Quality unit responsibilities in FDA Form 483 observations
The quality control unit's authority and duties: approving or rejecting materials and batches, reviewing records and procedures, and overseeing investigations. FDAgent finds 141 such observations in 103 Form 483s issued to 100 facilities, for inspections that ended between March 2012 and August 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 141
- Each quoted below
- Form 483s
- 103
- Posted by FDA
- Facilities
- 100
- Distinct FEIs
- Most recent
- Aug 12, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 50 in 2026
| Year | Observations |
|---|---|
| 2012 | 1 |
| 2013 | 0 |
| 2014 | 0 |
| 2015 | 1 |
| 2016 | 5 |
| 2017 | 5 |
| 2018 | 4 |
| 2019 | 2 |
| 2020 | 0 |
| 2021 | 3 |
| 2022 | 9 |
| 2023 | 17 |
| 2024 | 12 |
| 2025 | 32 |
| 2026 | 50 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“quality unit*” · “quality control unit*” · “QCU” · “QU” · “quality assurance unit*” · “quality assurance department*” · “QA unit*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 141 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Linhai Tianyu Pharmaceutical Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3013345425 · Observation 3
Written records of investigation into unexplained discrepancies and the failure of a batch or any of its components to meet specification do not always include the conclusions and follow-up. Specifically, Investigations initiated and performed by your Quality Unit in response to Out of Specification results, laboratory events, and market complaints related to intermediates and API manufactured by your firm are not always scientifically sound or …
Contains “quality unit*”Read the Form 483 →
Linhai Tianyu Pharmaceutical Co., Ltd.Inspection ended Sep 15, 2023 · FEI 3013345425 · Observation 7
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, Supervisory oversight over the laboratory electronic systems and data is deficient. Per your firm's data review procedure, Quality Control (QC) personnel perform review electronic test data for all analytical batch records using an approved review procedure and checklist for HPLC/GC network equipment. This review process …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
Wickliffe LLCInspection ended Sep 15, 2023 · FEI 3002992930 · Observation 4
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release. Specifically, Your firm only tests potency of a product the first time it is compounded. Once the first batch is successfully produced for potency then all subsequent batches are not tested for potency. On 5/24/2023, your …
Contains “quality control unit*”Read the Form 483 →
Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 4
Revalidation of equipment used in the processing of drug product is not performed at appropriate intervals. Specifically, A) Your firm's Quality Unit failed to ensure equipment is maintained and used within its validated state. For example: (b) (4) ID 130-(b) (4)-5311: Was due on 01-Jul-2022. However, the equipment was not revalidated until 21-Sep-2022. Your firm produced (b) (4) batches using items that were (b) (4) within this time using this …
Contains “quality unit*”Read the Form 483 →
Samsung Biologics Co. Ltd.Inspection ended Sep 1, 2023 · FEI 3010479596 · Observation 5
The Quality Unit is inadequate to ensure it is capable of carrying out it's roles and responsibilities. For example: A) The Quality Unit has not ensured quality records such as deviations and non-conformance investigations are closed within their respective due dates. Between Quarter 1 2022 and Quarter 2 2023 the average amount of overdue deviation and non-conformance investigations were 10% and 18%, respectively. B) SOP-QC-00105, "Invalid Assay …
Contains “quality unit*”Read the Form 483 →
UCB Farchim SAInspection ended Jul 4, 2023 · FEI 3005023799 · Observation 1
Quality unit oversight over quality control operations is deficient, including laboratory and productions electronic systems and data review. A. During my review of your Empower 3 chromatography software, interrupted sequences were observed, which generated "Data Incomplete" and "Missing Data" chromatographic data. As a result, the interrupted sample injections were not adequately documented to have occurred within your quality control system, …
Contains “quality unit*”Read the Form 483 →
Ipca Laboratories LimitedInspection ended Jun 23, 2023 · FEI 3007574780 · Observation 6
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, the quality unit failed to control the laboratory test methods created and then transferred in LES Development server as per SOP CSOP/2016/047, "Method Creation on Method Builder Software". Computerized system LES (Laboratory Execution System) is used by the quality control laboratory for documentation and to perform analysis. …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
Qilu Antibiotics Pharmaceutical Co., LTD.Inspection ended May 30, 2023 · FEI 3009831352 · Observation 5
The responsibilities and procedure applicable to the quality control unit are not in writing. Specifically, Your firm does not have established training procedures to oversee the initial and requalification of aseptic filling operators and visual inspection personnel for workshop (b) (4) units (b) (4) A. Your firm has one SOP titled QUAL116.P "Training for Manufacturing and Quality System Personnel" governing the training program in workshop (b) …
Contains “quality control unit*”Read the Form 483 →
Seqirus Vaccines LimitedInspection ended May 26, 2023 · FEI 3002806949 · Observation 1
… Your firm failed to follow procedure as documented in DOC-000134669 v8.0 Execution of Maintenance, in that quality unit was not notified and no investigation was initiated to determine impact on product since September 2020. Between April 23, 2021 - September 15, 2021, your firm manufactured and shipped formulated bulk FLUAD Quadrivalent batches to the US.
