Cipla Limited Form 483, August 2016

FDA issued this Form 483 to Cipla Limited in Salcette, India (FEI 3004081307) at the end of a drug inspection that ended August 30, 2016. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 29, 2016. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 30, 2016
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 29, 2016
91 days after the inspection
Facility
FEI 3004081307
Salcette, India

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Investigations not extended to other lots

    Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product. Specifically. a. Regarding LL ®I¥S olution, approximately 7 complaints have been received for lot OE exp. ®@ 1 between April 2015 and June 2016, describing empty containers or similar issues. Approximately 9 complaints have been received for this issue across other lots. Investigation has found that the container-closure system was being damaged during the assembly of the ®® and sterile integrity of the containers was compromised, allowing product to evaporate or leak out of the container. Although®® line ®® | is believed to be an appropriate corrective action to eliminate the defect, prevalence and severity of the defect has not been thoroughly investigated, and inspection for the container-closure defect has not yet been assessed throughout an entire filling run. The product has not been filled since January, 2016, but there are approximately 11 lots on the market within expiry, in addition to lot 9 for which the integrity of the sterile barrier may be questionable. (b) (4) (b) (4) b. oe Solution, lot | is failing to meet the specification limit for content of 0 © the 25° | BY6RH stability condition at 18 months. Values were reported at | © @s, = ©, | ©; aq ©@ and the limit is | % to > %. The root cause of the failure is not clear, and the investigation has not expanded to other lots. There are approximately 12 lots on the market within expiry. c. ©@ Tablets, lot EE was found to be out of specification for assay at the 3-month 25 “C/60%RH stability station (stability limit % -| ®®%). This batch was placed on stability due to it having a lower-than-usual assay value at release, of | ®®h%. by other batches were released with similarly low values and not placed on stability. For example, ®@®% (lot ) and @®% (lot ©)" Although the 3-month OOS was initiated recently on 08/01/2016, other lots with low assay values at release were not also investigated.

  2. 2

    Aseptic areas contain non-sanitizable items

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed. Specifically, items that are not easily cleanable or sanitizable were observed in aseptic processing and support areas during a walkthrough of Unit {gon 08/24/2016. For example: a. On Lines) an HMI panel operating the filling line, which is located in the Grade B area where operators are working, had an ordinary computer mouse attached to it. This could be used in the event the sanitizable touch screen is not functioning. The buttons on the mouse may be difficult to clean and sanitize effectively for use in the cleanroom environment. b. On Liney) the batch record was observed being held together with a metal binder clip, being used just outside the filling area. This clip may be difficult to clean and sanitize to ensure that it does not potentially contribute to contamination by operators working in the cleanroom environment. c. On Linef§ a floor balance used for collecting process data had a display panel mounted to the wall, which had a bundle of wires hanging from it. These wires may be difficult to clean and sanitize effectively for use in the cleanroom environment. d. On Line) in the bulk manufacturing area, prior to ®I4,£ product, the room contained both a sanitizable cleanroom phone panel on the wall, as well as a traditional telephone with coiled cord, which ‘may be difficult to clean and sanitize. Raw materials in| ®®form may be handled in this room for bulk ‘manufacture. © RON Cw © @) | Pgducts produced in Unit ial which may be processed on Line fg nclude

  3. 3

    Equipment design does not ensure integrity

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, at the) of each of | “IE ‘machines, the process includes a ®® system, but it is only validated to ®® holes that may occur at the ® of each vial and not thronghont the container itself This is nerformed . (4) © @ (0) (4) following | by which a 2 There is no routine vial integrity testing performed after this. There is no assurance that if a leak were™® in any other part of the ®® container that it would be ®® Products filled on these lines include O@gspension and © ®and ®@g, lution.

  4. 4

    Field Alert Report not timely submitted

    An Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product. Specifically. an| Field Alert Report (FAR) was filed only after 7 complaints for empty container in sterile product pd Solution, lot ®' were received, between April 2015 and June 2016. This product is contract manufactured for ®® who holds the product application. The FAR was not filed until 08/01/2016, approximately 16 months after the first complaint, which is indicative of a breach in the sterile barrier of the product, was received. Additionally, complaints of this nature were also received for lots| | @@ | @@ 1 O@ OF and[O@ py this has not been described in reporting to the Agency.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3004081307, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.