SCA Pharmaceuticals LLC
Windsor, Connecticut, United States
FEI 3013736415
FDA has 4 inspections on file for SCA Pharmaceuticals LLC in Windsor, Connecticut (FEI 3013736415), from 2019 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Oct 20, 2023. No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 4, 2019–2026
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- 2 posted 483s not matched to an inspection
- Requested under FOIA
- 1 request, latest Oct 8, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetPosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate microbiological contamination controls
Procedures designed to prevent microbiological contamination are not established and followed. Specifically, A. Your firm has initiated approximately 46 Excursion (EXC), representing reports for microorganisms recovered from the ISO-5 critical zone in the Laminar Flow Hoods where sterile drug products are compounded. Since December 2024 organisms recovered included Staphylococcus species (epidermidis, hominis, capitis, haemolyticus), Bacillus simplex (clausii, infantis, circulans), Corynebacterium tuberculostearicum, Micrococcus luteus, and other organisms such as Kocuria, Peribacillus, Paenibacillus, Fictibacillus, Streptomyces, Cladosporium, Sphigmonas and Penicillium citrinum. These organisms are either spore forming, or non-spore forming organisms recovered from either gloved fingertip, sleeve monitoring, active air, and/or passive air samples. Of the approximate 46 excursions initiated affecting multiple product batches including Phenylephrine HCL 100mcg, Oxytocin, Sucinylchlorine Chloride, Fentanyl Citrate, Labetalol, Rocuronium Bromide, Hydromorphone HCL, Diltiazem DCL and a Media Fill batch, [illegible] been rejected and [illegible] has been released. Product Name Sample Personnel Method Fentanyl Citrate Compounder 1 (b)(4) (b)(4) 2 mcg/mL Bupivacaine HCl 0.1% in 0.9% Sodium Chloride 250 mL Bag, Lot: 1225059964 BUD: 24 SEP 2025 (Intrathecal) Aseptic Assistant (b)(4) (b)(4) * NIA = the organism was unable to be subcultured; therefore, no identification was performed. B. Compounders and Aseptic Assistants were observed not using slow and deliberate movements in the ISO-5 Laminar Flow Hoods or during compounding activities on [illegible], not holding their hands and arms in a position within the manufacturing workspace to minimize potential air turbulence. Furthermore, Compounders and Aseptic Assistants were observed using their feet to kick garbage receptacles, power cords on the floor and non-viable probes throughout the ISO-7 manufacturing area. These actions can potentially aerosolize particles and microorganisms from the floor, which can then draw into the ISO-7 clean room and subsequently into the ISO-5 Laminar Flow Hoods. C. Your firm utilizes the (b)(4) air sampling collection device to perform air sampling in the Laminar Air Flow Hoods. You have not adequately determined that placing the unit [illegible] while conducting the test does not violate first air principles by pushing air deflected from the unit into the critical workspace and creating potential reflux. D. Your operators were observed utilizing sterile goggles that utilize the (b)(4). You have not provided an adequate rationale to support the use of these goggles in the sterile core. The sterile goggles have [illegible] potential particulates from operator's skin to egress into the surrounding environment. The sterile goggles are part of the sterile gowning used for operators in your clean room and when preparing products intended to be sterile in your [illegible]. E. Operators conducting cleaning were observed using materials prepared in the ISO-7 clean room such as lint free dry wipes saturated in buckets [(b)(4)] wipes to clean inside the laminar flow hood and outside of the hood.
- Observation 2
Failure to investigate particulate discrepancies
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, • Your firm failed to identify the root cause for particulate contamination in products intended to be sterile and failed to implement effective corrective and preventive actions to prevent recurrence. These deviation investigations have been described as Investigation Major Particulate Matter DRL Threshold Exceedance, 100% Visual Inspection Particulate Matter Threshold Exceedance, AQL Failure, and Major DRL Particulate Matter Threshold Exceedance. Since December 2024, your firm has initiated approximately 110 deviation investigations due to visual inspection failures for particulates. The majority were initiated due to contaminates observed that present as material found on the plunger, floating particulate, or adhered to the stopper barrel. Despite this recurring pattern of contamination, your firm has not: • Conducted a thorough investigation to determine the definitive root cause(s) of particulate failures. • Implemented corrective and preventive actions (CAPA) that address the underlying cause(s) of particulate contamination. • Demonstrated the effectiveness of any corrective actions taken to prevent the continued occurrence of intrinsic particulates. • Adequately justified the classification of "Major" for particulate contamination. The repeated occurrence of intrinsic particulate failures without adequate investigation and effective CAPA demonstrates a failure to maintain your manufacturing process in a state [illegible].
Show observation 3
- Observation 3
Inadequate cleaning/disinfectant procedures
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing. Your firm's VAL-24-076-FR, Disinfectant Efficacy Study for the Connecticut Facility Located at 755 Rainbow Road, Windsor, CT 06095, Rev. 1 established a (b)(4) dwell time when cleaning with (b)(4) to disinfect all classified areas. The following deficiencies were noted in VAL-24-076- Rev. 1, December 2024. 1. No evaluation of other organisms other than Bacillus altitudinis/pumilus/safensis. The firm has recovered other spore forming organisms from the ISO-5 sterile compounding core including: Cladosporium and related organisms. According to the manufacturer's instructions for (b)(4), [illegible] is required to effectively use (b)(4) for reduction in the presence of bacteria, mold and other spore forming organisms.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Written procedures not established/followed
Written procedures are not for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Show 2 more citations
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written.
- FDCA 503B(a)(10)(A)
Drug product labels, fails to include
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Lack of quality control unit
There is no quality control unit.
Show 5 more citations
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.
Written procedures not established/followed
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Oct 8, 2026. It asked for a Form 483.
Inspection ending Dec 20, 2024VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Oct 8, 2026FDA-FOIA-2026-9820Form 483· 1 of 3 sitesOpen
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review3 of 3
- 21 CFR 211.42Design and construction features2 of 3
- 21 CFR 211.63Equipment design, size, and location2 of 3
- 21 CFR 211.67Equipment cleaning and maintenance2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
Show all 12
- 21 CFR 211.103Calculation of yield1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.188Batch production and control records1 of 3
- 21 CFR 211.198Complaint files1 of 3
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013736415 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013736415. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.