Contains “quality unit*”Read the Form 483 →
SciVac LTDInspection ended Mar 27, 2023 · FEI 3012695367 · Observation 4
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. Procedures are not established and / or followed to manage reconciliation of visual inspection personnel qualification documentation, media fill unit inspection documentation, etc. i. Your visual inspection qualification documentation does not reconcile all vials during operator qualifications. ii. Your media fill …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
FRUEH VERPACKUNGSTECHNIK AGInspection ended Mar 24, 2023 · FEI 3010363503 · Observation 4
The responsibilities and procedures applicable to the quality unit are not in writing and fully followed. Specifically, Supervisory oversight over quality/production unit operations and laboratory/production electronic system and data is deficient. For Example A. The Quality Unit lacks adequate control over the issuance of production batch records purported to be controlled under your batch issuance procedures. During the inspection, it was …
Contains “quality unit*”Read the Form 483 →
Amneal Pharmaceuticals Private Ltd.Inspection ended Dec 23, 2022 · FEI 3010254278 · Observation 16
… The Senior General Manager of Quality Assurance confirmed that the Original Equipment Manufacture's (OEM) 2016 P&ID has not been reviewed and approved by the Quality Unit. c. Change Control document number CC-AMN-21-2316, dated 1 Nov 21, required that the (b) (4) (b) (4) (b) (4) Which included a change of (b) (4) (b) (4) (b) (4) The above AHUs are used in the aseptic fill room on the (b) (4) (b) (4) As confirmed the Assistant General Manager …
Contains “quality unit*”Read the Form 483 →
Octapharma Pharmazeutika Produktionsgesellschaft m.b.H. OPGInspection ended Dec 16, 2022 · FEI 3002809097 · Observation 2
There is no assurance of effective training or accurate deviation root cause assignment for employees engaged in sampling, testing, data reporting and data review from the Quality Control Unit and Production Unit. The following deviations were reported to be due to human error or due in part to employees who were inadequately trained in the cGMP procedures. These include but are not limited to: Specifically, A. Deviation, TW#111834, dated …
Contains “quality control unit*”Read the Form 483 →
Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 7
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, a. The Preparation, approval, issue and control of Drawing/Layout, document number SOP MDP QA 00492, dated 15 Jul 2020, defines & establishes the standard procedures regarding the engineering diagrams/drawings. Section 5.1.5.8 page 5, contains language with respect to the Quality Assurance person who approves the …
Opens with FDA's citation wording for 21 CFR 211.22(d)Read the Form 483 →
Meiji Seika Pharma Co., Ltd.Inspection ended Sep 2, 2022 · FEI 3008927877 · Observation 1
Failure to have a quality unit that is independent of production and fulfills quality assurance (QA) and quality control (QC) duties. Specifically, Your written procedure Roles and Responsibilities of Operations related to GMP, 40-60-018-00-00-V17, page 10 states the QA manager is responsible review of the validation protocol and reports. Page 11 of the procedure states Validation Manager is responsible for approving the validation protocol, …
Contains “quality unit*”Read the Form 483 →
Catalent Indiana LLCInspection ended Sep 1, 2022 · FEI 3005949964 · Observation 4
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, A-SOP-03-04-001, Performance of AQL for Parenteral Inspections, states AQL sampling should be a representation of the entire batch. "During (b)(4) Inspection with (b)(4) (System 2440), if AQL …
Contains “quality control unit*”Read the Form 483 →
AnazaoHealth CorporationInspection ended Jul 29, 2022 · FEI 3011152407 · Observation 1
The quality unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred. Specifically, the firm has not been reviewing sterility test data packets from their contract testing laboratory for all drug products produced as part of their batch release process for the (b) (4) Suite since January 20, 2015 and for the (b) (4) Suite built in August 2020. Examples of drug …
Contains “quality unit*”Read the Form 483 →
Cadila Healthcare LimitedInspection ended Mar 10, 2022 · FEI 3013712903 · Observation 1
OBSERVATION 1 The written stability testing program is not followed. Specifically, the stability program is not followed to complete the testing within predefined time frame. The Quality Unit failed to test about 250 stability samples within [illegible] days as required under, "SOP for Stability Management (Document# 0317-SOP-QC-00132, Effective Date: 7/23/2021)." Examples of stability samples that were delayed testing include: Product/Material …
Contains “quality unit*”Read the Form 483 →
Cadila Healthcare LimitedInspection ended Mar 10, 2022 · FEI 3013712903 · Observation 2
… The Quality Unit failed to complete the APQRs for the following products within due period: Actual Sr. Intended Total number Product Name completion No. completion date of days delayed date f6>-(4) IInj. 1 12/19/2020 2/24/2021 67 USP mg/ml, ml 6)14) F In j. 2 USP b) mg/ml,~:> ml ~ )14) ~ In j. 3 6/8/2021 7/24/2021 46 USP, b) mg/mL,~:> mL b)(.J) I1nj.:~J 4 mg/mL, ,l mL 6f(4) IInj. ~r~ 5 mg/mL, ,CmL 12/6/2020 12/26/2020 20 b)(.J) I1nj. 6 ~Jmg/mL,,l …
Contains “quality unit*”Read the Form 483 →
Bioiberica, S.A.UInspection ended Feb 4, 2022 · FEI 1000418405 · Observation 3
The quality control unit lacks responsibility to approve all procedures which assure strength, quality, and purity of drug substances. Specifically, A. During my review of electronic HPLC data for assay testing, [illegible] encountered during analysis of drug substance, samples are re-tested until desirable results are achieved. Original test results were not reported, and no laboratory investigation procedure. Specifically during review of your …
Contains “quality control unit*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.22Responsibilities of quality control unitIn this theme's rule46
- 21 CFR 211.192Production record review6
- 21 CFR 211.113Control of microbiological contamination5
- 21 CFR 211.165Testing and release for distribution5
- 21 CFR 211.63Equipment design, size, and location2
- 21 CFR 211.100Written procedures; deviations2
- 21 CFR 211.160General requirements2
- 21 CFR 211.180General requirements2
- 21 CFR 211.25Personnel qualifications1
- 21 CFR 211.42Design and construction features1
Ask FDAgent about quality unit in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.