialty Compounding LLC.Inspection ended May 5, 2015 · FEI 3009815000 · Observation 4

    Your firm has not established adequate written Standard Operating Procedures to ensure proper maintenance of aseptic processing areas and equipment used in those areas. Specifically, Your firm has not established written procedures that describe the cleaning of glassware used in the production of sterile drug products.

    Contains “aseptic*”Read the Form 483 →

  15. Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 1

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, A. On 03/31/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to [illegible] processes used for the production equipment, [illegible] (ID # -) and the [illegible] used in the depyrogenation and sterilization of production glassware and B. On 03/30/2015, your …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

  16. Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 2

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, A. Your firm failed to adequately validate the following sterile and non-sterile drug production areas currently classified by our firm as an ISO7 in the dynamic state: Cleanroom (sterile production room, positive pressure), Cleanroom (chemotherapy room, negative pressure), Anti-room …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iii)Read the Form 483 →

  17. Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 3

    … On 4/1/2015, your firm's Owner/Pharmacist-in-Charge stated all smoke studies were completed in the [illegible] (b)(4) B. On 03/30/2015, we observed your firm's weigh scales in the Powder Room (ISO 7 classified) are environmentally exposed without adequate containment to prevent powder particulate cross-contamination of drug products during admixing. C. Your firm failed to define a written control system for the plastic slatted doors leading into …

    Contains “smoke stud*”Read the Form 483 →

  18. Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 4

    … Your firm fails to require the continuous use of sterile gowning during the production of sterile drug products. For example on 3/30/2015, a sterile gown used by your firm's Pharmacy Technician was observed hanging on the corner of a stainless steel shelving located in the ISO7 Classified Ante-room. Your firm's procedure, Room Cleaning Procedures-Compounding Labs-Sterile & Non Sterile (SOP# 5.005, Implemented date 9/19/14), reports shelving …

    Contains “gown*”Read the Form 483 →

  19. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 1

    Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform. Specifically, The gown worn by the operator performing aseptic manipulations on Sept. 10, 2014 in the ISO 5 laminar flow hood was not sterile and it did not grip and cover the wrists and the V-neck gown did not cover the operator's upper chest.

    Contains “gown*”Read the Form 483 →

  20. Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 2

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, a. The [illegible] sterilization process for Lidocaine 4% injectable and the [illegible] sterilization process for Hydroxyprogesterone caproate injection have not been validated. b. The [illegible] for the [illegible] stoppers used for Hydroxyprogesterone caproate injection …

    Opens with FDA's citation wording for 21 CFR 211.113(b)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about aseptic processing in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.