Skip to content

Seqirus Vaccines Limited Form 483, May 2023

FDA issued this Form 483 to Seqirus Vaccines Limited in Liverpool, United Kingdom (FEI 3002806949) at the end of a biologics inspection that ended May 26, 2023. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 26, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
May 26, 2023
Biologics · Vaccines and Allergenic Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 26, 2026
1,249 days after the inspection
Facility
FEI 3002806949
Liverpool, United Kingdom

The 2 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Failure to investigate calibration failure

    Failure to conduct investigations into unexplained discrepancies. Specifically, during the review of the calibration certificate for the (b)(4) used for the testing of the (b)(4) (b)(4) for the bulk formulated (b)(4) of Fluad. We observed that the September 2021 Calibration Certificate "As Found" data had not met the acceptance criteria for the (b)(4) measurement (b)(4). Your firm failed to follow procedure as documented in DOC-000134669 v8.0 Execution of Maintenance, in that quality unit was not notified and no investigation was initiated to determine impact on product since September 2020. Between April 23, 2021 - September 15, 2021, your firm manufactured and shipped formulated bulk FLUAD Quadrivalent batches to the US.

  2. 2

    Lack of corrective action for recurring trend

    Lack of corrective action for trends observed during the (b)(4) Bulk Drug Substance sample (b)(4). Specifically, there is an ongoing trend of investigations for (b)(4) observed in the (b)(4) sample for (b)(4) of the Fluad Monovalent Bulk Drug Substance for Influenza Vaccine. The investigation into 18 monovalent bulk drug substance batches is investigated under Master Deviation QE000436. Per Doc 000166303 V39 Determination of Sample Test (b)(4), the (b)(4) is a release specification for Fluad Monovalent Bulk Influenza Drug Substance. The Monovalent Bulk Drug Substance sample ((b)(4)) must conform to (b)(4). A. Per the BLA 125510, a criterion was not established and or specified in the approved application for (i.e., (b)(4) (b)(4) etc.). However, Doc 000077011, Control in the (b)(4), & (b)(4) Event of (b)(4) Detected in (b)(4) Containers or Sample Container, identifies (b)(4) detected during the (b)(4) (b)(4) assay as (b)(4) for the monovalent bulk drug substance. B. Per Master Deviation Investigation QE000436, sixteen (16) of eighteen (18) batches did not meet your Product Quality Specification per Doc 000188223 v13 for (b)(4) however, the (b)(4) investigation was classified as minor per Doc 000077011, Control in the Event of [illegible] in (b)(4) Containers or Sample Container and 16 are within your routine quarantine usage decision (quarantine not due to (b)(4)). Examples of Monovalent Bulk batches are as follows: (b)(4). C. The root cause (QE-000436) for the (b)(4) in the monovalent bulk drug (b)(4) (b)(4) sample has been attributed to external supplier, specifically the manufacturer of the (b)(4) with (b)(4) containers. The supplier investigation is ongoing, however there is no assurance that the Fluad Monovalent bulk is representative of the Quality Control samples taken for release testing of the monovalent drug substance batches. The firm continues to use the same supplier of the (b)(4) with (b)(4) containers as cited in the June 2017 FDA 483 for (b)(4). The corrections put in place to respond to the previous corrective action for (b)(4) in (b)(4) sample for (b)(4) have not been effective for the 2023/2024 Northern Hemisphere manufacturing campaign.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.