Skip to content

UCB Farchim SA

Chemin de la Croix-Blanche 10, Bulle, Switzerland

FEI 3005023799DUNS 481797603

Company: UCB, Inc. · Linked by exact D-U-N-S match (037480084) in FDA registration data

FDA has 5 inspections on file for UCB Farchim SA in Bulle, Switzerland (FEI 3005023799), from 2011 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling, analysis, sterilization, relabeling and repacking, through Dec 31, 2026. Its registrant, UCB, Inc. (D-U-N-S 037480084), has registered 1 other site.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2011–2024
0 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
2 of 5
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest FY2023
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Deficient QA oversight and data integrity

      Quality unit oversight over quality control operations is deficient, including laboratory and productions electronic systems and data review. A. During my review of your Empower 3 chromatography software, interrupted sequences were observed, which generated "Data Incomplete" and "Missing Data" chromatographic data. As a result, the interrupted sample injections were not adequately documented to have occurred within your quality control system, and evaluations were not performed to determine whether the interrupted test injections were within specification, if applicable. Additionally, your Quality Unit was not aware that the software has the capability to verify the incomplete data and evaluate whether the sample did run, and if so, view the chromatogram. During my review of electronic test data for HPLC and GC, I observed multiple instances of interrupted injections, which I requested to be verified (brought back), for further evaluation. In addition, test runs appeared to have been manually interrupted via a "user abort" function, which, like "Data Incomplete" and "Data Missing" interruptions, your firm does not document and/or trend. This discrepancy in your firm's ability to review, document, and investigate all electronic data is a gap in your firm's Data Integrity Program. B. There is no adequate data integrity program in place to include a statistically sound comprehensive review of all electronic data by the Quality Assurance Unit for standalone and network systems, to ensure completeness, consistency, and accuracy of all chromatographic and non-chromatographic electronic data generated by the Quality Control Laboratory. Specifically, per your firm's procedure, only a [illegible] analyst verifies laboratory work, after which the Quality Assurance Unit confirms QC review. No electronic data is reviewed by the Quality Assurance unit, whether batch to batch, or an established time frame. C. Your Quality Unit lacks adequate control over electronic records generated in support of quality operations. Approximately [illegible] personnel from QA and QC have the capability to delete data on their desktops, after which the file [illegible] vanishes from the desktop, not even available for restoration and review in the recycle bin. During the walkthrough of the inspection on 06/27/2023, I observed a QA personnel delete a recently issued manufacturing batch records on their desktop following your firm's procedure, after which the recycle bin continued to be clear, showing no recent deletes. After further review, your firm's IT team was able to determine that name of files deleted are available dating back 6 months, however documents are not able to be restored. D. The Quality Unit lacks adequate control over issuance of manufacturing batch records which are purported to be controlled by your quality unit under SOPO11207, titled "Edition Des Blank Batch Record", effective date 03/15/2022. Manufacturing batch records issued to the production unit during the inspection did not appear to be adequately controlled, considering that there is no unique identifier on issued documents to prevent additionally copies from being made outside your firm's document control system.

    2. Observation 2

      Inadequate computer systems controls

      Appropriate controls are not exercised over computers or related systems to assure that changes in laboratory control records or other records are instituted only by authorized personnel. GMP related computerized systems and equipment have not been validated/qualified to demonstrate the suitability of computer hardware and software to perform assigned tasks. For example, your firm appears to have performed Performance Verification for Empower 3 software, however the verification docs do not evaluate the consistent performance of the software/equipment over a specified period and operating environment. During my review of your Empower 3 chromatography software, interrupted sequences were observed, which generated "Data Incomplete" and "Missing Data" chromatographic data. Your firm has not demonstrated to fully understand the different types of communication errors and circumstances which may lead to a "Data incomplete" or "Missing Data" chromatography considering the relationship between the Empower application and database server, Empower RDS servers, LAN cables, Empower LAC/Es, and the instruments connected to LAC/Es.

    Show observations 3 to 4
    1. Observation 3

      Analytical test methods not validated

      The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented. Your firm has not performed analytical method transfers for the following active pharmaceutical ingredients: [illegible] Additionally, standard and sample solution stability has not been established by your firm as part of the HPLC method validation reports and testing operations for [illegible].

    2. Observation 4

      Missing warehouse/materials procedures

      Written procedures are lacking which describe in sufficient detail the handling of components. Procedures applicable to the warehouse facility operations, with respect to material receipt activities are not in writing in your firm's material receipt procedure SOP 001453, titled "Flux de reception" (Reception Flow), effective date [illegible]. During my walkthrough of your material receipt area on 06/26/2023, [illegible] observed [illegible] placed on bulk large bags for raw material [illegible] (batch # [illegible]). Per your firm's warehouse supervisor: [illegible]. This practice of using [illegible] to indicate not to perform a specific activity, such as [illegible], is not written in your firm's material receipt procedure.

  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Component addition checked by 2nd person

      Each component is not added to a batch by one person and verified by a second person.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Jul 4, 2023VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. FY2023FDA-FOIA-2023-7607Form 483Closed
    2. Oct 10, 2023FDA-FOIA-2023-8883Form 483Closed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-7618Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 5 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3005023799, one row per refused product line.

1 refusal on 2019-09-19 · charged UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2019-09-19

    LEVOCETIRIZINE DIHYDROCHLORIDE61XAA51

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-2936185-3/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, labeling, analysis, sterilization, relabeling, repacking
Registration runs through
Dec 31, 2026
Registrant
UCB, Inc.D-U-N-S 037480084

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names UCB, Inc. (D-U-N-S 037480084) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • UCB Pharma S.A.Braine-L'Alleud, Belgium · FEI 30039093568 inspections8latestJun 4, 2026VAINone on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3005023799 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3005023799. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.