Monitoring cleanrooms and the people in them: viable and nonviable air sampling, settle and contact plates, glove and fingertip samples, and the results that should trigger action. FDAgent finds 179 such observations in 116 Form 483s issued to 109 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
179
Each quoted below
Form 483s
116
Posted by FDA
Facilities
109
Distinct FEIs
Most recent
Sep 28, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 64 in 2026

Environmental monitoring observations in Form 483s by inspection year
YearObservations
20082
20090
20100
20110
20122
20130
20142
20152
201611
20179
20186
20195
20201
202114
202214
202313
202411
202523
202664

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.42(c)(10)(iv)

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“environmental monitoring” · “viable” · “nonviable” · “non viable” · “settle plate*” · “contact plate*” · “personnel monitoring” · “fingertip*” · “glove print*” · “glove sampl*” · “particle count*” · “air sampl*” · “surface sampl*” · “EM program*” · “EM sampl*” · “EM data” · “EM excursion*” · “EM result*” · “EM plate*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 179 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 1

    … The tools are stored in the grade B area and are not part of the environmental monitoring or (b)(4) program. The tools currently in use were sterilized 09Oct2025. 4. Risk assessment for BI locations, to determine the hardest to reach locations for (b)(4) sterilization has not been performed. Procedures do not specify or document the exact location of the BI placement during validation. Only general locations are specified. For an example from the …

    Contains “environmental monitoring”Read the Form 483 →

  2. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 3

    … cycle, or touching equipment during the (b)(4) were observed (b)(4) is (b)(4) are not put in place until after the (b)(4) (b)(4) including (b)(4) packages, settle plates, Various items were observed on the floor of the (b)(4) active air equipment/lid, cleaning hose and tools. There is no evidence that (b)(4) penetrates these areas. The justification for BI location, as well as the (b)(4) validation, does not consider the ancillary …

    Contains “settle plate*”Read the Form 483 →

  3. Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 4

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Environmental Monitoring 1. Adequate risk assessment could not be provided for changing viable surface monitoring from RABs, are (b)(4) located in the (b)(4) to (b)(4) These (b)(4) for the (b)(4) used to handle settle plates during environmental monitoring. 2. Recovery studies have not been performed that show using one swab (b)(4) of a (b)(4) …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  4. Fujifilm Diosynth Biotechnologies USA Inc.Inspection ended Mar 27, 2026 · FEI 3000718852 · Observation 1

    … Currently, environmental monitoring (EM) of these conditions is limited to major activities such as (b) (4), passaging of (b) (4), and bulk fill operations. You do not have EM data to support "at rest" conditions. Furthermore, you have not performed a risk assessment or study to verify that your EM locations used for current sampling of these environments are suitable for collecting data representative of the actual conditions. Additionally, you …

    Contains “environmental monitoring”Read the Form 483 →

  5. Fujifilm Diosynth Biotechnologies USA Inc.Inspection ended Mar 27, 2026 · FEI 3000718852 · Observation 2

    … [illegible] PR Mold in (b) (4) viable air | Cladosporium allicinum/ No root cause was identified, and 327905 | sites. cladosporioides/ cucumerinum/ no remediation was performed. herbarum/ macrocarpum/ phaenocomae/ ramotenellum PR Mold recovery in batch Aureobasidium melanogenum No root cause identified. 380876 | (b) (4) during (b) (4) inadequate corrective actions. Post Hold. Batch was ultimately rejected. PR Mold recovery in batch Paenibacillus …

    Contains “viable”Read the Form 483 →

  6. Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 3

    … Your firm's environmental monitoring program does not address the following: In-process monitoring of BSC on March 18, 2026, during Day (b) (4) manufacturing activities for Sipuleucel-T batch number (b) (4) did not include sampling of the (b) (4) of the BSC as per instructions in procedure SOP-11386.27 entitled "In-Process Environmental Monitoring at ...... Manufacturing Facilities", effective October 4, 2024. On March 18, 2026, it was observed …

    Contains “environmental monitoring”Read the Form 483 →

  7. Bausch and Lomb IncorporatedInspection ended Mar 20, 2026 · FEI 1000113778 · Observation 2

    … While changing the environmental monitoring plates within the Grade A area of Filling Line# B the operator was seen moving quickly and reaching over areas where open and exposed empty bottles were located. iv. During an intervention of removing a stuck empty bottle, we observed the operator manipulate the forceps at the end that comes in contact with the open container. Additionally, the operator abruptly manipulated a jammed bottle in a manner …

    Contains “environmental monitoring”Read the Form 483 →

  8. Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 2

    Computerized systems used for the collection and analysis of quality data have not been validated. Specifically, The Excel spreadsheet used for environmental monitoring data collection, trending, and analysis has not been validated. Your firm has not demonstrated that this system is accurate, reliable, and capable of ensuring the integrity of the data generated and maintained within your environmental monitoring program.

