Brookfield Medical Surgical Supplies Inc
Connecticut
FEI 3011430551
FDA has 5 inspections on file for Brookfield Medical Surgical Supplies Inc in Connecticut (FEI 3011430551), from 2015 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Apr 18, 2017. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 5, 2015–2026
- 2 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 5
- 5 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetPosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate OOS potency results
OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your firm failed to adequately investigate Out-of-Specification (OOS) results for sterile drug products manufactured during May 2024-June 2026. A review of thirteen (13) OOS potency failures across multiple drug products and lots, indicates a recurring and systemic failure to maintain adequate process controls. All OOS were reportedly attributed to the contract testing laboratory and resolved via retesting at the same lab. Table below shows all the potency OOS: Deviation Date Type # Initiated DV24-051 September 19, 2024 Potency OOS DV25-053 April 3, 2025 Potency Morphine Sulfate OOS DV25-054 April 7, 2025 Potency Methylprednisolone OOS DV25-055 June 9, 2025 Potency Betamethasone Sodium Phosphate OOS DV25-056 July 3, 2025 Potency Triamcinolone Acetonide OOS DV25-058 September 29, 2025 Potency Betamethasone Sodium Phosphate OOS DV26-059 January 2, 2026 Potency Methylprednisolone Acetate OOS DV26-060 February 9, 2026 Potency Betamethasone Sodium Phosphate OOS DV26-061 February 9, 2026 Potency Betamethasone Sodium Phosphate OOS DV26-062 February 12, 2026 Potency Betamethasone Sodium Phosphate OOS DV26-065 June 5, 2026 Potency Triamcinolone Acetonide OOS DV26-066 June 5, 2026 Potency Triamcinolone Acetonide OOS DV26-067 June 5, 2026 Potency Triamcinolone Acetonide OOS Thirteen (13) OOS potency deviations were recorded over a 26-month period (May 2024-June 2026). OOS potency failures were observed across four (4) distinct sterile drug products - Triamcinolone Acetonide, Betamethasone Sodium Phosphate, Methylprednisolone Acetate, and Morphine Sulfate. Repeated failures were observed with the same product, for example: Betamethasone Sodium Phosphate exhibited four (4) separate OOS potency events (DV25-055, DV25-058, DV26-060, DV26-061, DV26-062), and Triamcinolone Acetonide exhibited four (4) events (DV24-051, DV25-056, DV26-065, DV26-066, DV26-067), suggesting that root cause analyses and corrective and preventive actions (CAPAs) were either inadequate or ineffectively implemented at the contract testing laboratory. For DV25-058 (Betamethasone lot 091225-1), the root cause was undetermined. However, the contract lab did not request a second sample to verify the results when no root cause was identified. Your firm did not conduct further investigation. All the compounded drug products were released for distribution after the initial results were invalidated except Triamcinolone Acetonide 3 mL Lot number 051526-1 which was a confirmed out potency result.
- Observation 2
Inadequate quality control unit oversight
OBSERVATION 2 The responsibilities and procedures applicable to the quality control unit are not fully [followed]. Specifically, Your quality control unit failed to exercise adequate oversight when performing potency testing (refer to the table in Observation 1) as evidenced by: (1) Pattern of OOS invalidation without adequate QCU scrutiny Thirteen (13) Out-of-Specification (OOS) potency results were recorded over 26 months between May 2024 and June 2026 across four drug products (Triamcinolone Acetonide, Betamethasone Sodium Phosphate, Methylprednisolone Acetate, and Morphine Sulfate). Twelve (12) of these OOS results were invalidated and product was released without documented evidence that the quality control unit independently reviewed the contract laboratory's raw data, chromatograms, instrument logs and invalidation rationale. One result (Triamcinolone Acetonide 3 mL, Lot 051526-1) was confirmed and the contract lab's invalidation conclusions in 12 of 13 cases were not independently verified by the QCU. For DV25-058 (Betamethasone lot 091225-1), the contract testing laboratory stated the root cause was undetermined. Your firm released the batch without any assignable cause identified or initiating any CAPA. (2) Failure to question repeated OOS results from the same contract laboratory Betamethasone Sodium Phosphate had 5 separate OOS events (DV25-055, DV25-058, DV26-060, DV26-061, DV26-062) - all tested by the same contract lab, and all apparently invalidated except as noted. QCU did not question the lab's analytical capability after recurring failures with the same product. (4) Rapid closure of deviations without thorough investigation and initiation Several deviations were opened and closed within a short period: DV25-053: opened April 3, closed April 9 (6 days) DV25-054: opened April 7, closed April 14 (7 days) DV26-059: opened January 2, closed January 7 (5 days) DV26-062: opened February 12, closed February 17 (5 days) A 5-7 day turnaround for an OOS potency investigation (including Phase I lab investigation and Phase II manufacturing investigation) is extremely compressed and indicates the QCU accepted results without conducting a thorough independent review. (5) Failure to auditor-qualify the contract laboratory The QCU did not audit the contract testing laboratory during the period in which 13 OOS results were generated.
Show observation 3
- Observation 3
Environmental monitoring excursions not investigated
OBSERVATION 3 Procedures designed to prevent microbiological contamination are not followed. Specifically, The environmental monitoring program of your firm allows for a CFU limit for gloved fingertips in an ISO-5 area. For a COMP compliant 503B facility, the action level must be any detected organism. Furthermore, your firm failed to investigate and identify the microbial growth recovered from the ISO-5 environment at the facility. All the compounded drug products were released for distribution. The environmental monitoring (EM) excursion records below document nine (9) microbial excursions occurring in ISO-5 classified areas between May 8, 2025, and June 24, 2026. Of these, five (5) involved gloved fingertip samples, three (3) involved personnel fingertip samples, and one (1) involved a surface sample. All samples yielded 1 CFU, exceeding the action level established for ISO-5 areas. Only one excursion (No. 39, dated 2026-05-21) which involved a surface sample from location ISO-5 was identified to genus level as Bacillus species. No other microbial excursions from the ISO-5 environment were isolated and identified. Excursions documented: 14 2025-05-08 Fingertip 17 2025-06-18 Fingertip 18 2025-07-18 Fingertip 24 2025-09-25 Fingertip 32 2025-12-23 ISO-5 33 2026-01-14 Fingertip ISO-5 35 2026-02-06 ISO-5 39 2026-05-21 Surface ISO-5 (Bacillus species) 40 2026-06-24 Fingertip ISO-5 Gloved fingertip excursions have a zero-tolerance action level for a 503B facility; any growth after working in ISO-5 areas constitutes an immediate excursion requiring investigation. It also requires genus-level microbial identification when action levels are exceeded. No root cause investigation, corrective action, or re-sampling results were available for these excursions. Bacillus species (Excursion No. 39, 2026-05-21).
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
- FDCA 503B(a)(10)(B)
Drug product container, fails to include
The container of your outsourcing facility's drug products does not include information required by section 503B(a)(10)(B) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Microbiological Contamination Exam
Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.
Show 1 more citation
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions .
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written and followed .
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Show 2 more citations
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed .
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination4 of 4
- 21 CFR 211.42Design and construction features3 of 4
- 21 CFR 211.100Written procedures; deviations3 of 4
- 21 CFR 211.67Equipment cleaning and maintenance2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 4
- 21 CFR 211.111Time limitations on production1 of 4
Show all 9
- 21 CFR 211.186Master production and control records1 of 4
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011430551 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011430551. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.