    Contains “environmental monitoring”Read the Form 483 →

  9. Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 3

    Flow of materials and equipment is not designed to prevent contamination. Specifically, (b)(4) Room is a Grade (b)(4) with (b)(4) for movement of (b)(4) [illegible] the warehouse receiving area (b)(4) warehouse (b)(4) storage area (b)(4) to the (b)(4) (b)(4) (Room (b)(4)) the manufacturing (b)(4) (Grade) for (b)(4) of (b)(4) (b)(4). Your firm's environmental monitoring data for Room (b)(4) shows consistent mold recoveries (% of all (b)(4) mold …

    Contains “environmental monitoring”Read the Form 483 →

  10. Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 4

    … Environmental Monitoring of the BSC is less stringent during sampling than routine EM. During (b)(4) (b)(4) activities on 03/15/2026, EM monitoring of the BSC in Room (b)(4) was only conducted with [illegible] sample collection. (b)(4) routine monitoring of this BSC under dynamic conditions (normal or simulated) requires (b)(4) settle plates, (b)(4) plate samples, (b)(4) settle plates during (b)(4) active air sampling, and non-viable particulate …

    Contains “environmental monitoring”Read the Form 483 →

  11. SCA Pharmaceuticals LLCInspection ended Mar 13, 2026 · FEI 3013736415 · Observation 1

    … These organisms are either spore forming, or non-spore forming organisms recovered from either gloved fingertip, sleeve monitoring, active air, and/or passive air samples. Of the approximate 46 excursions initiated affecting multiple product batches including Phenylephrine HCL 100mcg, Oxytocin, Sucinylchlorine Chloride, Fentanyl Citrate, Labetalol, Rocuronium Bromide, Hydromorphone HCL, Diltiazem DCL and a Media Fill batch, [illegible] been …

    Contains “fingertip*”Read the Form 483 →

  12. Hospira, Inc.Inspection ended Mar 10, 2026 · FEI 1925262 · Observation 2

    … There is no viable environmental monitoring at they stopper bowl location, with the total non-viable particle cone at an elevated level above the work surface. b. The ge room wall mounted signage, holder indicating Code and Lot identification creates a gap between the wall and the holding device, a cleaning challenge. c. Your ge used in gq drug product manufacture are near [illegible]. The gg for wo is the room containing the E. You fail to have …

    Contains “viable”Read the Form 483 →

  13. Hospira, Inc.Inspection ended Mar 10, 2026 · FEI 1925262 · Observation 4

    Observation 4: Procedures in ge drug product manufacture are deficient. Specifically, a. Your firm lacks adequate procedures and training for microbiological plate reading, resulting in inconsistent practices among laboratory personnel. There are no written procedures or documented training records that define the methodology for reading environmental monitoring settle plates and touch plates for microbial growth. On 5 March 2026, laboratory …

    Contains “environmental monitoring”Read the Form 483 →

  14. Eugia Pharma Specialities LimitedInspection ended Feb 27, 2026 · FEI 3011960448 · Observation 1

    OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, 1. Environmental and personnel monitoring are not appropriately established. The aseptic connection for connecting the (b)(4) vessel for L (b)(4) was performed within the LAF on line (b)(4) July 2025 with bacterial alert and action limits of (b)(4) and (b)(4), respectively. The area …

    Contains “personnel monitoring”Read the Form 483 →

  15. RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 2

    … Only operators' fingertips are monitored, not the rest of the fingers or hands. 5. To open the inert-chamber door between the (b)(4) and the (b)(4), the operator touched four locations: the (b)(4) door button to unlock the door, the door handle to manually open it, the other side of the door facing the (b)(4), and the tray above (b)(4) to bring material into the (b)(4). Only the (b)(4) door button is monitored; the other three locations are not. …

    Contains “fingertip*”Read the Form 483 →

  16. RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 3

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. The firm's environmental monitoring and personnel monitoring procedures are inadequate. For example: 1. Your firm failed to analyze raw Environmental Monitoring data for patterns (e.g., increasing CFUs) that indicate a loss of control in aseptic areas. Data trending is not performed and compiled (b)(4) in accordance with …

    Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →

  17. RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 4

    … A review of the firm's environmental monitoring excursions list (EME (b)(4)) for the period from 05/20/2025 to 01/20/2026 revealed that approximately 55 of 113 EME investigations remain open (37 in ISO 5 areas) without adequate investigation, with many investigations for excursions dating back to 10/06/2025 (n=18) not yet initiated. Multiple batches were released to market with unresolved excursions. For example: EME-2025-046: On 11/11/2025, an …

    Contains “environmental monitoring”Read the Form 483 →

  18. Dreyer's Grand Ice Cream, Inc.Inspection ended Feb 20, 2026 · FEI 2939502 · Observation 1

    … procedures, and Production Listeria Treatment Form (also called Listeria clean)) were not implemented to control Listeria contamination because your environmental monitoring records continue to show confirmed positive for L. monocytogenes in zones [illegible] throughout the production and auxiliary areas as summarized in the table below. Zone [illegible] may be 1.5 feet away from exposed products (eg. (b)(4) (b)(4) cart) and Zone [illegible] may …

    Contains “environmental monitoring”Read the Form 483 →

  19. Biomylz Private LimitedInspection ended Feb 9, 2026 · FEI 3013697420 · Observation 1

    … limited to, executed production batch records; media preparation, incubation, and sterilization cycle logbook pages; finished product sample collection forms; environmental monitoring sample forms; and change control log forms. B. The Incubation Usage Log, Book Number (b)(4) Reference SOP: QCD-M/007 & III, contained (b)(4) entries (Serial Numbers (b)(4) through (b)(4)) that were signed by the analyst (QC Microbiologist) and verified by a second …

    Contains “environmental monitoring”Read the Form 483 →

  20. SNJ Labs Private Ltd.Inspection ended Feb 6, 2026 · FEI 3026587575 · Observation 6

    … for (b) (4) (lot (b) (4) and (b) (4) (vendor lot (b) (4) lots that were received and currently used for microbiological testing of finished products, environmental monitoring and water testing. Furthermore, your QC Manager confirmed that method verification was not performed for growth promotion studies. c. Your firm failed to initiate laboratory incidents when analysts did not correctly follow HPLC processing methods to analyze (b) (4) assay …

    Contains “environmental monitoring”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about environmental monitoring in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.